Engineering consultancy for building physics: thermal building physics, moisture protection, sound insulation and energy performance certificates since 1975

Bauphysik Feit GmbH
Klosterneuburg (AT) · Käferkreuzgasse 2-8/4/1, 3400 KlosterneuburgNew on Amplifa
About Bauphysik Feit
Bauphysik Feit GmbH is an engineering consultancy for building physics planning and consulting based in Klosterneuburg near Vienna. The service portfolio covers thermal building physics (thermal insulation, thermal bridge calculations, heat flow analyses, summer overheating protection), blower-door tests, energy performance certificates under EAVG/OIB and calculations of heating energy demand. A further focus is moisture protection with detailed design, condensation protection, water vapour diffusion calculations, moisture measurements and data logger evaluations. In the field of sound insulation, the consultancy offers building and room acoustics, including airborne and impact sound insulation verification, reverberation time assessment, structure-borne sound protection and room acoustic planning for event venues, cinemas and hotels. Building thermography is certified to DIN EN 473 (DIN 54162). Reference clients include Microsoft, ÖBB, the WKO Vienna, the Austria Center Vienna and the Federal Monuments Office; the consultancy has worked with architects such as David Chipperfield, Zaha Hadid, Coop Himmelb(l)au and Hans Hollein. The firm is run by Ing. Lukas Feit, the second generation of the family business.
- Site
- Klosterneuburg
- Processes
- Thermal building physics - thermal insulation / winter thermal protection, Blower-door tests, Preparation of energy performance certificates (EAVG) for all building categories according to OIB, Calculation of heating energy demand, Thermal bridge analysis / thermal bridge calculation / heat flow analyses / building thermography, Summer thermal protection / summer overheating, Calculation of heat storage capacity (effective thermal mass) of building components, Assessment of damage cases / renovation concepts / expert reports
- Materials
- Building thermography according to DIN EN 473 (DIN 54162), Blower-door test
- Certificates
- Building thermography certification DIN EN 473 (DIN 54162), DIN EN 473 (DIN 54162) building thermography
- Founded
- 1975
- Industries
- Architecture, Residential construction, Hotel/Catering, Event venues, Office/commercial buildings, Data centers
- 01
On-site consulting & assessment
- 02
Planning & model calculations
- 03
Measurement technology deployment (thermography, blower door, moisture,
- 04
Expert reports & verification
- 05
Project support through to completion
Services & Methods
Building thermography according to DIN EN 473 (DIN 54162)
Certified thermographic inspection of buildings for detecting thermal bridges and weak points.
Blower-door test
Measurement of the air tightness of buildings to assess winter thermal protection.
Locations

Klosterneuburg
ATOffice / headquarters
Inside the production


Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Thermal building physics - thermal insulation / winter thermal protectionEngineering | – | – | – | – | – |
| Blower-door testsTesting | – | – | – | – | – |
| Preparation of energy performance certificates (EAVG) for all building categories according to OIBEngineering | – | – | – | – | – |
| Calculation of heating energy demandEngineering | – | – | – | – | – |
| Thermal bridge analysis / thermal bridge calculation / heat flow analyses / building thermographyTesting | – | – | – | – | – |
| Summer thermal protection / summer overheatingEngineering | – | – | – | – | – |
| Calculation of heat storage capacity (effective thermal mass) of building componentsEngineering | – | – | – | – | – |
| Assessment of damage cases / renovation concepts / expert reportsTesting | – | – | – | – | – |
| Moisture protection detailed designEngineering | – | – | – | – | – |
| Condensation protection / water vapour diffusion calculationEngineering | – | – | – | – | – |
| Moisture measurements / data loggersTesting | – | – | – | – | – |
| Noise protection / building and room acoustics - planning & measurement of sound insulationTesting | – | – | – | – | – |
| Airborne and impact sound insulation - verification of sound insulation / structure-borne soundTesting | – | – | – | – | – |
| Room acoustics - room acoustic measurements / planning & design of common rooms,Engineering | – | – | – | – | – |
Additional services
Reference customers
Quality & Certification
Building thermography is certified to DIN EN 473 (DIN 54162); measurements are carried out with various measuring instruments including data loggers.
| Evidence | Klosterneuburg |
|---|---|
| DIN EN 473 (DIN 54162) building thermography |
History
- 1973
Start of consulting engineering activity in the context of the oil price shock
- 1975
Start of the office with the project engineering of the Korneuburg telephone exchange on behalf of the Post Directorate Vienna, Lower Austria and Burgenland
- 2026