Develops, manufactures and calibrates EMC test equipment and impulse generators for industry, energy, avionics, defense and telecom.

EMC PARTNER AG
Laufen (Baselstrasse 160, 4242 Laufen), Switzerland · Headquarters with production, development, calibration laboratory and serviceNew on Amplifa
About EMC PARTNER AG
EMC PARTNER AG was founded in 1994 by Martin Lutz in Laufen, northwestern Switzerland, and specializes in high-voltage impulse technology. The company develops, manufactures, tests and calibrates EMC test systems entirely in Switzerland, including ESD generators up to 30 kV, multifunctional impulse generators (EFT/Burst, Surge, Ringwave), combination wave generators up to 18 kV/9 kA, systems for indirect lightning effects per RTCA DO-160 as well as test equipment for MIL-STD-461, telecom standards (ITU-T K20/K21/K44) and energy technology. The products are used in industrial manufacturing, consumer and household electronics, avionics, defense, telecommunications as well as for smart meters, protection devices, charging infrastructure and solar inverters. At the headquarters in Laufen, production and development are complemented by an accredited calibration laboratory (ISO/IEC 17025, SCS 0146) and service; a worldwide network of representatives in around 43 countries and service centers in the USA, UK, Germany, Switzerland, Taiwan, India and South Korea round out the offering.
- Site
- Laufen
- Processes
- Development and manufacture of EMC test equipment (impulse generators), ISO/IEC 17025 accredited calibration (SCS 0146) of EMC test systems, ESD testing per IEC 61000-4-2 up to 30 kV, Surge/combination wave testing per IEC 61000-4-5 up to 25 kV / 6 kA, EFT/Burst testing per IEC 61000-4-4 up to 8 kV, Indirect lightning testing (avionics) per RTCA DO-160 / MIL-STD-461 CS117, Testing per MIL-STD-461 (CS06/CS106/CS115/CS116/CS117), Damped oscillatory waves (DOW) per IEC 61000-4-18
- Materials
- ISO/IEC 17025 accredited calibration, High-voltage impulse technology, Calibration laboratory SCS 0146
- Certificates
- ISO/IEC 17025 (accreditation Swiss Calibration Service SCS 0146), ISO/IEC 17025 (SCS 0146)
- Founded
- 1994
- Industries
- Industrial and household electronics, Energy technology (smart meters, smart grid, EV charging infrastructure,, Telecommunications / data networks, Avionics (RTCA DO-160), Defense (MIL-STD-461, MIL-STD-1275), Automotive / electromobility
- 01
Development (in-house development in Switzerland)
- 02
Production
- 03
Testing and accredited calibration (ISO/IEC 17025)
- 04
Shipping
- 05
Service, repair, updates, training
Processes & Test Areas
ISO/IEC 17025 accredited calibration
Accredited calibration of all manufactured EMC devices with measurement uncertainty per parameter and traceability to national standards.
High-voltage impulse technology
Development of impulse generators for ESD, EFT/Burst, Surge, Ringwave, DOW, lightning and telecom impulses.
Calibration laboratory SCS 0146
Own accreditation of the Swiss Accreditation Service for calibration per IEC 61000-4-x and ITU-T K44.
Locations

Laufen
CHHeadquarters with production, development, calibration laboratory and service
- Materials
- EMC test systems, impulse generators, calibration laboratory
- ESDEX ESD generators (8/16/30 kV)
- IMU-MGE / IMU-MGS impulse generators
- MIG surge generators (MIG1206, MIG1809-1P)
- AVI-LV3 / AVI-LV5 lightning generators
- MIL-MG3 test system
- Calibration laboratory per ISO/IEC 17025
Test Systems & Products





Inside the production





Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Development and manufacture of EMC test equipment (impulse generators)Testing | – | – | – | – | – |
| ISO/IEC 17025 accredited calibration (SCS 0146) of EMC test systemsTesting | – | – | – | – | – |
| ESD testing per IEC 61000-4-2 up to 30 kVTesting | – | – | – | – | – |
| Surge/combination wave testing per IEC 61000-4-5 up to 25 kV / 6 kATesting | – | – | – | – | – |
| EFT/Burst testing per IEC 61000-4-4 up to 8 kVTesting | – | – | – | – | – |
| Indirect lightning testing (avionics) per RTCA DO-160 / MIL-STD-461 CS117Testing | – | – | – | – | – |
| Testing per MIL-STD-461 (CS06/CS106/CS115/CS116/CS117)Testing | – | – | – | – | – |
| Damped oscillatory waves (DOW) per IEC 61000-4-18Testing | – | – | – | – | – |
| Magnetic field testing per IEC 61000-4-8/-9/-10Testing | – | – | – | – | – |
| Insulation/impulse voltage tests (1.2/50 µs) up to 30 kVTesting | – | – | – | – | – |
| Telecom/data line testing per ITU-T K20/K21/K44 (Power Induction, Power Contact, LightningTesting | – | – | – | – | – |
| AC/DC dips, variations and interrupts per IEC 61000-4-11/-29Testing | – | – | – | – | – |
| Service, repair, upgrades, training and calibration on-site and at service centersEngineering | – | – | – | – | – |
18 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| ESD generator (8/16/30 kV) | EMC PARTNER AG ESDEX 8kV / ESDEX 16kV / ESDEX 30kV | – | – | – | Laufen, Switzerland |
| Multifunctional impulse generator (EFT/Burst, Surge, Ringwave, 10/700) up to 8 kV, 16 A CDN | EMC PARTNER AG IMU-MGE | – | – | – | Laufen, Switzerland |
| Compact impulse generator EFT/Burst & Surge up to 5 kV | EMC PARTNER AG IMU-MGS | – | – | – | Laufen, Switzerland |
| Combination wave generator 12 kV / 6 kA | EMC PARTNER AG MIG1206 | – | – | – | Laufen, Switzerland |
| Surge generator CWG 12 kV / 6 kA, 2 ohms with automatic 1-phase CDN | EMC PARTNER AG MIG1206-1P | – | – | – | Laufen, Switzerland |
| Surge generator CWG 12 kV / 6 kA, 2 ohms with automatic 3-phase CDN | EMC PARTNER AG MIG1206-3P | – | – | – | Laufen, Switzerland |
| Surge generator CWG 18 kV / 9 kA per IEC 61180-2 | EMC PARTNER AG MIG1809-1P | – | – | – | Laufen, Switzerland |
| Indirect lightning generator (Level 3) | EMC PARTNER AG AVI-LV3 | – | – | – | Laufen, Switzerland |
| Indirect lightning generator (Level 5, Pin Injection & Cable Bundle) | EMC PARTNER AG AVI-LV5 | – | – | – | Laufen, Switzerland |
| Modular impulse test system for MIL-STD-461 & DO-160 | EMC PARTNER AG MIL-MG3 | – | – | – | Laufen, Switzerland |
| Multiple stroke lightning impulse generator | EMC PARTNER AG MIG0600MS | – | – | – | Laufen, Switzerland |
| Impulse current generator 24 kA with 4 outputs (8/20 µs) | EMC PARTNER AG MIG0624TEL | – | – | – | Laufen, Switzerland |
| Power induction test generator 1500 V | EMC PARTNER AG MIG-ITU-K44 | – | – | – | Laufen, Switzerland |
| DOW generator (Damped Oscillatory Wave) with 3-phase CDN | EMC PARTNER AG DOW-CG1 | – | – | – | Laufen, Switzerland |
| Impulse voltage tester 8 kV, 500 ohms, 0.5 J | EMC PARTNER AG INS-0805 | – | – | – | Laufen, Switzerland |
| Impulse voltage generator 500 V - 30 kV | EMC PARTNER AG INS-1250 | – | – | – | Laufen, Switzerland |
| Insulation test system up to 18 kV (1.2/50 µs, 40 ohms) | EMC PARTNER AG MIG1803 | – | – | – | Laufen, Switzerland |
| Impulse generator 1.2/50 µs up to 12 kV with step function | EMC PARTNER AG MIG1203 STEP | – | – | – | Laufen, Switzerland |
Additional services
Quality & Accreditation
EMC PARTNER AG is accredited by the Swiss Accreditation Service per ISO/IEC 17025 (SCS 0146) and calibrates all manufactured devices with traceability to national standards. The accreditation covers all EMC devices and is internationally recognized via ILAC MRA.
| Evidence | Laufen |
|---|---|
| ISO/IEC 17025 (SCS 0146) |
History
- 1994
Foundation of EMC PARTNER AG by Martin Lutz in Laufen, northwestern Switzerland
- 2024
30th company anniversary ('30 Years of Excellence')