Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search

EMC filters, power quality solutions and CE certification for automated machinery and industrial plants

EN

Enerdoor Group

Settimo Milanese (MI), Italy · Bedano, Switzerland · Westbrook, ME, USA · Vác, HungaryNew on Amplifa

1992Founded
5Locations in Italy, Switzerland, USA, Hungary
up to 4000 kVAPower range of voltage stabilizers
up to 10 GHzDesign capacity Custom Solutions
5 yearsWarranty on filter product lines

About Enerdoor

Founded in 1992, the Enerdoor Group develops and produces power quality and electromagnetic compatibility (EMC) solutions for automated machinery and industrial plants. The product portfolio includes EMI/RFI filters (single-phase, three-phase, three-phase plus neutral, DC), active and passive harmonic filters, line reactors, motor protection devices (sine wave filters, dV/dt filters, snubbers, load reactors), power transformers and voltage stabilizers up to 4000 kVA. In addition, the group offers flat-rate CE certification and pre-compliance testing to IEC and EN standards both on-site and in the laboratory, supported by mobile EMC laboratories, an anechoic chamber and an R&D facility. Further services include power quality and motor analyses, harmonic and RF disturbance analyses, troubleshooting, vibration and acoustic testing, TCF documentation as well as ATEX and product safety consulting. The group comprises Finmotor and Finlab in Italy, Enerdoor in North America and Switzerland, and Eichhoff Elektro in Hungary. Customers come from automation, machine tool building, military, renewable energy, data centers, HVAC and process plants.

Site
Settimo Milanese (MI), Italy
Processes
CE Certifications and Pre-Compliance Testing, EMC Compliance Testing (EMC Directive 2014/30/EU, FCC Part 15), Power Quality Analysis, Motor Analysis, Troubleshooting (EMC and Power Quality), Harmonic Distortion Analysis, RF Disturbance Analysis, Manufacturing of EMI/RFI filters (single-phase, three-phase, three-phase+neutral, DC)
Materials
EMI/RFI filters (single-phase, three-phase, plus neutral, DC), Active and passive harmonic filters and line reactors, Motor protection devices (sine wave filters, dV/dt filters, snubbers, load, Power transformers (single-phase, three-phase, autotransformers), Voltage stabilizers (single-/three-phase)
Certificates
EMC Directive 2014/30/EU, FCC Part 15 (USA), CE certification to IEC/EN, ISO 9001
Founded
1992
Industries
Automation, Machine tools, Military, Renewable energy (solar/wind), Data centers & IT infrastructure, HVAC
  1. 01

    Consulting and risk/pre-compliance analysis

  2. 02

    EMC measurement on-site or in the laboratory (mobile labs, anechoic chamber)

  3. 03

    Disturbance analysis (RF, harmonics, power quality, motor)

  4. 04

    Development and selection of filter/protection solutions

  5. 05

    Manufacturing of EMI/RFI filters, harmonic filters, transformers and

  6. 06

    Technical CE reports, certificates and TCF documentation

  7. 07

    Training and support

Services and Solution Approaches

EMI/RFI

EMI/RFI filters (single-phase, three-phase, plus neutral, DC)

Reduce conducted and radiated interference to meet EMC and FCC requirements.

HF

Active and passive harmonic filters and line reactors

Compensate harmonics in industrial grids up to 690 Vac and 800 A.

MP

Motor protection devices (sine wave filters, dV/dt filters, snubbers, load

Protect motors against voltage spikes and dV/dt stress.

PT

Power transformers (single-phase, three-phase, autotransformers)

Up to 225 kVA and 10 kVac primary voltage for industrial applications.

VS

Voltage stabilizers (single-/three-phase)

Stabilize mains voltage up to 4000 kVA for sensitive plants.

Group Locations

Finmotor – Settimo Milanese (MI)

IT

Headquarters and production

Materials
EMI/RFI filters, harmonic filters, motor protection devices, transformers, voltage stabilizers
  • Anechoic chamber
  • R&D facility

Finlab – Settimo Milanese (MI)

IT

EMC laboratory and testing

  • Mobile EMC laboratories

Enerdoor SA – Bedano

CH

Switzerland office

Enerdoor, Inc. – Westbrook, ME

US

North America office

Eichhoff Elektro Kft – Vác

HU

Hungary office

Industries

AutomationMachine toolsMilitaryRenewable energy (solar/wind)Data centers & IT infrastructureHVACProcess plantsIndustryAutomationProcess plants

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
CE Certifications and Pre-Compliance TestingTesting–––––
EMC Compliance Testing (EMC Directive 2014/30/EU, FCC Part 15)Testing–––––
Power Quality AnalysisTesting–––––
Motor AnalysisTesting–––––
Troubleshooting (EMC and Power Quality)Testing–––––
Harmonic Distortion AnalysisTesting–––––
RF Disturbance AnalysisTesting–––––
Manufacturing of EMI/RFI filters (single-phase, three-phase, three-phase+neutral, DC)Engineering–––––
Manufacturing of harmonic filters (active/passive) and line reactorsEngineering–––––
Manufacturing of motor protection devices (sine wave filter, dV/dt filter, snubber, load reactor)Engineering–––––
Manufacturing of power transformers (single-phase, three-phase, autotransformers)Engineering–––––
Manufacturing of voltage stabilizers (single-phase/three-phase)Engineering–––––
ATEX Consulting / Risk Assessment Support / Product Safety ConsultingEngineering–––––
Technical training and seminars (EMC/CE)Engineering–––––

3 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Anechoic chamber (camera anecoica)–––––
Mobile EMC laboratories (fully equipped)–2 accordin––worldwide / on-site
R&D facility–––––

Additional services

CE certification and pre-compliance testing (IEC/EN)EMC testing on-site with mobile laboratoriesPower Quality AnalysisMotor AnalysisTroubleshootingHarmonic Distortion AnalysisVibration testingAcoustic testingNon-ionizing testingTechnical CE reports and certificatesTechnical training and seminarsProduct safety consultingRisk assessmentATEX consultingTCF documentation (Technical Construction File)Custom Solutions (design up to 10 GHz)

Quality and Standards Compliance

Enerdoor performs EMC conformity testing according to the EMC Directive 2014/30/EU and FCC Part 15 as well as safety and low-voltage directives, and issues technical CE reports and final certificates. Testing takes place in the laboratory, in the anechoic chamber or on-site with fully equipped mobile EMC laboratories.

EvidenceSettimo Milanese (MI)
EMC Directive 2014/30/EU
FCC Part 15 (USA)
CE certification to IEC/EN
ISO 9001

History

  1. 1992

    Foundation of the Enerdoor Group; specialization in EMC measurement, CE certification and power quality

  2. 1996

    The CE Directive becomes mandatory; Enerdoor supports machine and plant builders with CE conformity

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo