Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search

Develops and manufactures monitoring devices for electrical safety: insulation, residual current and ground-fault resistance monitoring as well as power quality measurement technology.

BE

Bender GmbH & Co. KG

Grünberg (Hesse) · GermanyNew on Amplifa

1946Founded
approx. 1,350Employees
1 location (Grünberg)Headquarters
worldwideDelivery area

About Bender

Bender GmbH & Co. KG, headquartered in Grünberg (Hesse), develops and manufactures solutions that make electrical systems smarter and safer. The product portfolio includes insulation monitoring devices (ISOMETER®) for unearthed IT systems, residual current monitoring devices (LINETRAXX® RCMS/RCMA) for TN and TT systems, ground-fault resistance monitoring devices (NGR), power quality and energy meters (PEM, MID-certified energy meters), measuring and monitoring relays, current transformers, insulation fault location systems (ISOSCAN®), test equipment for electrical equipment (UNIMET®) as well as transfer and monitoring systems for medical locations (MEDICS®, ATICS®, isolating transformers). In addition, condition monitoring systems (COMTRAXX® CP907-I, POWERSCOUT®, edge500) are offered for predictive maintenance. The products are used, among other things, in mechanical and plant engineering, hospital technology, data centers, mining, railways, e-mobility, and the oil, gas and petrochemical industries. The family-owned company, founded in 1946, employs around 1,350 people and delivers worldwide.

Site
Grünberg
Processes
Insulation monitoring (ISOMETER®, Isolationswächter) for IT systems, Residual current monitoring (RCM/RCMS, LINETRAXX®) for TN/TT systems, Ground-fault resistance monitoring (NGR, NGRM series), Insulation fault location (ISOSCAN® EDS systems, portable locator devices), Testing of electrical equipment and medical-technical devices (UNIMET® safety testers), Calibration of safety testers (UNIMET®), Recurring testing of electrical installations according to DGUV Regulation 3 (BGV A3) with, System planning and electrical engineering design (industrial planner folder)
Materials
Insulation monitoring, Residual current monitoring (LINETRAXX®), Ground-fault resistance monitoring, Power quality and energy measurement, Insulation fault location (ISOSCAN®), Test equipment, Power supply for medical locations, Condition monitoring
Founded
1946
Employees
1350
Industries
Mechanical and plant engineering, Automotive industry, Hospital technology, Data centers, Mining, Railways
  1. 01

    Research and development

  2. 02

    System planning and electrical engineering design

  3. 03

    Manufacturing of monitoring and test devices

  4. 04

    Commissioning and installation (field service)

  5. 05

    Condition monitoring and maintenance

  6. 06

    Repair, calibration and retrofit

Products and Technologies

ISOMETER®

Insulation monitoring

Continuous monitoring of the insulation resistance of unearthed IT networks up to AC 1000 V/DC 1500 V, e.g. for medical IT systems, photovoltaics and drive/inverter applications.

RCM

Residual current monitoring (LINETRAXX®)

AC, pulsating and all-current sensitive monitoring of earthed TN and TT systems for fault and residual currents, also available as the SmartDetect series.

NGR

Ground-fault resistance monitoring

Monitoring of neutral grounding resistors in high-resistance and low-resistance earthed systems for limiting the fault current.

PEM

Power quality and energy measurement

Universal measuring devices and MID-certified energy meters for capturing currents, voltages, power, energy consumption and harmonics.

EDS

Insulation fault location (ISOSCAN®)

Systems and portable locator devices for pinpointing insulation faults in IT systems.

UNIMET®

Test equipment

Safety testers for testing electrical equipment and medical-technical devices, including calibration.

ATICS®/MEDICS®

Power supply for medical locations

Transfer and monitoring systems as well as isolating transformers for the power supply of medical rooms.

COMTRAXX®

Condition monitoring

Condition monitor with gateway (CP907-I), POWERSCOUT® and edge500 for condition-based maintenance and predictive maintenance.

CTUB

Current transformers

All-current sensitive measuring current transformers (type B) for residual current and load current measurement.

Locations

Grünberg

DE

Headquarters, development, manufacturing, support center

Industries

Mechanical and plant engineeringAutomotive industryHospital technologyData centersMiningRailwayse-mobilityOil, gas, petrochemicalsRenewable energiesPublic power supplyShips and portsMobile power generationFood and packaging machineryCrane and lifting technologyRobotics and welding technologyInduction heating/metals industryRenewable energies (wind, photovoltaics, CHP)Public power supply (power plants, substations)

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Engineering–––––
Insulation monitoring (ISOMETER®, Isolationswächter) for IT systemsTesting–––––
Residual current monitoring (RCM/RCMS, LINETRAXX®) for TN/TT systemsTesting–––––
Ground-fault resistance monitoring (NGR, NGRM series)Testing–––––
Testing–––––
Insulation fault location (ISOSCAN® EDS systems, portable locator devices)Testing–––––
Testing of electrical equipment and medical-technical devices (UNIMET® safety testers)Testing–––––
Calibration of safety testers (UNIMET®)Testing–––––
Recurring testing of electrical installations according to DGUV Regulation 3 (BGV A3) withTesting–––––
Testing–––––
Engineering–––––
Assembly–––––
Assembly–––––
System planning and electrical engineering design (industrial planner folder)Engineering–––––
Engineering–––––

Additional services

Telephone support/hotlineRepair service (repair, calibration, updates, replacement devices)Field service (commissioning, maintenance, troubleshooting)Maintenance/maintenance contractsSystem planningRemote servicesAnalysis of building installations (insulation fault location, power quality check, thermography)Seminars (Bender Academy)Consulting/application supportCondition monitoringRetrofit of existing systems

Reference customers

Pius Hospital OldenburgBrandenburg an der Havel University HospitalGlobal Mercy hospital shipDATEV eGTvilum (Denmark)Bachmann (cooperation, PDUs with Bender technology)

History

  1. 1946

    Founding of the company; active in the field of electrical safety for over 75 years.

  2. 2026

    80th company anniversary at the headquarters in Grünberg; Frank Baier takes over the newly created position of Chief Business Development Officer as of 1 August; Matthias Schwabe re-elected to the IFHE board.

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo