About Calame Métrologie SA

Calame Métrologie SA, based in Carouge near Geneva, is a calibration laboratory accredited according to ISO/IEC 17025 (SCS 0088) for the measurement quantity Length. The company specializes in the calibration, maintenance, conversion, and sale of linear measuring benches from manufacturers SIP, Trimos, Mahr, Sylvac, Cary, Helios, Zeiss, and Movotelit, as well as the calibration and lapping of granite plates and reference surfaces. Accredited services include the positioning accuracy of measuring machines from 1D to 4 m and machine tools up to 30 m using a laser interferometer, angular deviations up to 15 m, and flatness calibrations from 400x400 mm (Union-Jack method). Non-accredited calibrations with factory certificates are provided for distance sensors, profile projectors, XY stages, vision machines, coordinate measuring machines, and angular sensors. Further services include electronic or laser interferometer retrofit for SIP measuring benches, the integration of Heidenhain scales, proprietary measurement software, and the sale of used measuring benches with SCS certificates. Calibrations are performed in the Carouge laboratory or on-site at the customer's location; the certificates are internationally recognized via ILAC-MRA.

Site
Carouge
Processes
SCS accredited calibration of 1D measuring machine positioning accuracy up to 1 m using, SCS accredited calibration of 1D measuring machine positioning accuracy up to 1 m using end gauge, SCS accredited calibration of 1D measuring machine positioning accuracy up to 0.1 m using gauge ring, SCS accredited calibration of 1D measuring machine positioning accuracy up to 1 m using step gauge, SCS accredited calibration of machine tool positioning accuracy up to 30 m using, SCS accredited calibration of angular deviations up to 15 m using angular laser interferometer, SCS accredited calibration of granite plates and reference surfaces from 400x400mm with, Calibration of linear distance sensors with factory certificate (Heidenhain, TESA, Sylvac, Mahr,
Materials
Granite, Laser Interferometry, End Gauge / Step Gauge, Gauge Ring
Certificates
ISO/IEC 17025 (SCS Accreditation, Accreditation No. SCS 0088), ISO/IEC 17025 (SCS 0088)
Founded
1990 (MCM
Industries
Metrology/Calibration Labs, Machine Tools, Precision Manufacturing, Quality Control/Instrumentation Monitoring
  1. 01

    Needs analysis and product selection (Consulting)

  2. 02

    Calibration using laser interferometer, end gauge, gauge ring, or Union-Jack

  3. 03

    Conversion/Retrofit (Electronics, Laser Interferometer, Heidenhain Integration)

  4. 04

    Maintenance or partial/complete overhaul

  5. 05

    Lapping of granite plates and measuring probes

  6. 06

    Software integration and measurement data transfer

  7. 07

    Accredited SCS certificate or factory certificate

  8. 08

    Archiving of measurement results

Reference Surfaces and Measuring Instruments

GRANIT

Granite

Material for measuring plates and reference surfaces, which are calibrated and lapped to DIN876/00 (<2.5 µm).

LI

Laser Interferometry

Process for the accredited calibration of the positioning accuracy of measuring and machine tools up to 30 m.

STUFENENDMASS

End Gauge / Step Gauge

Standard for accredited 1D calibrations of measuring machines up to 1 m.

EICHRING

Gauge Ring

Standard for accredited positioning accuracy calibrations up to 0.1 m.

Location

Carouge (Geneva)

CH

Calibration Laboratory and Company Headquarters

Materials
Granite (Lapping <400 mm in-house)
  • Trimos LabConcept Nano (Measuring range 350 mm, repeatability 0.03 µm)
  • Keysight 5530 Laser Interferometer System (up to 30 m)
  • Used SIP Measuring Benches 305M, MUL-300, MUL-1000
  • Heidenhain MT101 Measuring Probe with Granite Plate
  • Movotelit Measuring Instrument
  • Proprietary Measurement Software (Lineal, Acquisys, LabView, Mahr Transfer)

Industries

Metrology/Calibration LabsMachine ToolsPrecision ManufacturingQuality Control/Instrumentation Monitoring

