Development and manufacture of UV photometers, ozone measuring devices and ozone generators for industry and medicine
BMT MESSTECHNIK GmbH
Stahnsdorf (near Berlin)New on Amplifa
About BMT MESSTECHNIK
BMT MESSTECHNIK GmbH was founded in Berlin in 1975 and develops and manufactures ozone measuring instruments and generators. The product range includes UV photometers for ozone measurement in oxygen, air and ultrapure water (measuring ranges from 1 ppm to 600 g/Nm3), ozone monitors for ambient air, oncometers for measuring the colloid osmotic pressure of blood and plasma, as well as small, air-cooled and oxygen-fed ozone generators that reach concentrations above 250 g/Nm3. The portfolio is complemented by accessories such as sample gas dryers with Peltier cooling, filters, pumps, flow meters and ozone catalysts. Fields of application include, among others, the semiconductor industry, medical ozone therapy, industrial ozone applications and scientific research. Nearly twenty thousand ozone photometers have been produced by the company to date. In addition to development and production, the company offers support, repair service, software, spare parts and the disposal of legacy products at its site in Stahnsdorf near Berlin.
- Site
- Stahnsdorf
- Processes
- Development and manufacture of ozone measuring devices (UV photometers, ozone analyzers, ozone, Manufacture of ozone generators (small, air-cooled, oxygen-fed generators, up to >250, Ozone measurement in oxygen, air and ultrapure water (measuring ranges 1 ppm to 600 g/Nm3), Service and repair of own products (with Hazardous Material Certification), Development of measuring instruments for cardiac and circulatory research (oncometers, DC bridge, Support and repair service, Software, Manuals
- Materials
- UV photometers for ozone measurement, LED-based ozone photometer, Air-cooled ozone generators, Sample gas dryers, Oncometers
- Founded
- 1975
- Industries
- Semiconductor industry, Medical technology (medical ozone therapy), Industrial ozone applications, Scientific research
- 01
Development
- 02
Manufacture and testing of measuring instruments
- 03
Sales (direct and via partners)
- 04
Support, repair and disposal
Products & Technologies
UV photometers for ozone measurement
Measurement of ozone concentration in oxygen, air and ultrapure water in ranges from 1 ppm to 600 g/Nm3.
LED-based ozone photometer
In 1993, the BMT 590 was the first commercially available ozone photometer using visible LED light, developed for medical ozone therapy.
Air-cooled ozone generators
Small, oxygen-fed generators (BMT 802/803) for applications requiring a few grams of ozone per hour, with concentrations above 250 g/Nm3.
Sample gas dryers
Peltier-cooled sample gas dryers (from 1994, DH3) remove water vapour from the sample gas without affecting the ozone.
Oncometers
Membrane osmometers for measuring the colloid osmotic pressure of blood and plasma, used in intensive care medicine and open heart surgery.
Site

Stahnsdorf
DEHeadquarters: development, sales, delivery and service
- Materials
- Ozone measuring devices, ozone generators, accessories
Products



Inside the production

Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Development and manufacture of ozone measuring devices (UV photometers, ozone analyzers, ozoneEngineering | – | – | – | – | – |
| Manufacture of ozone generators (small, air-cooled, oxygen-fed generators, up to >250Engineering | – | – | – | – | – |
| Ozone measurement in oxygen, air and ultrapure water (measuring ranges 1 ppm to 600 g/Nm3)Testing | – | – | – | – | – |
| Service and repair of own products (with Hazardous Material Certification)Assembly | – | – | – | – | – |
| Development of measuring instruments for cardiac and circulatory research (oncometers, DC bridgeEngineering | – | – | – | – | – |
Additional services
Company History
- 1975
Founded as BMT MESSTECHNIK DR.-ING. FRANZ WALLNER in Berlin; development of electronic devices for cardiac and circulatory research
- 1979
Renamed BMT MESSTECHNIK GmbH
- 1981
Development of the ONKOMETER BMT 921, a worldwide patented membrane osmometer for the colloid osmotic pressure of blood/plasma
- 1984
Start of development of a UV photometer for ozone measurement in air or oxygen
- 1989
Market launch of the OZONE ANALYZER BMT 961
- 1990
Cabinet version of the BMT 961 for harsh environments
- 1992
Entry into small, air-cooled ozone generators
- 1993
Delivery begins of the OZONE ANALYZER BMT 590, the first commercially available ozone photometer with LED
- 1994
Development of the first Peltier-cooled sample gas dryer DH3
- 1995
Successors ONKOMETER BMT 923 and OZONE ANALYZER BMT 963
- 1996
OZONE-IN-WATER SENSOR BMT 963 AQ for ozone in ultrapure water (semiconductor industry)
- 1999
Sales launch of the OZONE MONITOR BMT 930 for ambient ozone
- 2002
OZONE ANALYZER BMT 964 with internal diagnostics and Windows software
- 2020
OZONE ANALYZER BMT 965 with lifetime logging and diagnostic functions