
Specialist for reactive power compensation, UPS systems, power quality and energy data management in Austria.

B & W TechComp Handels GmbH / B & W Services GmbH
St. Pölten · Bruck an der GlocknerstraßeNew on Amplifa
Specialist for energy data management and electrical power quality
B & W is an Austrian specialist company founded in 1992 out of a two-man vision, dedicated to reactive power compensation, uninterruptible power supply (UPS systems), electrical power quality and energy data management. The company offers consulting, calculation, logistics, installation as well as service and maintenance from a single source. The product portfolio includes online UPS systems from 1 kVA to 800 kW (monoblock, rack, tower, cabinet and modular systems with N+1 redundancy), outdoor UPS systems, reactive power compensation units from 5 to 400 kVAr in floor-standing cabinet, wall-mounted cabinet and modular designs, reactive power controllers, filter solutions such as mains, harmonic and inverter output filters, energy meters and measuring devices from EMU and KBR as well as mobile power quality measuring devices from A-Eberle. Measurement services are performed with wired connections in the low- and medium-voltage range, in the time and frequency domain from DC voltage up to 20 MHz, in line with standards such as EN 50160. Customers come from industries such as chemicals, automotive supply industry, food industry, steel industry, printing, tourism and public infrastructure. The headquarters is in St. Pölten, and a second location in Bruck an der Glocknerstraße covers western Austria.
- Site
- St. Pölten, Austria
- Processes
- Reactive power compensation, Energy management / energy data management, UPS systems (uninterruptible power supply), Electrical power quality / power quality (active and passive filters), Energy efficiency measurement according to ISO 50001, Service, maintenance and inspection of UPS systems and reactive power compensation, Consulting, Measurement services (wired, EN 50160)
- Materials
- UPS Systems, Reactive Power Compensation, Electrical Power Quality / Filters, Energy Data Management, Measurement Services Power Quality
- Certificates
- Measurements according to EN 50160, Energy efficiency measurement according to ISO 50001, MID approval energy meters
- Industries
- Chemicals, Automotive supply industry, Food industry, Meat and sausage processing, Steel industry, Printing
- 01
Consulting and energy analysis
- 02
Measurement services / measurement (wired, EN 50160)
- 03
Calculation and concept
- 04
Logistics
- 05
Installation and commissioning
- 06
Service and maintenance
- 07
Support
Products and Systems
UPS Systems
Online UPS systems from 1 kVA to 800 kW as monoblock, rack, tower, cabinet and modular systems as well as outdoor UPS units for harsh environmental conditions.
Reactive Power Compensation
Floor-standing cabinets, wall-mounted cabinets, fixed stages and compensation modules from 5 to 400 kVAr with detuning factors of 5.5 to 14 %.
Electrical Power Quality / Filters
Active, passive and hybrid harmonic filters as well as mains, sine, dU/dt filters and motor chokes for improving power quality.
Energy Data Management
Energy meters with MID approval (EMU, KBR), data loggers, load management and visualization of energy flows down to individual consumers.
Measurement Services Power Quality
Mobile measuring devices (A-Eberle PQ-Box series) for measurements in the time and frequency domain from DC voltage up to 20 MHz.
Locations

St. Pölten
ATHeadquarters, technical sales, service and logistics
- Materials
- UPS systems, reactive power compensation, power quality filters, energy data management
- Online UPS Convert II (1-10 kVA)
- Modular UPS Wisus-MC/M-E/M-S (30-800 kW)
- UPS Rack WP-R / Tower WP-T / Cabinet WP-S (25-300 kW)
- Outdoor UPS Atrox and FXM (350-2000 W)
- A-Eberle PQ-Box 300/200/150/50
- Mains filters up to 630 A
- Reactive power compensation multicab-r/f (5-400 kVAr)
- EMU energy meters Professional II (MID)
- KBR Multimess / Multisio measuring devices
- Switched-mode power supplies E-, EP-, EV-, Z-, ZPNW series
Bruck an der Glocknerstraße
ATWestern location: technical sales, service and maintenance
- Materials
- Reactive power compensation, UPS systems
Solutions and Systems