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
SCS accredited calibration of 1D measuring machine positioning accuracy up to 1 m usingTesting0.1 µm + 0.4·10-6·L1 m–––
SCS accredited calibration of 1D measuring machine positioning accuracy up to 1 m using end gaugeTesting0.35 µm + 1.6·10-6·L1 m–––
SCS accredited calibration of 1D measuring machine positioning accuracy up to 0.1 m using gauge ringTesting0.45 µm + 1.5·10-6·L0.1 m–––
SCS accredited calibration of 1D measuring machine positioning accuracy up to 1 m using step gaugeTesting1.4 µm + 1.4·10-6·L1 m–––
SCS accredited calibration of machine tool positioning accuracy up to 30 m usingTesting0.2 µm + 1.4·10-6·L30 m–––
SCS accredited calibration of angular deviations up to 15 m using angular laser interferometerTesting0.8 µm/m + 3·10-3·A + 0.15 µm/m·L15 m–––
SCS accredited calibration of granite plates and reference surfaces from 400x400mm withTesting1.3 µm + 0.5·10-6·Lfrom 400x400 mm––Granite
Calibration of linear distance sensors with factory certificate (Heidenhain, TESA, Sylvac, Mahr,Testing–––––
Calibration of profile projectors, XY stages, vision machines, coordinate measuring machines withTesting–––––
Calibration of angular measuring sensors with factory certificateTesting–––––
Calibration of machine straightness and reference barsTesting–––––
Calibration, maintenance, and conversion of linear measuring benches (SIP, Trimos, Mahr, Sylvac,Testing–4 m (Accreditation up to 4m length)–––
Lapping of granite plates to DIN876/00 tolerance (~<2.5µm), in Carouge (<400mm) or on-site (>400mm)Surface~<2.5 µm (DIN876/00)400 mm (in Carouge) / >400 mm on-site––Granite
Electronic conversion (Retrofit) for linear measuring benches SIP including accredited SCSEngineering±3 µm null zone––––
Laser interferometer conversion for SIP Measuring Benches (Keysight 5530)Engineering–––––
Lapping of measuring probes with parallelism < 0.1 µmSurface< 0.1 µm––––
Sale of used measuring benches (SIP 305M, SIP MUL-1000, SIP MUL-300, Heidenhain MT101) withAssembly–––––
Integration of Heidenhain products (scales and measuring probes) into new and old machinesEngineering–––––

9 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Linear Measuring Bench / Horizontal Length Measuring DeviceTrimos LabConcept Nano1Application range 350/600/1100 mm, absolute measurement range 350 mm, max. load 60-90 kg,–Carouge (Geneva), Switzerland
Laser Interferometer Calibration SystemKeysight Technologies 55301Positioning accuracy up to 30 m (Machine tool calibration), Laser 5519A/B–Carouge (Geneva), Switzerland
Linear Measuring Bench (used, with USB electronics)SIP 305M–––Carouge (Geneva), Switzerland
Linear Measuring Bench (used, with Laser Interferometer)SIP MUL-1000–––Carouge (Geneva), Switzerland
Linear Measuring Bench (used, with USB electronics)SIP MUL-300–––Carouge (Geneva), Switzerland
Linear Measuring Bench (used, with Heidenhain Scale and Display)SIP 305M–––Carouge (Geneva), Switzerland
Measuring Probe with Granite Plate (used, Heidenhain ND280 display)Heidenhain MT101–––Carouge (Geneva), Switzerland
Measuring Instrument for Precision Parts and Calibration WeightsMovotelit–––Carouge (Geneva), Switzerland
SIP Measuring Machine Models (Maintenance/Conversion/Calibration)SIP 302M, 305M, 1002M, 304M, MUL-250, MUL-300, MUL-1000, 300M, 550M, 750M, 1000M,–––Carouge (Geneva), Switzerland

Additional services

SCS accredited calibration (ISO/IEC 17025, ILAC-MRA) of linear measuring benches (SIP, Trimos,Calibration of machine tools up to 30 m using laser interferometer (on-site)Calibration of granite plates/reference surfaces (Union-Jack method, laser interferometer)Non-accredited calibration with factory certificate (distance sensors, profile projectors,Maintenance and complete/partial overhaul of linear measuring benchesElectronic conversion (Retrofit SIPSI/USB electronics) for SIP measuring benchesLaser interferometer conversion for SIP measuring benches (Keysight)Sale of measuring benches (New/Used), SIP accessories, and spare partsLapping of granite plates up to DIN876/00 (<2.5µm)Heidenhain scale/measuring probe integrationSales of Keysight 5530 Laser Interferometer and Trimos LabConcept NanoCalibration of measuring probes (Lapping, Parallelism < 0.1µm)Proprietary measurement software (Lineal, Acquisys, LabView drivers, Mahr Transfer)Consulting: Needs analysis, product selection, measurement uncertainty calculation

Reference customers

Précision SA (Example customer in SCS certificate)

Accreditation and Quality

The SCS 0088 accreditation according to ISO/IEC 17025:2017 (valid 06.11.2023–05.11.2028, first accredited on 12.08.1998) ensures traceable calibrations against national standards; the certificates are internationally recognized via ILAC-MRA and are issued in German, French, or English. Measurement results are archived for 10 years.

EvidenceCarouge (Geneva)
ISO/IEC 17025 (SCS 0088)

History

  1. 1990

    Founding of MCM Calame Métrologie by Michel Calame

  2. 1991

    Relocation to Rue de Veyrier 18, 1227 Carouge

  3. 1998

    First SCS Accreditation No. 0088 according to ISO 17025 (12.08.1998)

  4. 2010

    Founding of Calame Métrologie SA by Remo Kaempfer

  5. 2011

    Acquisition of the business from MCM Calame Métrologie; new director Remo Kämpfer

  6. 2012

    Specialization in accredited calibration and maintenance of horizontal measuring benches

  7. 2015

    SCS accreditation expansion for measuring benches up to 4 m length

  8. 2016

    Specialization in lapping and calibration of measuring plates

  9. 2017

    Introduction of electronic conversion for SIP 302M and 305M measuring benches

  10. 2018

    Introduction of electronic conversion for all SIP measuring benches

  11. 2020

    Conversion for Movotelit; SCS extensions for gauge rings, angular deviations, and reference surfaces

  12. 2023

    Current SCS 0088 accreditation valid 06.11.2023–05.11.2028

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo