Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
Fluigent – Fertigung

Development and manufacturing of pressure-based microfluidic flow controllers, OEM components and automated Organ-on-Chip platforms.

Fluigent Logo

Fluigent

Paris (FR) · Fukuoka (JP, Distributor ASICON Tokyo)New on Amplifa

2005Founded
60Employees worldwide
20Patents
2Subsidiaries
12Distributors worldwide

About Fluigent

Fluigent was founded in 2005 by researchers from the Institut Curie in Paris and was the first company to introduce pressure-based flow control for microfluidics research. The company develops, manufactures and supports fluid control systems for micro- and nanofluidics with applications in droplet, cell biology and particle studies. Manufacturing goes beyond mere assembly: Fluigent masters the algorithmic, mechanical, electronic, pneumatic and microfluidic value chains in-house. Product portfolio: pressure controllers (Flow EZ™, MFCS-EZ), F-OEM series OEM pressure controllers, the non-intrusive NIFS flow sensor, the automated Aria injection system and the Omi Organ-on-Chip platform. With around 60 employees from 10 nations, 20 patents, two subsidiaries (including Fluigent Germany) and 12 distributors, Fluigent supplies research laboratories and industry worldwide; customers include ESPCI/IPGG and the University of Cambridge.

Site
Paris
Processes
Pressure-based microfluidic flow controller (pressure-based flow control), Pressure pumps / pressure-controlled liquid regulation for microfluidics, Droplet generation (droplet microfluidics), Organ-on-a-Chip perfusion and cell culture (automated platform), Microfluidic recirculation system (recirculation/perfusion), Non-intrusive flow sensing (calibration-free), Double emulsion/microencapsulation (encapsulation, RayDrop-based platform), OEM component development and system development for fluid control systems
Materials
Alginate, PLGA, PEGDA, PMMA
Certificates
Internal quality process management
Founded
2005
Employees
60
Industries
Life Sciences, Biotechnology, Pharmaceuticals, Cosmetics, Food, Water management
  1. 01

    R&D (electronics, mechanics, pneumatics, software, fluidics)

  2. 02

    Prototyping of proprietary OEM technologies

  3. 03

    Product design and manufacturing

  4. 04

    Assembly and quality assurance

  5. 05

    OEM integration and system development

  6. 06

    Support, repair and training

Materials & Processes

PMMA

PMMA

Polymer substrate for microfluidic chips and fluidic components.

PEGDA

PEGDA

UV-crosslinkable hydrogel for microencapsulation and biomaterials

PLGA

PLGA

Biocompatible polymer for microencapsulated drug particles.

ALG

Alginate

Hydrogel for microbeads, e.g. spheroid encapsulation.

Locations

Standort Paris

Paris

FR

Headquarters, development and production

Materials
Plastics
  • Pressure-based flow controller Flow EZ™ (in-house production)
  • F-OEM OEM pressure controller
  • NIFS flow sensor
  • Omi Organ-on-Chip platform
  • Aria injection system

Fukuoka

JP

Distributor ASICON Tokyo

Components & Products

Flow EZ™ microfluidic flow controller
Flow EZ™ microfluidic flow controllerPressure-based flow control · Research & industry
Omi Organ-on-Chip platform
Omi Organ-on-Chip platformAutomated perfusion · Life sciences
Microencapsulation system (RayDrop)
Microencapsulation system (RayDrop)Double emulsion · Cosmetics/pharma
OEM fluidic valve automation system
OEM fluidic valve automation systemF-OEM integration · Diagnostics

Inside the production

Microfluidic controller product line
Microfluidic controller product line
Microfluidic chip
Microfluidic chip
Custom microfluidic device
Custom microfluidic device
Cross-section of a two-channel Organ-on-Chip
Cross-section of a two-channel Organ-on-Chip

Industries

Life SciencesBiotechnologyPharmaceuticalsCosmeticsFoodWater managementDiagnosticsSemiconductorsSemiconductors/Diagnostics

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Pressure-based microfluidic flow controller (pressure-based flow control)Engineering–––––
Pressure pumps / pressure-controlled liquid regulation for microfluidicsEngineering–––––
Droplet generation (droplet microfluidics)EngineeringMonodispersity CV < 2%––––
Organ-on-a-Chip perfusion and cell culture (automated platform)Engineering–––––
Microfluidic recirculation system (recirculation/perfusion)Engineering––––Plastics
Non-intrusive flow sensing (calibration-free)Testing5% of measured value––––
Double emulsion/microencapsulation (encapsulation, RayDrop-based platform)EngineeringDroplet size 25 µm to 450 µm outer diameter–––Alginate, PLGA, PEGDA, PMMA
OEM component development and system development for fluid control systemsEngineering–––––
Microfluidic temperature controlEngineering–––––
Liquid stirring solutions (Liquid Stirring)Engineering–––––
Automated sequential injection (immunolabeling/perfusion)Engineering–––––

7 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Pressure-based flow controllerFluigent Flow EZ™––––
OEM pressure controllerFluigent F-OEM––––
Automated Organ-on-Chip platformFluigent Omi––––
Automated sequential injection systemFluigent Aria––––
Double emulsion droplet generatorSecoya Technologies RayDrop Double Emulsion Device––––
Non-intrusive flow sensor (NIFS)Fluigent NIFS–99.85 x 45.00 x 33.50 mm; 100 µL/min to 10 mL/min; max. 2 bar––
Pressure controller (premium class)Fluigent MFCS-EZ––––

Additional services

OEM components and system developmentEngineering services for fluid handlingCustomer support and device repairAdaptation/customization of systemsWorkshops and webinarsTraining and consulting

Reference customers

ESPCI Paris (MMN Laboratory, IPGG)University of CambridgeUniversity College LondonUniversity of ManchesterImperial College LondonUniversity of OxfordInstitut Pasteur de LilleUniversity of Hong KongIPGG Pierre-Gilles de Gennes InstituteNIST (workshop partner)Secoya TechnologiesRAN Biotechnologies

Quality

Fluigent publishes insights into its quality process for the maintenance of pressure controllers; the NIFS sensor operates calibration-free with an accuracy of 5% of the measured value.

EvidenceParis
Internal quality process management

History

  1. 2005

    Founded by researchers from the Institut Curie in Paris; first company with pressure-based flow control for microfluidics research

  2. 2010

    First µTAS exhibition in Groningen

  3. 2014

    Founding of Fluigent Germany

  4. 2021

    15th anniversary, awarded Exporter of the Year Île-de-France, launch of the OxyGEN software

  5. 2022

    Launch of the F-OEM series; Aria featured in Nature Methods/Nature Protocols; German website launched

  6. 2023

    Launch of the Omi Organ-on-Chip platform

  7. 2026

    20th company anniversary; Scientific Challenge; participation in MicroTAS 2026

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo