Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
Brandschutz Neubeck – Fertigung

Services in preventive fire protection: maintenance, inspection, training and planning in Schwerin

Brandschutz Neubeck Logo

Brandschutz Neubeck GmbH

Schwerin (Ziegeleiweg 3, 19057) · HeadquartersNew on Amplifa

GmbHLegal form (HRB 9234, Schwerin Local Court)
19057 SchwerinZiegeleiweg 3 location

About Brandschutz Neubeck

Brandschutz Neubeck GmbH is a specialist company for preventive fire protection based in Schwerin. Its service portfolio includes the maintenance and upkeep of smoke and heat extraction systems (RWA) in accordance with DIN 18232, the annual inspection of fire doors, smoke doors and door hold-open devices in accordance with DIN 14677, as well as planning, installation, acceptance and retrofitting of door hold-open devices. In addition, the company offers the provision and maintenance of certified fire extinguishers, service for smoke detectors and fire extinguishing water systems, the appointment of fire protection officers, practical training courses and instruction, and the preparation of escape and rescue plans, fire brigade plans, fire protection regulations and fire brigade route maps. Monitoring of maintenance intervals, a repair service and seamless documentation of all maintenance work complete the offering. The company is registered in the commercial register of the Schwerin Local Court (HRB 9234) and is managed by Ronald Zorn and Thomas Jonuscheit.

Site
Schwerin
Processes
Maintenance and upkeep of smoke and heat extraction systems (RWA), Inspection of smoke and heat extraction systems according to DIN 18232 (at least annually), Training on the function and operation of RWA systems, Maintenance and inspection of fire doors, smoke doors and door hold-open devices (annually, Planning, installation, acceptance, maintenance and retrofitting of door hold-open devices, Repair service for fire doors and door hold-open devices, Instruction on the correct handling of fire protection equipment, Appointment/consulting of fire protection officers
Materials
Smoke and heat extraction systems, Fire doors and door hold-open devices, Fire extinguishers, Smoke detectors, Fire extinguishing water systems
Certificates
Inspections according to DIN 18232, Maintenance according to DIN 14677, Seamless documentation
Industries
Preventive fire protection, Building management
  1. 01

    Consulting and planning (fire protection concept, plans)

  2. 02

    Installation and acceptance (including door hold-open devices)

  3. 03

    Maintenance and inspection according to DIN 18232 / DIN 14677

  4. 04

    Repair and retrofitting

  5. 05

    Documentation and monitoring of maintenance intervals

  6. 06

    Training and instruction of employees

Service Areas and Standards

RWA

Smoke and heat extraction systems

Maintenance, inspection and upkeep according to DIN 18232, at least once a year by a specialist company.

BST/FSA

Fire doors and door hold-open devices

Annual maintenance in accordance with DIN 14677, §53 ArbStättV, §17 MBO/LBO and DIBt guidelines.

FL

Fire extinguishers

Provision of certified fire extinguishers including maintenance.

RWM

Smoke detectors

Provision and service as a preventive fire protection measure.

LWA

Fire extinguishing water systems

Service and maintenance to ensure the fire extinguishing water supply in an emergency.

Locations

Standort Schwerin

Schwerin

DE

Headquarters

Services and Systems

Smoke and heat extraction system
Smoke and heat extraction systemMaintenance/Inspection · Preventive fire protection
Fire door
Fire doorMaintenance according to DIN 14677 · Building management
Door hold-open device
Door hold-open deviceInstallation, maintenance, retrofitting · Building management
Escape and rescue plan
Escape and rescue planPreparation · Building management

Inside the production

RWA service by Brandschutz Neubeck
RWA service by Brandschutz Neubeck
Fire protection concept
Fire protection concept
Fire safety assistant training
Fire safety assistant training
Evacuation assistant training
Evacuation assistant training
Company image of Brandschutz Neubeck
Company image of Brandschutz Neubeck

Industries

Preventive fire protectionBuilding management

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Maintenance and upkeep of smoke and heat extraction systems (RWA)Inspection–––––
Inspection of smoke and heat extraction systems according to DIN 18232 (at least annually)Inspection–––––
Training on the function and operation of RWA systemsEngineering–––––
Maintenance and inspection of fire doors, smoke doors and door hold-open devices (annuallyInspection–––––
Planning, installation, acceptance, maintenance and retrofitting of door hold-open devicesAssembly–––––
Repair service for fire doors and door hold-open devicesAssembly–––––
Instruction on the correct handling of fire protection equipmentEngineering–––––
Appointment/consulting of fire protection officersEngineering–––––
Training courses and instruction (fire protection)Engineering–––––
Preparation of escape and rescue plans, fire brigade plans, fire protection regulations andEngineering–––––
Maintenance and upkeep of protective equipmentInspection–––––
Smoke detectors (provision/service)Inspection–––––
Fire extinguishing water systems (service/maintenance)Inspection–––––
Fire extinguishers (certified fire extinguishers, maintenance)Inspection–––––

Additional services

Fire protection officerTraining courses and instructionEscape and rescue plans, fire brigade plans, fire protection regulations, fire brigade route mapsMaintenance and upkeepSmoke detectorsFire extinguishing water systemsSmoke and heat extraction systems (RWA)Fire doors and door hold-open devicesFire extinguishersInstallation, acceptance, retrofitting of door hold-open devicesMonitoring of maintenance intervals, controlling, documentationInspections according to DIN 18232, DIN 14677

Quality and Standards Compliance

Maintenance and inspections are carried out in compliance with standards by qualified experts in accordance with DIN 18232 (RWA) or DIN 14677, §53 ArbStättV, §17 MBO/LBO and DIBt guidelines (fire doors/door hold-open devices). All maintenance work is documented seamlessly and maintenance intervals are monitored.

EvidenceSchwerin
Inspections according to DIN 18232
Maintenance according to DIN 14677
Seamless documentation
Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo