Testing instruments and test systems for tablet hardness, dissolution and physical tests in pharmaceutical quality control
Dr. Schleuniger Pharmatron AG
Solothurn · Thun · Westborough (USA)New on Amplifa
About Dr. Schleuniger Pharmatron
Dr. Schleuniger Pharmatron AG develops, manufactures and distributes tablet testing instruments for production and quality control in the pharmaceutical industry. The focus is on complete tablet hardness test systems; in addition, the portfolio includes precision measurement of weight, thickness, width, diameter and breaking force (hardness/break force) of tablets as well as a PAT system for automated content uniformity testing with NIR for Real-Time Release (RTR). The range of physical testing instruments also comprises disintegration, friability (abrasion), bulk density, powder flow and cap torque test systems. Following the integration of the product line and services by the SOTAX Group in 2013, dissolution test systems (USP 1/2/5/6 manual, semi- and fully automatic as well as USP 4 flow-through), automated sample preparation (JetX™) and data management with q-doc® software are additionally offered. The Pharma Services team supports pharmaceutical companies worldwide with feasibility studies, method development, method automation, validation and method transfer. Locations are situated in Solothurn and Thun (Switzerland) as well as in Westborough, Massachusetts (USA).
- Site
- Solothurn
- Processes
- Tablet hardness testing (automatic, multi-parameter), Dissolution kinetics testing (Dissolution Testing USP 1/2/5/6, manual, semi- and fully automatic), Flow-through Dissolution Testing (USP 4), Sample preparation for content uniformity and assay testing (automated), Tablet disintegration testing, Friability testing (abrasion), Weight testing (tablets), Bulk density testing (tapped density)
- Materials
- Tablets (solid dosage forms), Capsules, APIs, Medical Implants, Microspheres, Nano-Suspensions, Semi-Solids, Transdermal Patches
- Founded
- 1972
- Industries
- Pharmaceutical Industry, Nutraceutical Industry
- 01
Development of testing instruments
- 02
Manufacturing and assembly of test systems
- 03
Worldwide distribution
- 04
Services & Support
- 05
Pharma Services (method development, validation, method transfer)
- 06
Data management with q-doc® software
Test tasks and sample materials
Tablets (solid dosage forms)
Testing of hardness, weight, thickness, diameter, disintegration, friability and content uniformity.
Capsules
Suitable for dissolution testing (USP 1/2/5/6 and USP 4).
APIs
Dissolution testing of poorly soluble active ingredients, in particular with flow-through cells (USP 4).
Medical Implants
Testing in the USP 4 flow-through dissolution system.
Microspheres
Dissolution testing of small sample volumes using the flow-through method.
Nano-Suspensions
Dissolution testing in the USP 4 flow-through system.
Semi-Solids
Testing of semi-solid dosage forms in the flow-through dissolution system.
Transdermal Patches
Dissolution testing in the USP 4 flow-through system.
Powders
Bulk density and flowability testing.
Locations
Solothurn
CHLocation
Thun
CHHeadquarters
Westborough
USLocation
Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Tablet hardness testing (automatic, multi-parameter)Testing | – | – | – | – | Tablets |
| Dissolution kinetics testing (Dissolution Testing USP 1/2/5/6, manual, semi- and fully automatic)Testing | – | – | – | – | Tablets, Capsules, APIs, Medical Implants, Microspheres, Nano-Suspensions, Semi-Solids, Transdermal Patches |
| Flow-through Dissolution Testing (USP 4)Testing | – | – | – | – | Tablets, Capsules, APIs, Medical Implants, Microspheres, Nano-Suspensions, Semi-Solids, Transdermal Patches |
| Sample preparation for content uniformity and assay testing (automated)Testing | – | – | – | – | Tablets |
| Tablet disintegration testingTesting | – | – | – | – | Tablets |
| Friability testing (abrasion)Testing | – | – | – | – | Tablets |
| Weight testing (tablets)Testing | – | – | – | – | Tablets |
| Bulk density testing (tapped density)Testing | – | – | – | – | Powders |
| Flowability testing (powder flow)Testing | – | – | – | – | Powders |
| Cap Torque Testing (closure torque testing)Testing | – | – | – | – | – |
| Content uniformity testing with NIR / PAT for Real-Time Release (RTR)Testing | – | – | – | – | Tablets |
| Engineering | – | – | – | – | – |
6 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Fully automatic dissolution test system | SOTAX ATF Xtend™ | – | – | – | – |
| Automatic tablet hardness tester | Dr. Schleuniger Pharmatron AT50 | – | – | – | – |
| Automated sample preparation system | SOTAX JetX™ | – | – | – | – |
| USP 4 flow-through cell dissolution tester | SOTAX CE 7smart | – | – | – | – |
| Tablet hardness tester | Dr. Schleuniger Pharmatron 5Y HV40RT | – | – | – | – |
| Tablet hardness tester (break force tester) | Dr. Schleuniger Pharmatron 6D | – | – | – | – |
Additional services
History
- 1972
Founded; specialized in tablet testing solutions since 1972
- 2013