Inside the production







Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Reactive power compensationEngineering | – | – | – | – | – |
| Energy management / energy data managementEngineering | – | – | – | – | – |
| UPS systems (uninterruptible power supply)Engineering | – | – | – | – | – |
| Testing | – | – | – | – | – |
| Electrical power quality / power quality (active and passive filters)Engineering | – | – | – | – | – |
| Energy efficiency measurement according to ISO 50001Testing | – | – | – | – | – |
| Service, maintenance and inspection of UPS systems and reactive power compensationEngineering | – | – | – | – | – |
23 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Online UPS system 1-3kVA (Convert II 1000/2000/3000) | B & W / W_SVS Convert II 1000, 2000, 3000 | 3 | 1/1 phase, power factor 0.9, THD < 3% | – | St. Pölten |
| Online UPS system from 6kVA (Convert II 6000/10000) | B & W / W_SVS Convert II 6000, 10000 | – | 1/1 phase, power factor 1, THD < 6% | – | St. Pölten |
| Modular online UPS (Wisus-MC 30-120 N+1) | B & W / W_SVS Wisus-MC 30-120 N+1 | – | 3/3 phase, up to 120kW N+1, input voltage range 138-485 VAC | – | St. Pölten |
| Online UPS rack (WP-R 25-100kW) | B & W / W_SVS WP-R | – | 3/3 phase, up to 4 units of 10/20/25kW modules up to 100kW | – | St. Pölten |
| Online UPS tower (WP-T 10-60kW / 80-250kW) | B & W / W_SVS WP-T | – | 3/1 phase: 10, 20, 25kW; 3/3 phase: 10-60kW and 80-250kW | – | St. Pölten |
| Online UPS cabinet (WP-S 25-300kW) | B & W / W_SVS WP-S | – | 3/3 phase, up to 10 units of modules up to 300kW | – | St. Pölten |
| Modular online UPS (Wisus-ME / Wisus-MS 50-800kW) | B & W / W_SVS Wisus-ME, Wisus-MS | – | 3/3 phase, up to 16 units of 50kW modules, max. efficiency 96-97% | – | St. Pölten |
| Outdoor UPS (Atrox 350-2000 W) | B & W / W_SVS Atrox 350-2000 W | – | IP44, IK10 | – | St. Pölten |
| Outdoor UPS (FXM 350-2000 W) | B & W / W_SVS FXM 350-2000 | – | -40 to +74°C, power factor 1, 19" rack mounting | – | St. Pölten |
| Mobile measuring devices power quality (PQ-Box 300, 200, 150, 50) | A-Eberle PQ-Box 300 / 200 / 150 expert / 50 expert / 50 basic | – | Time and frequency domain, DC voltage up to 20 MHz | – | St. Pölten |
| Mains filters up to 630A | – | 3 | up to 630A | – | St. Pölten |
| Active / Passive / Hybrid harmonic filters | – | – | – | – | St. Pölten |
| Inverter output filters (sine filter, all-pole sine filter, dU/dt filter, motor choke) | 3AFS400, 3AFSAP400, 3AFU400, 3AFD480 | – | – | – | St. Pölten |
| Reactive power compensation floor cabinet (plug-in/modular technology, thyroswitch) | multicab-r | – | 75 to 400 kVAr, detuning factor 5.5/7/8/12.5/14%, 440 or 525 V | – | St. Pölten |
| Reactive power compensation wall cabinet / detuned fixed stage | multicab-r / multicab-f | – | 25-150 kVAr (wall cabinet), 5-60 kVAr (fixed stage) | – | St. Pölten |
| Compensation modules / mounting plates | multimod-R / multimod-F | – | 5 to 100 kVAr | – | St. Pölten |
| Reactive power controllers (multicomp D6 LCD Bus, multicomp 144-3ph) | multicomp D6 / F144 | – | Door mounting 96x96 or 144x144, 4-quadrant | – | St. Pölten |
| Energy meters EMU Professional II 3/5 and 3/100 (TCP IP, Modbus, M-Bus, LoRa) | EMU EMU Professional II | 20 | Direct connection up to 100A / transformer connection 3/5, MID approval | – | St. Pölten |
| KBR energy data management measuring devices (Multimess 1D-4, Multimess 4F144, Multisio) | KBR Multimess 4F144, Multimess 1D-4, Multisio | – | – | – | St. Pölten |
| Current transformers (through-type, retrofit, summation current transformers, multict) | multict KBU, CTM7, KBR | – | primary 32A to 5000 A, secondary 1A or 5A, class from 0.5 | – | St. Pölten |
| Switched-mode power supplies (E-, EP-, EV-, Z-, ZPNW series) | E series, EP series, EV series, Z series, ZPNW series | – | 1A to 20A, efficiency 87-93%, input AC 180-550 V / DC 254-780 V | – | St. Pölten |
| Universal coupling element UKE 21B | UKE 21b | – | Rated voltage 12 V DC to 230 V AC | – | St. Pölten |
| Batteries for UPS systems (First Power lead-fleece) | First Power | – | Service life up to +12 years | – | St. Pölten |
Additional services
Reference customers
Quality and Measurement Services
Measurement services are performed with wired connections in the low- and medium-voltage range in the time and frequency domain from DC voltage up to 20 MHz, in line with standards such as EN 50160, including interpretation of the measurement results and recommended actions. Energy efficiency measurements according to ISO 50001 complement the range of services.
| Evidence | St. Pölten |
|---|---|
| Measurements according to EN 50160 | |
| Energy efficiency measurement according to ISO 50001 | |
| MID approval energy meters |
History
- 1992
Company founded as a 2-man vision
- 2013
Start of energy data management with Visual Energy 4 at the chemical group Boehringer-Ingelheim (approx. 300 measuring points)