Independent coating inspection, testing and consulting in industrial corrosion protection according to FROSIO Level III (NS 476).

Büro für Korrosionsschutztechnik, Dipl. Ing. Sven Svoboda
Kolpingstrasse 9, 50389 Wesseling (Office for Corrosion Protection Technology)New on Amplifa
About the Office for Corrosion Protection Technology
The Office for Corrosion Protection Technology of Dipl. Ing. Sven Svoboda in Wesseling provides services in coating inspection and quality assurance in industrial corrosion protection. The range of services covers inspections before, during and after coating application, dry film thickness measurement (DFT), adhesion testing to ASTM D4541 and D3359, salt contamination testing according to the Bresle method, as well as pinhole and holiday testing. In addition, non-destructive testing methods (VT, MT, PT, ET, UT), failure analyses, maintenance inspections as well as the development of coating specifications, project planning and quality assurance programmes are offered. The work is performed under FROSIO Level III certification according to the Norwegian standard NS 476 (certificate no. 9217). Clients include companies such as ABB, Steuler, Phönix Armaturen, Center Tech and Braskem, predominantly in Europe. The owner is a state-certified corrosion protection technician, graduate engineer and qualified planner for the maintenance of concrete structural components, and brings over 28 years of professional experience across more than 100 completed projects.
- Site
- Wesseling
- Processes
- Pre-coating surface inspection, During-application monitoring, Post-coating quality assessment, Maintenance inspections, Coating thickness measurement / Dry Film Thickness (DFT) measurement - magnetic and eddy current, Adhesion testing - Pull-off (ASTM D4541) and Cross-cut (ASTM D3359), Salt contamination assessment - Bresle method testing, Holiday detection (pinhole testing)
- Materials
- Visual Testing, Magnetic Testing, Penetrant Testing, Eddy Current Testing, Ultrasonic Testing, Dry Film Thickness Measurement, Steel and metallic materials
- Certificates
- FROSIO Inspector Level III (Norwegian Standard NS 476), FROSIO Inspector Level III (NS 476, Cert. No. 9217)
- Industries
- Industrial plants, Marine and offshore structures, Infrastructure (bridges, steel structures), Renewable energies (offshore wind), Tank and vessel construction, Pipelines
- 01
Consulting and specification development
- 02
Project planning
- 03
Surface inspection before coating
- 04
Monitoring during application
- 05
Testing and quality assessment after coating
- 06
Reporting and documentation
- 07
Maintenance inspections
Testing methods and materials examined
Visual Testing
Inspection with the naked eye or magnifying glasses up to 20x magnification to detect surface defects.
Magnetic Testing
Detects pores, cracks and inclusions at or just below the surface of ferromagnetic materials such as steel.
Penetrant Testing
Reveals surface-breaking cracks on non-porous materials using dye or fluorescent penetrants.
Eddy Current Testing
For electrically conductive materials; detects near-surface cracks and is used for coating thickness measurement.
Ultrasonic Testing
Volumetric method for wall thickness measurement and depth location of material defects.
Dry Film Thickness Measurement
Magnetic and eddy current measurement with calibrated digital instruments for specification control.
Steel and metallic materials
The main inspection objects are steel structures and metal components in plants, steel buildings and marine structures.
Location
Wesseling
DEOffice for Corrosion Protection Technology; on-site assignments at the customer's premises
- Materials
- Steel, metallic materials, coated surfaces
- Calibrated DFT measuring instruments (magnetic, eddy current)
- Adhesion testing equipment (pull-off)
- Bresle test equipment
- Holiday testing equipment
- Magnifying glasses up to 20x magnification
- MT, PT, ET and UT testing equipment
Inspected objects and components


Inside the production




Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Pre-coating surface inspectionTesting | – | – | – | – | – |
| During-application monitoringTesting | – | – | – | – | – |
| Post-coating quality assessmentTesting | – | – | – | – | – |
| Maintenance inspectionsTesting | – | – | – | – | – |
| Coating thickness measurement / Dry Film Thickness (DFT) measurement - magnetic and eddy currentTesting | – | – | – | – | – |
| Adhesion testing - Pull-off (ASTM D4541) and Cross-cut (ASTM D3359)Testing | – | – | – | – | – |
| Salt contamination assessment - Bresle method testingTesting | – | – | – | – | – |
| Holiday detection (pinhole testing)Testing | – | – | – | – | – |
| Failure analysis - root cause analysis, microscopic examination, chemical analysisTesting | – | – | – | – | – |
| Specification development (for coatings)Engineering | – | – | – | – | – |
| Project planning (for coating projects)Engineering | – | – | – | – | – |
| Quality assurance programmesEngineering | – | – | – | – | – |
| Detailed inspection reports, photographic evidence, compliance documentationTesting | – | – | – | – | – |
| Visual inspection (VT, magnifying glasses up to 7-20x)Testing | – | – | – | – | Steel, Metals |
| Magnetic particle testing (MT, ferromagnetic materials)Testing | – | – | – | – | ferromagnetic materials (steel) |
| Liquid penetrant testing (PT)Testing | – | – | – | – | – |
| Eddy current testing (ET, also coating thickness measurement)Testing | – | – | – | – | electrically conductive materials |
| Ultrasonic testing (UT, wall thickness and volumetric testing)Testing | – | – | – | – | – |
| Radiographic testing (RT, mentioned as an NDT method)Testing | – | – | – | – | – |
Additional services
Reference customers
Qualifications and quality assurance
All inspections are carried out according to the standards of the FROSIO Level III certification (Norwegian standard NS 476, certificate no. 9217). The results are documented in detailed test reports with photographic documentation and technical recommendations.
| Evidence | Wesseling |
|---|---|
| FROSIO Inspector Level III (NS 476, Cert. No. 9217) |
Professional background
Over 28 years of professional experience in coating inspection; more than 100 projects completed for clients in Europe and internationally.