AWT Anlagenschutz und Wassertechnik GmbH was founded in 1996 and specializes in damage prevention in water-carrying systems. The company from Ebreichsdorf offers analysis, cleaning and treatment for heating systems, drinking water systems, cooling circuits and antifreeze solutions. Its service portfolio includes system cleaning and flushing technology, heating and cooling water treatment, drinking water analysis and disinfection with chlorine dioxide systems (DK-DOX, CLO-CONT), legionella service, biofilm management and antifreeze management. An in-house laboratory performs standard-compliant analyses according to ÖNORM H 5195-1, with results documented in a digital laboratory database. Under its own brand pH-Optima, AWT also offers products for corrosion protection, water softening and water treatment. Customers include private households, plumbers, property management companies, boiler manufacturers, industrial operators, hospitals, hotels, schools and sports facilities in Lower Austria, Vienna and Burgenland.
- Site
- Ebreichsdorf
- Processes
- System cleaning and flushing technology for heating, cooling and antifreeze systems, Mechanical flushing technology for removal of sludge and particles, Chemical cleaning of magnetite and corrosion residues, Filtration for system fluids, Standard-compliant heating water treatment according to ÖNORM H 5195-1, Antifreeze analysis and optimization of the glycol mixture, Biofilm management with chlorine dioxide for drinking water and cooling systems, Antifreeze filling with special tank truck (reference project Hofburg)
- Materials
- Heating water, Drinking water, Glycol (antifreeze agent), Coolant/cooling water, Hot water, Cooling water
- Certificates
- ÖNORM H 5195-1 (heating water treatment), ÖNORM B 5019 (drinking water hygiene)
- Founded
- 1996
- Industries
- Households, Plumbers, Property management companies, Commercial and industrial, Hospitals and care facilities, Hotels and gastronomy
- 01
Analysis and sampling (AWT analysis kit or on site)
- 02
Laboratory analysis according to ÖNORM
- 03
Assessment and consulting
- 04
Cleaning, flushing technology and disinfection
- 05
Water treatment and product dosing (pH-Optima)
- 06
Documentation and follow-up inspection
Materials & Media
Heating water
Analysis, treatment and conditioning according to ÖNORM H 5195-1 for corrosion-free heating systems.
Drinking water
Filtration, softening and disinfection to ensure hygienic standards.
Glycol (antifreeze agent)
Analysis and optimization of the glycol mixture for antifreeze systems.
Cooling water
Biofilm management and treatment for cooling circuits and recooling units.
Hot water
Legionella testing and disinfection in hot water systems.
Locations
Ebreichsdorf
ATHeadquarters with in-house laboratory, service operations and chlorine dioxide systems
- Materials
- Heating water, drinking water, glycol, cooling water, hot water
- Chlorine dioxide disinfection system DK-DOX
- Chlorine dioxide disinfection system CLO-CONT
- Flushing technology
- Filtration systems
- Laboratory analysis with laboratory database
- Special tank trucks for antifreeze filling
Services & Systems



Inside the production



Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| System cleaning and flushing technology for heating, cooling and antifreeze systemsTesting | – | – | – | – | Heating water, Refrigeration water, Glycol antifreeze solutions |
| Mechanical flushing technology for removal of sludge and particlesTesting | – | – | – | – | Heating water |
| Chemical cleaning of magnetite and corrosion residuesTesting | – | – | – | – | Heating water |
| Filtration for system fluidsTesting | – | – | – | – | Heating water, Drinking water |
| Standard-compliant heating water treatment according to ÖNORM H 5195-1Testing | – | – | – | – | Heating water |
| Antifreeze analysis and optimization of the glycol mixtureTesting | – | – | – | – | Glycol |
| Biofilm management with chlorine dioxide for drinking water and cooling systemsTesting | – | – | – | – | Drinking water, Coolant |
| Antifreeze filling with special tank truck (reference project Hofburg)Testing | – | – | – | – | Glycol |
| Chemical disinfection with chlorine dioxide (DK-DOX, CLO-CONT)Testing | – | – | – | – | Drinking water |
| Thermal disinfectionTesting | – | – | – | – | Drinking water |
| Legionella remediation (testing, root cause analysis, disinfection, biofilm management,Testing | – | – | – | – | Drinking water, Hot water |
| Softening of drinking waterTesting | – | – | – | – | Drinking water |
| Heating water analysis (pH value, conductivity, hardness level, residual hardness,Testing | – | – | – | – | Heating water |
| Drinking water analysis (legionella, coliform bacteria, E. coli, enterococci, PseudomonasTesting | – | – | – | – | Drinking water |
| Antifreeze analysis (glycol concentration, frost protection level, inhibitor status)Testing | – | – | – | – | Glycol |
| Water treatment and system care (own brand pH-Optima: corrosion protection, softening)Testing | – | – | – | – | Heating water, Drinking water |
6 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Chlorine dioxide disinfection system | DK-DOX | – | – | – | Ebreichsdorf |
| Chlorine dioxide disinfection system | CLO-CONT | – | – | – | Ebreichsdorf |
| Special tank truck for antifreeze filling | – | – | – | – | – |
| Flushing technology / mechanical flushing technology | – | – | – | – | – |
| Filtration systems | – | – | – | – | – |
| Laboratory analysis (AWT's own laboratory with laboratory database) | – | – | – | – | Ebreichsdorf |
Additional services
Reference customers
Quality & Standards
AWT works according to ÖNORM requirements such as ÖNORM H 5195-1 and ÖNORM B 5019 and documents all measured values in a standard-compliant manner in its own laboratory. Analysis results are available within five working days via the digital laboratory database.
| Evidence | Ebreichsdorf |
|---|---|
| ÖNORM H 5195-1 (heating water treatment) | |
| ÖNORM B 5019 (drinking water hygiene) |
History
- 1996