Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
FAHO – Fertigung

Development, manufacture and engineering of smoke protection pressure systems (SÜLA/RDA) and components for fire protection and ventilation technology.

FAHO Logo

FAHO GmbH

Kaufungen (headquarters, production and administration)New on Amplifa

2010Foundation of FAHO GmbH
1946Origin as Heinz Horch GmbH (roofing business)
over 1,000Engineered and executed SÜLA systems (2018)
up to 56,000 m³/hAir flow rate of the overpressure fans
HRB 14793, Kassel District CourtCommercial register

About FAHO

FAHO GmbH, based in Kaufungen near Kassel, develops, manufactures, engineers and services products for fire protection, smoke protection and ventilation technology. The core product is the safety overpressure ventilation system (SÜLA/RDA), which keeps escape and rescue routes such as fire-protected stairwells, fire brigade elevators and rescue tunnels free of smoke in the event of fire. The product range includes in-house developed overpressure fans of the NG 500 to NG 1000 series with flow rates of up to 56,000 m³/h, pressure control valves, smoke extraction dampers, the ARÜ pressure relief element with calcium silicate block and intumescent graphite, control systems, emergency power supplies as well as pressure relief elements and thermally insulated louvre dampers. The fan housings are made of hot-dip galvanised sheet steel to EN ISO 1461, impellers made of cast aluminium. In addition to manufacturing and installation, FAHO offers planning support for building services (TGA) offices, hot smoke tests for system acceptance, commissioning, maintenance and seminars. The company operates nationwide and implements projects ranging from residential buildings to special structures such as high-rise buildings, energy bunkers and waste-to-energy plants.

Site
Kaufungen
Processes
Development and sales of smoke protection pressure systems (SÜLA/RDA) and fire protection, Planning of project-specific SÜLA, smoke extraction and fire protection equipment in ventilation, Hot smoke test for visualisation of the function of SÜLA and smoke extraction systems (3, Commissioning and acceptance of systems, Manufacture/installation of fire protection, smoke protection and ventilation systems incl. fans,, Planning of project-specific SÜLA/RDA solutions, Hot smoke test (commissioning/acceptance of SÜLA systems), Commissioning and acceptance
Materials
Hot-dip galvanised sheet steel, Cast aluminium, Calcium silicate block with intumescent graphite
Certificates
Hot smoke test for acceptance, Commissioning and acceptance, Maintenance service, ISO 9001
Founded
2010
Industries
Residential construction, Special structures (fire brigade elevators, rescue tunnels, high-rise buildings), Building services (TGA) planning offices and fire protection experts, Industrial buildings, Special structures (e.g. fire brigade elevators, rescue tunnels, high-rise, Building services (TGA) planning offices / fire protection experts
  1. 01

    Engineering and development

  2. 02

    Engineering in cooperation with building services (TGA) planning offices

  3. 03

    Manufacture of system components

  4. 04

    Sales and technical elaboration

  5. 05

    Installation and site supervision

  6. 06

    Hot smoke test, commissioning and acceptance

  7. 07

    Maintenance service

Materials & Processes

EN ISO 1461

Hot-dip galvanised sheet steel

Housings of the high-performance duct fans with stable, pressed flanges.

AlGuss

Cast aluminium

Impellers with hub and profiled blades, continuously adjustable while stationary.

CS-BG

Calcium silicate block with intumescent graphite

Closes the connector of the ARÜ pressure relief element in a fire-resistant manner in the event of fire.

Locations

Standort Kaufungen

Kaufungen

DE

Production and administration building, headquarters

Materials
Hot-dip galvanised sheet steel, cast aluminium
  • Overpressure fans NG 500 to NG 1000
  • Fire gas fan BGV 24.000_400
  • 3 high-performance fog machines for hot smoke test (max. 160 °C)

Components & Products

Pressure relief element ARÜ 90
Pressure relief element ARÜ 90Fire protection component · Residential construction and special structures
SÜLA system, Bremen waste-to-energy plant
SÜLA system, Bremen waste-to-energy plantSmoke protection pressure system · Special structures
Installation overview SÜLA system
Installation overview SÜLA systemSystem solution · Fire-protected stairwell
Thermally insulated louvre damper, system status triggered
Thermally insulated louvre damper, system status triggeredFire damper · Ventilation technology

Inside the production

Hot smoke test Lübeck, after 5 minutes
Hot smoke test Lübeck, after 5 minutes
Hot smoke test MuK Lübeck
Hot smoke test MuK Lübeck
Fire-protected stairwell with SÜLA
Fire-protected stairwell with SÜLA
Reference Energy Bunker Hamburg-Wilhelmsburg
Reference Energy Bunker Hamburg-Wilhelmsburg
Reference Trumpf, Ditzingen
Reference Trumpf, Ditzingen
Reference Watertower, Hamburg
Reference Watertower, Hamburg

Industries

Residential constructionSpecial structures (fire brigade elevators, rescue tunnels, high-rise buildings)Building services (TGA) planning offices and fire protection expertsIndustrial buildingsSpecial structures (e.g. fire brigade elevators, rescue tunnels, high-riseBuilding services (TGA) planning offices / fire protection experts

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Development and sales of smoke protection pressure systems (SÜLA/RDA) and fire protectionEngineering––––Hot-dip galvanised sheet steel, Cast aluminium, Calcium silicate, Intumescent graphite
Planning of project-specific SÜLA, smoke extraction and fire protection equipment in ventilationEngineering–––––
Hot smoke test for visualisation of the function of SÜLA and smoke extraction systems (3Testing–––––
Commissioning and acceptance of systemsTesting–––––
Manufacture/installation of fire protection, smoke protection and ventilation systems incl. fans,Installation––––Hot-dip galvanised sheet steel (EN ISO 1461), Cast aluminium

7 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
High-performance duct fan overpressure fan NG 500FAHO NG 500 (type 10.000-165 to 12.000-620)–Air flow rate 5,000–14,000 m³/h, external pressure 165–620 Pa––
High-performance duct fan overpressure fan NG 560FAHO NG 560–Air flow rate 14,000–22,000 m³/h, external pressure 300–800 Pa––
High-performance duct fan overpressure fan NG 630FAHO NG 630–Air flow rate 16,000–27,000 m³/h, external pressure 550–1020 Pa––
High-performance duct fan overpressure fan NG 710FAHO NG 710 (type 16.000-600)–Air flow rate 16,000 m³/h, external pressure 600 Pa, power 5.5 kW, weight 78 kg––
High-performance duct fan overpressure fan NG 1000FAHO NG 1000 (type 46.000-550, 56.000-560)–Air flow rate 46,000–56,000 m³/h, external pressure 550–560 Pa, power 15–18.5 kW, weight 237–291––
Fire gas fanFAHO BGV 24.000_400––––
3 high-performance fog machines (hot smoke test)–3Temperature max. 160°––

Additional services

Planning of project-specific SÜLA/RDA solutionsHot smoke test (commissioning/acceptance of SÜLA systems)Commissioning and acceptanceMaintenance serviceSite supervisionSeminars and SÜLA demonstrationsR&D for fire protection and ventilation products

Reference customers

SWB waste-to-energy plant BremenWatertower HamburgTrumpf DitzingenEnergy Bunker Hamburg-WilhelmsburgKarlsruhe, Mannheimer Str. 13+15Hahn und Kolb Stuttgart

Quality

The function of the SÜLA systems is demonstrated by scientifically verified real-fire tests; acceptance is carried out by recognised experts. In addition, hot smoke tests with three high-performance fog machines are used to visually demonstrate the system function.

EvidenceKaufungen
Hot smoke test for acceptance
Commissioning and acceptance
Maintenance service
ISO 9001

History

  1. 1946

    Foundation of Heinz Horch GmbH, originally a roofing business

  2. 1954

    First ventilation ducts made of fibre cement

  3. 1960

    New production facility in Guxhagen near Kassel, approx. 150 employees

  4. 1971

    Foundation of conit Lufttechnik GmbH

  5. 1976

    Heinz Horch passes away; Günter and Rosemarie Horch take over management

  6. 1979

    Move into the new administration and production building in Kassel

  7. 1981

    Development of asbestos-free ventilation ducts

  8. 1986

    Ingrid and Günter Horch continue to run the company

  9. 1994

    Foundation of PAFAMAX Brandschutz GmbH; first SÜLA systems

  10. 1997

    New production hall for the PAFAMAX fire protection round duct system (later Geberit Aerotec 90)

  11. 2000

    1,000,000 residential units equipped with conit residential ventilation; market leader in residential ventilation with fire protection

  12. 2005

    Insolvency of the corporate group; foundation of Fabian Horch industrial representation

  13. 2010

    Fabian Horch founds FAHO GmbH

  14. 2012

    Restructuring: all processes from sales to maintenance handled by FAHO

  15. 2013

    Move into the production and administration building in Kaufungen; first hot smoke tests

  16. 2014

    Development of new techniques for fire-protected stairwells

  17. 2015

    Günter Horch leaves the company

  18. 2016

    First systems with actively controlled exhaust

  19. 2018

    More than 1,000 engineered and executed SÜLA systems

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo