Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
BKE – Fertigung

Service provider for mobile measurement technology: temperature, pressure, flow, heat, electricity, indoor air and air hygiene measurements

BKE Logo

BK ENERGIE MESS AG

5113 Holderbank (Ausserfeld-Strasse 4) · 8952 Schlieren (Heimeliweg 7)New on Amplifa

AG (public limited company)Legal form
2Locations in Switzerland

About BK ENERGIE MESS AG

BK ENERGIE MESS AG (BKE), with locations in Holderbank and Schlieren (Switzerland), specialises in mobile measurement systems. The company performs measurements of temperature, pressure, humidity, flow (including clamp-on and non-contact), heat, power, gas and steam as well as electrical measurements and network analyses. Further focuses are thermography, the use of data loggers with data readout and data analysis, and as-is condition analyses as a basis for refurbishment proposals. In the area of heating check-ups, the company supports the dimensioning of pumps, boilers and hot water tanks as well as consumption-based heating cost billing. A dedicated offering covers the control and assessment of air hygiene in ventilation systems of apartments, offices and production rooms, including VOC and CO2 measurements, microbiological analyses, duct camera inspections and success checks. Target industries are building services (HVAC) as well as systems such as CHP units, heat pumps and solar/PV systems.

Site
Holderbank
Processes
Temperature measurement, Pressure measurement, Humidity measurement, Flow measurement / volume flow measurement (clamp-on, ultrasonic, clip-on, non-contact), Heat / power measurement, CO2 / VOC measurement, Microbiological analysis of air and surface samples, Thermography (infrared)
Materials
Temperature measurement, Pressure measurement, Humidity measurement, Flow / volume flow measurement, Heat / power measurement, Current measurement / network analysis, Gas / steam measurement, CO2 / VOC measurement
Industries
Building services / HVAC (heating, ventilation, air conditioning), Apartments, offices and production rooms, Plant engineering (CHP units, heat pumps, solar/PV systems)
  1. 01

    Requirements analysis / gathering of base data

  2. 02

    Mobile measurements with data loggers

  3. 03

    Data readout and data analysis

  4. 04

    As-is condition analysis / assessment

  5. 05

    Refurbishment proposal or recommendation of measures

  6. 06

    Success check

Measurement Methods

TEMP

Temperature measurement

Mobile acquisition of temperatures, e.g. at heating and plant systems.

DRUCK

Pressure measurement

Mobile pressure measurements on building services installations.

FEUCHTE

Humidity measurement

Measurement of relative and absolute humidity as well as indoor climate.

DF

Flow / volume flow measurement

Clip-on, non-contact measurement (clamp-on, ultrasonic) without intervention in the pipe.

WÄRME

Heat / power measurement

Heat and power measurements, including COP/efficiency measurement on heat pumps and CHP units.

STROM

Current measurement / network analysis

Electrical measurements and network analyses with voltage measurement.

GAS

Gas / steam measurement

Measurement of gases and vapours, e.g. at compressors and compressed air systems.

CO2/VOC

CO2 / VOC measurement

Air hygiene checks with sensor and logger recording usually over one week.

MIKRO

Microbiological analysis

Air and surface samples to detect microbial contamination.

THERMO

Thermography

Infrared thermal imaging inspection for the assessment of installations.

KAM

Duct camera inspection

Optical inspection of ducts and pipes with an own light source on screen.

LOG

Data loggers / data analysis

Recording, readout and graphical evaluation of measured data and operating states.

Locations

Holderbank

CH

Location

Materials
Mobile measurement technology

Schlieren

CH

Location

Materials
Mobile measurement technology

Inside the production

BK ENERGIE MESS AG
BK ENERGIE MESS AG

Industries

Building services / HVAC (heating, ventilation, air conditioning)Apartments, offices and production roomsPlant engineering (CHP units, heat pumps, solar/PV systems)

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Temperature measurementTesting–––––
Pressure measurementTesting–––––
Humidity measurementTesting–––––
Flow measurement / volume flow measurement (clamp-on, ultrasonic, clip-on, non-contact)Testing–––––
Heat / power measurementTesting–––––
CO2 / VOC measurementTesting–––––
Microbiological analysis of air and surface samplesTesting–––––
Thermography (infrared)Testing–––––
Current measurement / electrical measurement / network analysisTesting–––––
Gas / steam measurementTesting–––––
Climate measurement / indoor climateTesting–––––
COP / efficiency measurement (heat pumps, CHP units)Testing–––––
Optical inspection of ducts and pipes (duct camera)Testing–––––
Data recording / evaluation with data loggers, as-is condition analysesEngineering–––––
Heating check-up, pump / boiler dimensioning, refurbishment proposalsEngineering–––––

Additional services

Mobile measurement technology / mobile measurement systemsTemperature measurementPressure measurementHumidity measurementFlow / volume flow measurement (clamp-on, clip-on, non-contact)Heat and power measurementCO2, VOC and microbiological air quality measurementsThermography / thermal imagingNetwork analysis and current measurementData logger deployment, data readout and data analysisAs-is condition analyses and refurbishment proposalsHeating check-up, dimensioning (pumps, boilers, hot water tanks)Control and assessment of air hygiene in ventilation systems (incl. duct camera inspection)Success check after refurbishment measures
Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo