Accredited laboratory for gas and hydrogen analysis, calibration of gas measuring instruments, and engineering for gas quality monitoring.

Dr. Ryll Lab GmbH
Berlin · Tulln (AT)New on Amplifa
About Dr. Ryll Lab
Dr. Ryll Lab GmbH was founded in Berlin in 2017 and is a manufacturer-independent service provider for gas analysis, sampling, calibration and maintenance of analytical measurement technology. In the accredited laboratory in Berlin, gas accompanying substances in hydrogen, natural and biogas, synthetic gases (SNG) and LNG are determined; hydrogen quality analysis is carried out in accordance with ISO 14687, SAE J2719 and DIN EN 17124. As a state-recognized testing body for gas measuring instruments, the company performs verification and calibration of gas quality and calorific value measuring instruments on site and certifies test and calibration gas mixtures. With a mobile testing laboratory, Dr. Ryll Lab measures hydrogen quality directly on site in real time; a mobile process gas chromatograph with Ex-Zone-1 approval is available for rent throughout Europe. The range of services is complemented by engineering and consulting for the design, planning and construction of gas quality monitoring systems as well as material compatibility tests using in-house developed test chambers. Through the 100% subsidiary H2Plas GmbH founded in 2021, production plants for hydrogen, carbon, synthesis gas and acetylene based on microwave plasma technology are being developed. Customers come from the gas and energy sector, from grid operators and municipal utilities, and from the hydrogen economy.
- Site
- Berlin
- Processes
- Hydrogen gas analysis (according to ISO 14687, SAE J2719, DIN EN 17124), Analysis of gas accompanying substances in natural and biogas, SNG, LNG, Material compatibility testing (emission of constituents such as sulfur compounds under, Gas sampling (sampling kit, on-site sampling), Verification and calibration of gas and calorific value measuring instruments and auxiliary devices, Certification of test and calibration gas mixtures, Maintenance, overhaul, repair and troubleshooting service for analytical measurement technology and, Leak testing of the entire measuring system
- Materials
- Hydrogen, Natural gas, Biogas, Synthetic gas (SNG), Liquefied natural gas (LNG), Ammonia, Biomethane, Biogas/Biomethane
- Certificates
- Accreditation DIN EN ISO/IEC 17025:2018 (flexible scope,, State-recognized testing body for gas measuring instruments, DIN EN ISO/IEC 17025:2018 (Accreditation D-PL-21354-01-00)
- Founded
- 2017
- Industries
- Gas industry / grid operators, Municipal utilities, Hydrogen economy / hydrogen mobility, Industrial gases, Energy industry (Power-to-Gas)
- 01
Sampling on site or via sampling kit
- 02
Laboratory analysis (gas chromatography, FID, dew point measurement)
- 03
Mobile measurement and validation (PGC, REKO/SmartSim)
- 04
Verification, calibration and certification of gases
- 05
Maintenance, overhaul and troubleshooting service
- 06
Engineering and construction of gas quality monitoring systems
Analyzed Gases and Media
Hydrogen
Quality analysis in accordance with ISO 14687, SAE J2719 and DIN EN 17124, especially for hydrogen mobility.
Natural gas
Determination of composition, water dew point and sulfur compounds according to recognized standards.
Biogas/Biomethane
Analysis of gas accompanying substances for feed-in providers and operators of biogas plants.
Synthetic gas (SNG)
Analytical investigation of synthetic gases for monitoring new gas types in the grid.
Liquefied natural gas (LNG)
Determination of gas accompanying substances in liquefied natural gas.
Ammonia
Feedstock for the production plants for hydrogen generation developed by H2Plas GmbH.
Locations
Berlin
DEHeadquarters, laboratory, state-recognized testing body
- Materials
- Hydrogen, natural gas, biogas, SNG, LNG
- Mobile process gas chromatograph (Ex-Zone 1)
- Mobile hydrogen quality testing laboratory
- In-house developed test chambers for material compatibility tests
- Measurement data recording system Marquis K-Gas
Tulln
ATSubsidiary Dr. Ryll Lab GmbH-Austria, business in Austria, Switzerland and Italy
Inside the production

Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Hydrogen gas analysis (according to ISO 14687, SAE J2719, DIN EN 17124)Testing | – | – | – | – | Hydrogen |
| Analysis of gas accompanying substances in natural and biogas, SNG, LNGTesting | – | – | – | – | Natural gas, Biogas, SNG, LNG |
| Material compatibility testing (emission of constituents such as sulfur compounds underTesting | – | – | – | – | – |
| Gas sampling (sampling kit, on-site sampling)Testing | – | – | – | – | – |
| Verification and calibration of gas and calorific value measuring instruments and auxiliary devicesTesting | – | – | – | – | – |
| Certification of test and calibration gas mixturesTesting | – | – | – | – | – |
| Maintenance, overhaul, repair and troubleshooting service for analytical measurement technology andTesting | – | – | – | – | – |
| Leak testing of the entire measuring systemTesting | – | – | – | – | – |
| Reference measurements dew point, sulfur etc.Testing | – | – | – | – | – |
| Mobile gas quality measurement with mobile PGC (Ex-Zone 1, validation REKO/SmartSim,Testing | – | – | – | – | – |
| Engineering and consulting: design, planning and construction of gas quality monitoring systems /Engineering | – | – | – | – | – |
| Planning and construction of analytical measurement technology and gas quality measurement systemsEngineering | – | – | – | – | – |
| Development of production plants for hydrogen, carbon, synthesis gas (E-Fuels) and acetyleneEngineering | – | – | – | – | Natural gas, Biomethane, Ammonia |
| Sampling of natural gas according to DIN EN ISO 10715 and DIN 51853Testing | – | – | – | – | – |
| Extended gas chromatography analysis of natural gas (DIN EN ISO 6975, DIN 51872-4)Testing | – | – | – | – | – |
| Determination of gaseous organically bound carbon with FID (DIN EN 12619, VDI 3481 Part 3)Testing | – | – | – | – | – |
| Determination of water dew point of natural gas with condensation hygrometer (DIN EN ISO 6327)Testing | – | – | – | – | – |
| Gas chromatographic determination of sulfur compounds (DIN 51855-8, ASTM D6228)Testing | – | – | – | – | – |
4 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Mobile process gas chromatograph (PGC) with Ex-Zone-1 approval | – | – | – | – | Berlin |
| Measurement data recording system | Marquis K-Gas | – | – | – | Berlin |
| In-house developed test chambers for material compatibility investigations | Dr. Ryll Lab | – | – | – | Berlin |
| Mobile hydrogen quality testing laboratory | Dr. Ryll Lab | – | – | – | Berlin |
Additional services
Quality & Accreditation
The laboratory is accredited in accordance with DIN EN ISO/IEC 17025:2018 (certificate D-PL-21354-01-00 dated 10.02.2023, flexible scope for natural gas and gas analysis test methods). In addition, the company has been a state-recognized testing body for gas measuring instruments since 2018.
| Evidence | Berlin | Tulln |
|---|---|---|
| DIN EN ISO/IEC 17025:2018 (Accreditation D-PL-21354-01-00) | ||
| State-recognized testing body for gas measuring instruments |
History
- 2017
Foundation of Dr. Ryll Lab GmbH in Berlin.
- 2018
Appointment as a state-recognized testing body for gas measuring instruments.
- 2020
Foundation of Dr. Ryll Lab GmbH-Austria in Tulln.
- 2021
Foundation of H2Plas GmbH, a 100% subsidiary for microwave plasma technology.
- 2023
Accreditation certificate D-PL-21354-01-00 according to DIN EN ISO/IEC 17025:2018 dated 10.02.2023.