Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
CE-LAB – Fertigung

Accredited test laboratory for EMC, high voltage, lightning protection, equipment safety and climatic testing in Ilmenau

CE-LAB Logo

CE-LAB GmbH

IlmenauNew on Amplifa

1999Founded
Isabel1 Location: Ilmenau

About CE-LAB GmbH

CE-LAB GmbH is an independent test laboratory for developers and manufacturers of electrical and electronic devices, based in Ilmenau, Thuringia. The core of its business activities is standards-compliant EMC testing and measurements for the evaluation of interference emission and immunity in accordance with current directives, standards and manufacturer specifications. In addition, the laboratory conducts equipment safety tests in accordance with the ProdSG (German Product Safety Act) and the Low Voltage Directive as well as high-voltage tests (alternating voltage up to 60 kV, direct voltage up to 45 kV, impulse voltage measurement up to 150 kV), lightning current and impulse voltage tests on lightning protection components and surge protective devices, as well as climatic tests and environmental simulations in accordance with DIN EN 60068. Further service areas are calibration including on-site calibration, CE conformity assessment, consulting, training, standards research as well as expert reports and failure analyses. The laboratory is accredited by DAkkS in accordance with DIN EN ISO/IEC 17025 and designated by the Kraftfahrt-Bundesamt (KBA) as a Technical Service of categories A, B and D for EMC testing of vehicle components (e1/E1). The equipment is designed for products in information and automotive technology, medical devices and industrial products; test specimens up to 10 m edge length and 1000 kg can be tested in the laboratory.

Site
Ilmenau
Processes
EMC tests and measurements (laboratory, partial and acceptance tests), Immunity to electrostatic discharge (DIN EN 61000-4-2), Immunity to high-frequency electromagnetic fields (DIN EN IEC 61000-4-3) up to 6 GHz, Immunity to fast transient disturbances/burst (DIN EN 61000-4-4), Immunity to surge voltages (DIN EN 61000-4-5), Immunity to conducted disturbances (DIN EN 61000-4-6), Immunity to power-frequency magnetic fields (DIN EN 61000-4-8), Immunity to pulsed magnetic fields (DIN EN 61000-4-9)
Materials
Electromagnetic Compatibility (EMC Testing), Power and High-Voltage Engineering, Lightning and Surge Protection, Climatic Testing and Environmental Simulation, Equipment Safety, Calibration and Measuring Equipment Management, Automotive EMC (KBA Technical Service), CE Conformity Assessment and Consulting
Certificates
DIN EN ISO/IEC 17025 (DAkkS accreditation, EMC tests), KBA designated Technical Service (categories A, B, D), DIN EN ISO/IEC 17025 (DAkkS accreditation, D-PL-12133-01-00), KBA Technical Service (KBA-P 00079-06, Cat. A, B, D), EN ISO/IEC 17020 (basis of the KBA designation)
Founded
1999
Industries
Measurement, Control and Instrumentation Technology, Laboratory Technology, Automotive Engineering (Vehicles/Automotive), Information Technology, Household Appliance Technology, Renewable Energies / Photovoltaics
  1. 01

    Inquiry and test request

  2. 02

    Standards research and device assignment

  3. 03

    Test planning

  4. 04

    EMC tests and laboratory/on-site measurements

  5. 05

    High-voltage, lightning protection and climatic tests

  6. 06

    Evaluation and test reports/expert opinions

  7. 07

    Calibration and measuring equipment monitoring

Test and Measurement Methods

EMV

Electromagnetic Compatibility (EMC Testing)

Laboratory and on-site tests for interference emission and immunity in accordance with basic and product standards such as DIN EN 61000-4-x.

HS

Power and High-Voltage Engineering

Alternating voltage tests up to 60 kV/60 kVA and direct voltage tests up to 45 kV/6 kVA on in-house high-voltage test systems, impulse voltage measurement up to 150 kV.

BLITZ

Lightning and Surge Protection

Lightning current tests and impulse voltage investigations on lightning protection components and surge protective devices in accordance with EN 62305, EN 62561, EN 61643 and EN 61400.

KLIMA

Climatic Testing and Environmental Simulation

Heat-cold tests from -40 °C to 180 °C, humidity 10–98 % RH, temperature cycling and vibration in accordance with DIN EN 60068 in the climatic chamber with 335 l usable volume.

GS

Equipment Safety

Conformity tests in accordance with the Product Safety Act and the Low Voltage Directive 2014/35/EU, including dielectric strength, IP protection rating and leakage currents.

KAL

Calibration and Measuring Equipment Management

Calibration including on-site calibration as well as measurement and test equipment monitoring, DKD calibrations via cooperation partners.

KFZ

Automotive EMC (KBA Technical Service)

EMC testing of vehicle components in accordance with European (e1) and international (E1) regulations within type approval procedures.

CE

CE Conformity Assessment and Consulting

Guidance and support with CE marking including standards research, training, damage assessments and international product approval.

Locations

Standort Ilmenau

Ilmenau

DE

Test center: EMC test laboratory, high-voltage engineering, climatic testing, equipment safety (main site)

Part weight / size
Test specimens up to 1000 kg, max. 10 m edge length
Lot size
Single-unit and batch testing
Materials
EMC, high voltage, lightning protection, climatic testing, equipment safety
  • High-voltage test system, alternating voltage up to 60 kV/60 kVA
  • High-voltage test system, direct voltage up to 45 kV/6 kVA
  • Climatic chamber 335 l, -40 °C to 180 °C, 10–98 % RH
  • EMC test stations for interference emission and immunity
  • Thermal imaging camera for thermographic analysis

Test Objects

EMC testing of a device
EMC testing of a deviceEMC testing · Electronics/Device Technology
Equipment safety test
Equipment safety testEquipment Safety · Low Voltage Directive
High-voltage test
High-voltage testHigh-Voltage Engineering · Power and High Voltage
Heat measurement with thermal imaging camera
Heat measurement with thermal imaging cameraClimatic Testing · Thermographic Analysis

Inside the production

Ilmenau test center
Ilmenau test center
EMC test laboratory, view
EMC test laboratory, view
Measurement and test technology
Measurement and test technology
Service and laboratory area
Service and laboratory area
Test equipment and laboratory equipment
Test equipment and laboratory equipment
Ilmenau test laboratory
Ilmenau test laboratory
CE-LAB GmbH team
CE-LAB GmbH team

Industries

Measurement, Control and Instrumentation TechnologyLaboratory TechnologyAutomotive Engineering (Vehicles/Automotive)Information TechnologyHousehold Appliance TechnologyRenewable Energies / PhotovoltaicsMedical TechnologyMechanical EngineeringPower and High-Voltage EngineeringLightning and Surge Protection

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
EMC tests and measurements (laboratory, partial and acceptance tests)Testing–10 m (max. test specimen) × 10 m × 10 m1000 kg––
Immunity to electrostatic discharge (DIN EN 61000-4-2)Testing–––––
Immunity to high-frequency electromagnetic fields (DIN EN IEC 61000-4-3) up to 6 GHzTesting–––––
Immunity to fast transient disturbances/burst (DIN EN 61000-4-4)Testing–––––
Immunity to surge voltages (DIN EN 61000-4-5)Testing–––––
Immunity to conducted disturbances (DIN EN 61000-4-6)Testing–––––
Immunity to power-frequency magnetic fields (DIN EN 61000-4-8)Testing–––––
Immunity to pulsed magnetic fields (DIN EN 61000-4-9)Testing–––––
Immunity to voltage dips, short interruptions and voltage variations,Testing–––––
Immunity to variations of the power frequency, single-phase up to 16 A (DIN EN 61000-4-28)Testing–––––
Immunity to voltage dips on DC power inputs up to 32 A (DIN EN 61000-4-29)Testing–––––
Immunity at supply current >16 A per conductor, up to 32 A (DIN EN 61000-4-34)Testing–––––
Measurement of conducted interference emission (DIN EN 55016-2-1)Testing–––––
Measurement of radiated interference emission (DIN EN 55016-2-3)Testing–––––
Alternating voltage tests on high-voltage test systems up to 60 kV/60 kVATesting–––––
Direct voltage tests on high-voltage test systems up to 45 kV/6 kVATesting–––––
Impulse voltage measurement up to 150 kV, traceably calibratedTesting–––––
Testing of voltage or dielectric strength; insulating material tests; durability ofTesting–––––
Evaluation of high-current applications (connections, contacts); long-term andTesting–––––
Lightning current tests and impulse voltage investigations on lightning protection components andTesting–––––
Determination of response voltages, residual voltages or protection level of surge protectiveTesting–––––
Climatic testing: heat-cold test -40 °C to 180 °C, temperature cyclingTesting–––––
Humidity testing, relative humidity 10 % to 98 %Testing–––––
Environmental simulation (humidity, condensation, atmosphere, shocks/vibration) in accordance withTesting–––––
Thermographic analysis of heat emission; evaluation with touch sensorsTesting–––––
Equipment safety: dielectric strength, clearances and creepage distances, IP protection rating,Testing–––––
Safety tests on photovoltaic modules and solar industry componentsTesting–––––
On-site tests (industrial installations, EMC and equipment safety)Testing–––––
Calibration incl. on-site calibration; DKD calibrations via cooperation partnersTesting–––––
Shielding attenuation measurementTesting–––––
EMCU measurements (BImSchV, BGV, device compatibility)Testing–––––
Development-accompanying measurements, evaluation of device and circuit concepts,Engineering–––––
Consulting, training, standards research, CE conformity assessment, expert reports and failureEngineering–––––
EMC testing of vehicle components in accordance with European (e1) and international (E1)Testing–––––

3 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
High-voltage test system (alternating voltage)––up to 60 kV / 60 kVA–Ilmenau
High-voltage test system (direct voltage)––up to 45 kV / 6 kVA–Ilmenau
Climatic chamber––335 l usable volume; -40 °C to 180 °C; 10–98 % RH; tests with full function possible–Ilmenau

Additional services

EMC laboratory tests and on-site EMC testsEquipment safety (CE marking, ProdSG, Low Voltage Directive)Power and high-voltage engineering (AC up to 60 kV, DC up to 45 kV)Lightning and surge protection (lightning current and impulse voltage tests)Climatic testing and environmental simulationCalibration (including on-site calibration, DKD via cooperation partners)CE conformity assessment and international product approvalConsulting, training, further educationExpert reports and failure analysesDevelopment-accompanying measurementsStandards researchMeasurement and test equipment monitoring / measuring equipment management

Quality and Accreditation

CE-LAB GmbH works according to the quality principles for testing and calibration laboratories in accordance with DIN EN ISO/IEC 17025; results are obtained reliably, reproducibly and with documentation. Internal monitoring includes equipment calibrations, test station validations, participation in interlaboratory comparisons as well as laboratory documents describing procedures.

EvidenceIlmenau
DIN EN ISO/IEC 17025 (DAkkS accreditation, D-PL-12133-01-00)
KBA Technical Service (KBA-P 00079-06, Cat. A, B, D)
EN ISO/IEC 17020 (basis of the KBA designation)

Company History

  1. 1990

    Founding of CE-SYS GmbH Ilmenau, from whose EMC laboratory division CE-LAB GmbH emerged

  2. 1996

    Start of organizing the Thuringia EMC working group within the VDE district association

  3. 1999

    Registration of CE-LAB GmbH in the Jena commercial register as an independent company

  4. 2004

    Move into the new test center in Ilmenau; Dr. Michael Naß appointed managing director

  5. 2005

    Accreditation by DAkkS

  6. 2006

    First designation as Technical Service by the KBA on 24.03.2006; active since 2006 in the VDE committee for lightning protection and lightning research (ABB)

  7. 2009

    Founding member of ELMUG eG; head of the EMC & Equipment Safety expert group

  8. 2017

    Reaccreditation by DAkkS

  9. 2022

    Renewed KBA designation, valid from 25.04.2022 to 24.04.2027

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo