Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
CS-Chromatographie – Fertigung

Manufacturer of separation columns and accessories for chromatography as well as services for chemical analysis technology.

CS-Chromatographie Logo

CS-Chromatographie Service GmbH

LangerweheNew on Amplifa

1985Founded
LangerweheSite with production, laboratory, warehouse and shipping

About CS-Chromatographie

Since 1985, CS-Chromatographie Service GmbH has been developing and producing chromatography products at its Langerwehe site. The product range includes separation columns for high-performance liquid chromatography (HPLC), FS columns for capillary gas chromatography (GC), columns for capillary electrophoresis (CE), packed GC separation columns, coated support materials, derivatization reagents as well as empty and guard columns with fittings and connecting parts. In addition, liners for GC including a regeneration service (cleaning, deactivation, conditioning) are manufactured. As services, the company offers surface treatment of glass (silanization, siliconization, HCl treatment) and cleaning of PU foam filters according to VDI method BGI 505.47. For gas sampling, CS produces PU foam filters in numerous sizes as well as Florisil glass tubes and SPE cartridges. Customers come from chemical analysis technology, laboratory analytics, pharmacy as well as environmental and pesticide analytics. Custom-made columns and tubes are possible according to customer requirements.

Site
Langerwehe
Processes
Manufacture of separation columns for HPLC, Manufacture of FS columns for capillary gas chromatography (GC), Manufacture of separation columns for capillary electrophoresis (CE), Manufacture of packed GC separation columns, Manufacture of coated support materials for GC, Liner regeneration (cleaning, deactivation, conditioning), Sil deactivation (silanization) of glass surfaces, PM-Sil deactivation (phenyl-methyl silanization, medium-polar)
Materials
Glass, Polyurethane (PU foam GA 3035, standard density), Polyurethane (PU foam SH 100, low density), Florisil (magnesium silicate), Sodium sulfate, Silanized glass wool, Polyurethane foam (GA 3035, SH 100)
Certificates
ISO 9001:2015, AEO (Authorized Economic Operator), ISO 9001
Founded
1985
Industries
Chemical analysis technology, Laboratory analytics, Pharmacy, Environmental analytics, Pesticide analytics, Environmental analytics (pollutant/air monitoring)
  1. 01

    Development

  2. 02

    Manufacturing of columns and glass tubes

  3. 03

    Surface treatment/deactivation

  4. 04

    Quality control

  5. 05

    Warehouse and shipping

Materials and Processes

Glas

Glass

Base material for separation columns, liners, vials and sampling tubes; surfaces are deactivated by silanization, siliconization or HCl treatment.

PU

Polyurethane foam (GA 3035, SH 100)

PU foam filters in two densities for the enrichment of air pollutants during gas sampling.

Florisil

Florisil (magnesium silicate)

Adsorption material of highest purity in sampling tubes for PCB analytics and SPE cartridges according to the H53 method.

Na2SO4

Sodium sulfate

Filling material of the SPE cartridges for the H53 method.

Glaswolle

Silanized glass wool

Separation of the collection and breakthrough zone in sampling tubes as well as insert in GC liners.

Sites

Langerwehe

DE

Head office with production, laboratory, warehouse and shipping

Materials
Glass, polyurethane, Florisil

Components and Products

Separation columns for GC and HPLC
Separation columns for GC and HPLCIn-house production · Chromatography
Surface-treated glass and liners
Surface-treated glass and linersSilanization · Laboratory analytics
Florisil sampling tubes and cleaned PU foam filters
Florisil sampling tubes and cleaned PU foam filtersFilling/cleaning · Environmental analytics
PU foam filters (PUFs)
PU foam filters (PUFs)Production/cleaning · Air monitoring

Inside the production

Used, contaminated GC liners before regeneration
Used, contaminated GC liners before regeneration
Regenerated liners: cleaned and newly deactivated
Regenerated liners: cleaned and newly deactivated
Silanization of glass using the Sil, PM-Sil or INNO-Sil process
Silanization of glass using the Sil, PM-Sil or INNO-Sil process
Siliconization of glass surfaces
Siliconization of glass surfaces
HCl treatment of glass surfaces
HCl treatment of glass surfaces
Deactivated glass bottles and vials
Deactivated glass bottles and vials

Industries

Chemical analysis technologyLaboratory analyticsPharmacyEnvironmental analyticsPesticide analyticsEnvironmental analytics (pollutant/air monitoring)

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Manufacture of separation columns for HPLCEngineering––––Glas
Manufacture of FS columns for capillary gas chromatography (GC)Engineering––––Glas
Manufacture of separation columns for capillary electrophoresis (CE)Engineering––––Glas
Manufacture of packed GC separation columnsEngineering––––Glas
Manufacture of coated support materials for GCEngineering–––––
Liner regeneration (cleaning, deactivation, conditioning)Surface––––Glas
Sil deactivation (silanization) of glass surfacesSurface––––Glas
PM-Sil deactivation (phenyl-methyl silanization, medium-polar)Surface––––Glas
INNO-Sil deactivation (high-inert silanization)Surface––––Glas
Siliconization of glass surfacesSurface––––Glas
HCl treatment of glass surfaces (removal of metal ions and basic impurities)Surface––––Glas
Surface––––Polyurethane
Production of PU foam filters (PUFs) in numerous sizesPlastics––––Polyurethane
Engineering–approx. 100 mm × 10 mm OD x 8 mm ID––Glas, Florisil (magnesium silicate), silanized glass wool
Manufacture of Florisil cartridges/SPE cartridges for the H53 method (Na2SO4/Florisil, 15 mL)Engineering––––Glas, Florisil (magnesium silicate), Na2SO4

Additional services

Liner regeneration (cleaning, deactivation, conditioning)Surface treatment of glass (silanization, siliconization, HCl treatment)Cleaning of PU foam filters according to VDI method BGI 505.47Gas sampling / sampling tubesGC trainingCustom-made columns and tubes according to customer requirementsDistribution of catalogs and price lists (shop)

Quality and Certification

The quality management system is certified according to ISO 9001:2015 (TÜV Rheinland, certificate no. 74 210 0095); the Florisil sampling tubes have been tested for suitability by an accredited laboratory.

EvidenceLangerwehe
ISO 9001
AEO (Authorized Economic Operator)

History

  1. 1985

    Start of development and production of chromatography products

  2. 2017

    Initial certification according to ISO 9001 in June 2017

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo