Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search

Engineering office for firedamp and explosion protection, certifications, risk analyses and EMC technology

EX

ExGuide Technology – Günter Kämper VDI

Castrop-Rauxel (headquarters) · Essen (colleague for ATEX work)New on Amplifa

1992Founded (engineering office Günter Kämper)
DIN ISO 9001 since 1996Quality management system
ATEX & IECEx national & internationalField of activity
Günter Kämper VDIOwner

About ExGuide Technology

ExGuide Technology – Günter Kämper VDI is an engineering office founded in 1992 and based in Castrop-Rauxel, acting as an independent expert in the field of firedamp and explosion protection. The company supports manufacturers and operators of electrical and mechanical equipment throughout the entire explosion protection process: from certification under Directive 2014/34/EU (ATEX) and within the IECEx scheme, through the configuration and equipping of plants and machines for potentially explosive areas, to the preparation of explosion protection documents under Directive 1999/92/EC and the German Industrial Safety Ordinance (BetrSichV). The core element is the ignition hazard assessment according to ISO 80079-36 ff. with a statement of conformity from an independent third-party expert. The range of services is complemented by EMC testing, electrical measurements, hazard analyses under the Machinery and Explosion Protection Directives, and active participation in national and international standards work. Since January 2020, colleague Geoffrey Stenzel (Essen) has taken over the major part of the explosion protection work. A quality management system under DIN ISO 9001 has been in place since 1996.

Site
Castrop-Rauxel
Processes
Certification of equipment (ATEX Directive 2014/34/EU, IECEx scheme, gas and dust Ex area), Configuration and equipping of electrical plants and machines for potentially explosive, Preparation of explosion protection documents under Directive 1999/92/EC and BetrSichV, Risk analyses / ignition hazard assessment according to ISO 80079-36 ff. with statement of, EMC testing, EMC technology and electrical measurements, Hazard analyses under the EC Machinery Directive and the EU Explosive Atmospheres Directive, Certification of electrical and mechanical equipment (Directive 2014/34/EU ATEX, IECEx scheme, gas, Configuration and equipping of plants and machines for potentially explosive areas
Materials
FKM (sealing material in the Ex conformity assessment of a flow meter, not the company's own, Directive 2014/34/EU (ATEX), IECEx Scheme, Ignition hazard assessment, Explosion protection document, EMC Testing & Electrical Engineering
Certificates
DIN ISO 9001 (QM system), DIN ISO 9001
Founded
1992
Industries
Mining (firedamp protection), Potentially explosive installations / operators, Manufacturers of Ex equipment (e.g. metrology), Industry / operators of potentially explosive installations
  1. 01

    Consulting / initial assessment

  2. 02

    Certification under ATEX / IECEx

  3. 03

    Ignition hazard assessment (ISO 80079-36 ff.)

  4. 04

    Statement of conformity

  5. 05

    Explosion protection documentation

  6. 06

    EMC testing / measurements

Standards & Assessment Areas

ATEX

Directive 2014/34/EU (ATEX)

Certification of electrical and mechanical equipment for the gas and dust Ex area in Europe.

IECEx

IECEx Scheme

International certification of Ex equipment under the IECEx scheme.

ISO 80079-36

Ignition hazard assessment

Risk analyses of mechanical explosion protection according to ISO 80079-36 ff. by independent experts.

RL 1999/92/EG

Explosion protection document

Preparation of explosion protection documents for operators according to the Directive and BetrSichV.

EMV

EMC Testing & Electrical Engineering

EMC technology, electrical measurements and power engineering equipment.

Locations

Castrop-Rauxel

DE

Headquarters / engineering office

Materials
ATEX, IECEx, EMC

Essen

DE

Colleague – ATEX work (Geoffrey Stenzel)

Materials
ATEX

Industries

Mining (firedamp protection)Potentially explosive installations / operatorsManufacturers of Ex equipment (e.g. metrology)Industry / operators of potentially explosive installations

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Certification of equipment (ATEX Directive 2014/34/EU, IECEx scheme, gas and dust Ex area)Testing–––––
Configuration and equipping of electrical plants and machines for potentially explosiveEngineering–––––
Preparation of explosion protection documents under Directive 1999/92/EC and BetrSichVEngineering–––––
Risk analyses / ignition hazard assessment according to ISO 80079-36 ff. with statement ofTesting–––––
EMC testing, EMC technology and electrical measurementsTesting–––––
Hazard analyses under the EC Machinery Directive and the EU Explosive Atmospheres DirectiveEngineering–––––

Additional services

Certification of electrical and mechanical equipment (Directive 2014/34/EU ATEX, IECEx scheme, gasConfiguration and equipping of plants and machines for potentially explosive areasPreparation of explosion protection documents (Directive 1999/92/EC, BetrSichV)Risk analyses / ignition hazard assessment according to ISO 80079-36 ff. by independent expertsStatements of conformity as safety assessments by an independent third-party expertHazard analyses (EC Machinery Directive, EU Explosive Atmospheres Directive)EMC testing, EMC technology and electrical measurementsStandards work (national and international)Ex-Forum (community, training, standards status, Ex-Kompaß download)

Reference customers

Heinrichs Messtechnik GmbH (statement of conformity for flow meters, 2020)

Quality Management

A quality management system under DIN ISO 9001 has been in place since 1996. Statements of conformity are issued as safety assessments by an independent third-party expert.

EvidenceCastrop-Rauxel
DIN ISO 9001

History

  1. 1992

    Foundation of the owner's own engineering office for firedamp and explosion protection, electrical engineering and EMC technology

  2. 1996

    Establishment of a quality management system under DIN ISO 9001

  3. 2011

    Compact seminars on explosion protection (e.g. compact seminar November 2011)

  4. 2020

    Geoffrey Stenzel takes over the major part of the explosion protection work; Günter Kämper continues to provide support

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo