Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search

Specialist in battery-backed safety power supply: BSV systems, UPS systems, safety lighting and service.

AM

Amandus Dierks GmbH

DelmenhorstNew on Amplifa

1919Founded
DelmenhorstLocation
Marc WestermannManagement

About Amandus Dierks

Amandus Dierks GmbH has been active in the field of battery-backed power supply since 1919 and has specialized in professional emergency power supply for safety-critical systems. The product range includes BSV systems for medically used areas (Medi-Intensiv for 230V consumers, Medi-Lux for 24V operating lights), UPS systems from 400VA to 6,400kVA as well as its own safety lighting brand. With the modular UPS line Flex Guard, introduced in 2024, the company offers scalable systems with double-converter technology from 10kVA to 2,000kVA. In addition to planning and delivery, Amandus Dierks offers manufacturer-independent maintenance, commissioning with capacity testing in accordance with VDE 0510-2 as well as repair of systems from many manufacturers. The products are used in hospitals, data centers, industrial and process applications as well as public buildings. The owner-managed company is headquartered in Delmenhorst, Lower Saxony.

Site
Delmenhorst
Processes
Medi-Lux: Safety power supply for 24V operating lights (max. lamp output 430–4180 W), Plug & Play UPS systems (400VA to 3kVA, Off-Line/Line-Interactive/Online), Monoblock UPS systems (3.3kVA to 6,400kVA floor-standing enclosure, 3.3–10kVA in 19" enclosure), Modular UPS systems for 19″ racks (3 to 240 kW), Safety lighting, Manufacturer-independent maintenance (inspections, preventive maintenance, emergency repairs), Professional commissioning incl. capacity tests in accordance with VDE 0510-2, Manufacturer-independent maintenance
Materials
Lead battery, Lithium battery, AGM battery, Gel battery, FLA battery, Pb battery cells, NiCd battery cells, Lead battery (AGM, Gel, FLA)
Certificates
DIN VDE 0558-507 (BSV), DIN VDE 0100-710 (BSV), IEC/EN 62040-3 VFI-SS-111 (UPS), Capacity testing in accordance with VDE 0510-2
Founded
1919
Industries
Hospitals / Healthcare, IT (data centers, network infrastructure), Industry / Process applications, Public buildings, Electrical installation / Building services planning, Hospitals / Healthcare (medically used areas)
  1. 01

    Consulting & planning for building services planners and electrical contractors

  2. 02

    Project engineering & product selection

  3. 03

    Delivery & installation

  4. 04

    Commissioning incl. capacity testing in accordance with VDE 0510-2

  5. 05

    Maintenance, remote maintenance & 24h hotline

  6. 06

    Repair, spare parts service & old battery disposal

Products & Battery Technologies

Pb

Lead battery (AGM, Gel, FLA)

Proven battery technology for UPS and BSV systems, among others in accordance with DIN VDE 0558-507 with 25 % capacity reserve.

Li

Lithium battery

Alternative battery option for Plug & Play and other UPS systems.

NiCd

NiCd battery cells

Battery cells for the Medi-Lux safety power supply of operating lights.

Locations

Delmenhorst

DE

Headquarters with planning, service and sales

Materials
UPS & BSV systems, battery technologies
  • Flex Guard UPS module cabinets (10–2,000 kVA)
  • Medi-Intensiv BSV systems (5–80 kVA)
  • Medi-Lux (24V operating lights)

Industries

Hospitals / HealthcareIT (data centers, network infrastructure)Industry / Process applicationsPublic buildingsElectrical installation / Building services planningHospitals / Healthcare (medically used areas)IT (data centers, IT system houses, network infrastructure)

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Engineering–––––
Engineering–––––
Medi-Lux: Safety power supply for 24V operating lights (max. lamp output 430–4180 W)Engineering–––––
Plug & Play UPS systems (400VA to 3kVA, Off-Line/Line-Interactive/Online)Engineering–––––
Monoblock UPS systems (3.3kVA to 6,400kVA floor-standing enclosure, 3.3–10kVA in 19" enclosure)Engineering–––––
Modular UPS systems for 19″ racks (3 to 240 kW)Engineering–––––
Engineering–––––
Safety lightingEngineering–––––
Manufacturer-independent maintenance (inspections, preventive maintenance, emergency repairs)Assembly–––––
Professional commissioning incl. capacity tests in accordance with VDE 0510-2Testing–––––
Assembly–––––
Engineering–––––
Engineering–––––

6 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Flex Guard UPS module cabinetAmandus Dierks GmbH MOC02x020–10–40kVA, 1–2 power modules, 4-way parallel-capable (up to 160kVA), 19" installation–Delmenhorst
Flex Guard UPS module cabinetAmandus Dierks GmbH MOC04x020–10–80kVA, 1–4 power modules, 8-way parallel-capable (up to 640kVA)–Delmenhorst
Flex Guard UPS module cabinetAmandus Dierks GmbH MOC06x020–10–120kVA, 1–6 power modules, 5-way parallel-capable (up to 720kVA)–Delmenhorst
Flex Guard UPS module cabinetAmandus Dierks GmbH MOC04x030–30–120kVA, 1–4 power modules of 30kVA each, 8-way parallel-capable (up to 960kVA)–Delmenhorst
Flex Guard UPS module cabinetAmandus Dierks GmbH MOC06x030–30–180kVA, 1–6 power modules of 30kVA each, 5-way parallel-capable (up to 900kVA)–Delmenhorst
Flex Guard UPS module cabinetAmandus Dierks GmbH MOC10x030–30–300kVA, 1–10 power modules of 30kVA each, 3-way parallel-capable (up to 900kVA)–Delmenhorst

Additional services

Manufacturer-independent maintenanceCommissioning incl. capacity testing in accordance with VDE 0510-2Spare parts serviceOn-site serviceRemote maintenance24h/7 days telephone hotlinePlanning and consulting for building services planners and electrical contractorsBattery replacement and disposal of old batteriesUPS systems for rent

Quality & Standards

Commissioning is carried out including capacity tests in accordance with VDE 0510-2; BSV systems comply with DIN VDE 0558-507 and DIN VDE 0100-710, and the Flex Guard system complies with IEC/EN 62040-3 (VFI-SS-111). Systems include automatic function tests with logging as well as digital test books.

EvidenceDelmenhorst
DIN VDE 0558-507 (BSV)
DIN VDE 0100-710 (BSV)
IEC/EN 62040-3 VFI-SS-111 (UPS)
Capacity testing in accordance with VDE 0510-2

Company History

  1. 1919

    Amandus Dierks founds the company (November 1919)

  2. 1952

    Works contract with NIFE for Bremen and northern Lower Saxony; Amandus Dierks remains 100% independent

  3. 1959

    Product offering expanded to include additional battery types as well as chargers and power converters

  4. 1978

    Start of hospital emergency power supply systems (BEV systems)

  5. 1980

    First EMP (electronic reporting and testing system) on the market

  6. 1998

    NIFE is renamed Kaufel and becomes part of Thomas & Betts Corporation

  7. 2012

    ABB acquires Thomas & Betts; Kaufel becomes ABB Kaufel in 2016

  8. 2016

    Company homepage goes online

  9. 2020

    Own safety lighting brand launched on the market

  10. 2022

    Acquisition of LED luminaire manufacturer Sonertec as a 100% subsidiary

  11. 2024

    Market launch of the modular UPS line Flex Guard

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo