Manufacturer of sound level meters, noise dosimeters, vibration and environmental monitors with UKAS-accredited acoustic calibration.

Cirrus Research plc
Hunmanby (UK) · Frankfurt am Main · Lille · Beijing · Thomastown, Vic · Singapore · Birmingham, AlabamaNew on Amplifa
About Cirrus Research
Cirrus Research plc develops and manufactures acoustic measurement instruments for occupational, environmental and industrial noise as well as for vibration and air quality monitoring. The product range includes Class 1 sound level meters (Optimus/Optimus+ to IEC 61672-1), wireless noise dosimeters (doseBadge, including the intrinsically safe variant CR:110AIS with ATEX/IECEx/FM/CSA approval), cloud-based long-term noise monitors (Quantum Outdoor/Indoor), nuisance noise recorders (Trojan2/TrojanLITE), noise-activated warning signs, vehicle noise monitors and, in cooperation with South Coast Science, MCERTS-certified air quality monitors (PM1/PM2.5/PM10). At its headquarters in North Yorkshire, the company operates a UKAS-accredited acoustic calibration laboratory (No. 10148, ISO/IEC 17025), which also verifies instruments from other manufacturers against traceable standards. A global network of sales and service locations in Germany, France, China, Australia, Singapore and the USA offers calibration, maintenance, training and leasing. Customers come from industries such as aviation, construction, transport, mining, oil and gas, and occupational safety.
- Site
- Frankfurt am Main
- Processes
- Sound level measurement (sound level meters for occupational, environmental and industrial noise), Noise dosimetry / personal noise exposure monitoring (doseBadge), Vibration measurement (hand-arm and whole-body vibration), Long-term environmental noise monitoring (unattended noise monitors, cloud-based, Quantum, Nuisance noise recorders (Trojan2, TrojanLITE), Vehicle noise measurement / roadside monitoring, Air quality and particulate matter monitoring (PM1, PM2.5, PM10, gaseous pollutants,, Noise-activated warning signs
- Materials
- Sound level measurement (Class 1), Noise dosimetry, UKAS-accredited calibration, Intrinsic safety manufacturing, Air quality monitoring
- Certificates
- ISO 9001:2015, ISO 14001 (environmental management), UKAS accreditation calibration laboratory ISO/IEC 17025, BS EN ISO/IEC 80079-34 (intrinsic safety, doseBadge CR:110AIS), ISO 14001, UKAS / ISO/IEC 17025 (calibration laboratory No. 10148), BS EN ISO/IEC 80079-34 (intrinsic safety), ATEX/IECEx/FM/CSA (CR:110AIS doseBadge)
- Founded
- 1970
- Industries
- Aviation & Airports, Construction, Transport & Traffic, Mining & Quarrying, Oil & Gas, Environmental Monitoring
- 01
Development and manufacture of measurement instruments
- 02
Approval and certification (including intrinsic safety)
- 03
UKAS-accredited or traceable calibration
- 04
Service, repair and firmware updates
- 05
Cloud-based data monitoring (Quantum, doseBadge Portal)
- 06
Training and certification of users
Technologies & Processes
Sound level measurement (Class 1)
Measurement of occupational, environmental and industrial noise with the Optimus/Optimus+ series.
Noise dosimetry
Personal noise exposure monitoring with the wireless doseBadge, intrinsically safe in the CR:110AIS variant.
UKAS-accredited calibration
Verification of sound level meters, acoustic calibrators and octave band filters from any manufacturer.
Intrinsic safety manufacturing
Quality system for the manufacture of the intrinsically safe CR:110AIS dosimeter (ATEX/IECEx/FM/CSA).
Air quality monitoring
Praxis Urban/OPCube monitors measure PM1, PM2.5 and PM10 as well as gaseous pollutants.
Locations & Service Network

Hunmanby
GBHeadquarters, production and UKAS calibration laboratory (No. 10148)
- UKAS-accredited acoustic calibration laboratory (ISO/IEC 17025)
- Manufacture of sound level meters and dosimeters
Frankfurt am Main
DESales and service location (Cirrus Research GmbH, calibration centre)
- Service location / calibration centre
Lille
FRSales (Cirrus Research France)
Beijing
CNSales (Cirrus Research China)
Thomastown, Vic
AUService centre (partner: Active Environmental Solutions)
Singapore
SGService centre (partner: Ensscom Pte. Ltd.)
Birmingham, Alabama
USService centre (partner: OHD, LLLP)
Measurement Instruments









Inside the production




Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Sound level measurement (sound level meters for occupational, environmental and industrial noise)Testing | – | – | – | – | – |
| Noise dosimetry / personal noise exposure monitoring (doseBadge)Testing | – | – | – | – | – |
| Vibration measurement (hand-arm and whole-body vibration)Testing | – | – | – | – | – |
| Long-term environmental noise monitoring (unattended noise monitors, cloud-based, QuantumTesting | – | – | – | – | – |
| Nuisance noise recorders (Trojan2, TrojanLITE)Testing | – | – | – | – | – |
| Vehicle noise measurement / roadside monitoringTesting | – | – | – | – | – |
| Air quality and particulate matter monitoring (PM1, PM2.5, PM10, gaseous pollutants,Testing | – | – | – | – | – |
| Noise-activated warning signsTesting | – | – | – | – | – |
| UKAS-accredited acoustic calibration (ISO/IEC 17025) for sound level meters, acousticTesting | – | – | – | – | – |
| Traceable acoustic and vibration calibration, service, repair,Testing | – | – | – | – | – |
| Manufacture of noise measurement instruments (intrinsically safe version CR:110AIS doseBadge,Engineering | – | – | – | – | – |
8 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Sound level meters (Optimus / Optimus+ series, Class 1 to IEC 61672-1) | Cirrus Research Optimus / Optimus+ | – | – | – | – |
| Noise dosimeters (doseBadge, wireless, intrinsically safe variant CR:110AIS) | Cirrus Research doseBadge / CR:110AIS | – | – | – | – |
| Class 1 noise monitor to IEC 61672-1 (cloud-based, environmental monitoring) | Cirrus Research Quantum Outdoor | – | – | – | – |
| Class 2 noise monitor to IEC 61672-1:2013 (cloud-based, indoor) | Cirrus Research Quantum Indoor | – | – | – | – |
| Nuisance noise recorder with Class 1 sound level meter IEC 61672:2013 | Cirrus Research Trojan2 / TrojanLITE | – | – | – | – |
| Air quality monitor (PM1/PM2.5/PM10, MCERTS-certified) | South Coast Science Praxis Urban / Praxis OPCube | – | – | – | – |
| UKAS-accredited acoustic calibration laboratory (laboratory No. 10148, ISO/IEC 17025) | Cirrus Research | 1 | – | – | North Yorkshire, UK |
| Service location / calibration centre | Cirrus Research GmbH | 1 | – | – | Frankfurt am Main, Germany (Rennbahnstraße 72-74) |
Additional services
Reference customers
Quality & Accreditations
Cirrus Research is certified to ISO 9001:2015 and ISO 14001 by BSI and operates a UKAS-accredited calibration laboratory (ISO/IEC 17025, No. 10148); the quality systems for intrinsic safety manufacturing are verified to BS EN ISO/IEC 80079-34 by SGS Baseefa.
| Evidence | Hunmanby | Frankfurt am Main |
|---|---|---|
| ISO 9001:2015 | ||
| ISO 14001 | ||
| UKAS / ISO/IEC 17025 (calibration laboratory No. 10148) | ||
| BS EN ISO/IEC 80079-34 (intrinsic safety) | ||
| ATEX/IECEx/FM/CSA (CR:110AIS doseBadge) |
History
- 1970
Company founded; over 50 years of calibration and manufacture of noise and vibration measurement technology
- ca. 1995
Introduction of the wireless doseBadge noise dosimeter
- 2014
Intrinsic safety certifications (ATEX, IECEx, FM/CSA) for the CR:110AIS doseBadge; verification of the quality systems to BS EN ISO/IEC 80079-34 by SGS Baseefa; ISO 9001/14001 updated.
- 2018
UKAS accreditation as one of only five accredited acoustic calibration laboratories in Great Britain.
- 2022
Introduction of the cloud-based environmental monitor Quantum Outdoor.
- 2023
Accudata Ltd becomes official rental partner.
- 2025
Active Environmental Solutions (Australia) becomes a certified service centre; Net4Cities cooperation for urban noise abatement.
- 2026
New version of the NoiseTools software; new doseBadge compliant with IEC 61252:2025.