Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
FRAKO – Fertigung

Capacitors, reactive power compensation systems, power quality and energy management solutions from Teningen

FRAKO Logo

FRAKO Kondensatoren- und Anlagenbau GmbH

Teningen · GermanyNew on Amplifa

1928Founded
Over 120Employees
17,5–500 kvar per cabinetPower range of compensation systems
35–277 kvar per cabinetHybrid compensation HPQ

About FRAKO

FRAKO Kondensatoren- und Anlagenbau GmbH, headquartered in Teningen (Baden-Württemberg), has been developing and manufacturing power capacitors, reactive power compensation systems, filter solutions and energy management systems since 1928. The product range includes detuned and non-detuned compensation systems (17,5 to 500 kvar per cabinet), dynamic systems with thyristor switches (LSFC-E, 100 to 300 kvar), electronic hybrid compensation (HPQ, 35 to 277 kvar), active and passive harmonic filters, as well as measuring and monitoring devices of the PQA series. The dry-technology power capacitors are manufactured in-house with self-healing segmented capacitor film, an overpressure disconnect device and patented contact ring technology; systems are assembled modularly in sheet-steel switch cabinets. Services include grid analyses by VDE-certified PQ experts, project planning, commissioning, maintenance, retrofits and training. Customers come from industry and trade, energy supply, rail transport, data centers and building technology; projects have been delivered, among others, to Siemens Mobility in Bulgaria.

Site
Teningen
Processes
Manufacture of power capacitors (self-healing capacitor film, segmented film,, Manufacture of reactive power compensation systems (non-detuned and detuned, 17,5 to 500 kvar, Manufacture of dynamic reactive power compensation systems LSFC-E (100 to 300 kvar,, Manufacture of inductive reactive power compensation systems LSI (fixed stage, controlled system,, Electronic reactive power compensation HPQ (Hybrid Power Quality, 35 to 277 kvar per cabinet,, Active harmonic filters (compensation up to the 49th harmonic, floor-standing cabinet or, Passive filter systems for low-voltage grids with high harmonic content, Power electronics capacitors type series LKT-F (for DC and AC voltage applications)
Materials
Sheet steel, Aluminum, Self-healing capacitor film (metallized plastic film), Lead-free contacts (contact ring technology), Self-healing metallized capacitor film, Inductive components (shunt and filter circuit reactors)
Certificates
ISO 9001, ISO 14001, ISO 50001
Founded
1928
Employees
>100
Industries
Industry and trade, Energy supply / grid operators, Renewable energies / solar parks, Public transport / rail, Building technology, Data centers
  1. 01

    Grid analysis / power quality measurement (VDE-certified)

  2. 02

    Consulting and project planning

  3. 03

    Manufacture of power capacitors

  4. 04

    System construction and switch cabinet manufacturing

  5. 05

    Factory acceptance and final inspection

  6. 06

    On-site commissioning

  7. 07

    Maintenance, retrofit and remote maintenance

Materials and Technologies

Folie

Self-healing metallized capacitor film

Used in power capacitors with segmented film and overpressure disconnect device for maximum operational safety.

Stahlblech

Sheet steel

Enclosures and cabinets for wall and floor mounting of compensation systems and filter systems.

Al

Aluminum

Used in capacitor manufacturing, among other things for contact ring technology in lead-free capacitors.

LSI

Inductive components (shunt and filter circuit reactors)

Used in inductive and dynamic compensation systems for grids with harmonic distortion.

Locations

Standort Teningen

Teningen

DE

Headquarters with administration, development, capacitor and system manufacturing

Materials
Capacitor film, sheet steel, aluminum
  • Production hall for capacitor manufacturing (2005)
  • Switch cabinet and system construction

Products and Components

Reactive power compensation system LSFC
Reactive power compensation system LSFCSystem construction · Industry, trade
Dynamic compensation system LSFC-E
Dynamic compensation system LSFC-EThyristor switching · Rail transport
Power capacitor LKT
Power capacitor LKTDry technology · Power quality
Active harmonic filter
Active harmonic filterFilter technology · Low-voltage grids
Inductive compensation system LSI
Inductive compensation system LSIHybrid compensation · Energy supply

Inside the production

FRAKO headquarters in Teningen
FRAKO headquarters in Teningen
Employees at the company
Employees at the company
Development and project planning
Development and project planning
On-site service
On-site service
Training in the company's own training center
Training in the company's own training center

Industries

Industry and tradeEnergy supply / grid operatorsRenewable energies / solar parksPublic transport / railBuilding technologyData centersBanks and insurance companiesMetal processingFood / breweriesPlastics processingEnergy utilities / grid operatorsPublic transport systems (railway, subway)Banks and insurance companies / administrations

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Manufacture of power capacitors (self-healing capacitor film, segmented film,Assembly––––Capacitor film, Aluminum
Manufacture of reactive power compensation systems (non-detuned and detuned, 17,5 to 500 kvarAssembly––––Sheet steel
Manufacture of dynamic reactive power compensation systems LSFC-E (100 to 300 kvar,Assembly––––Sheet steel
Manufacture of inductive reactive power compensation systems LSI (fixed stage, controlled system,Assembly–––––
Electronic reactive power compensation HPQ (Hybrid Power Quality, 35 to 277 kvar per cabinet,Assembly––––Sheet steel
Active harmonic filters (compensation up to the 49th harmonic, floor-standing cabinet orAssembly–––––
Passive filter systems for low-voltage grids with high harmonic contentAssembly–––––
Power electronics capacitors type series LKT-F (for DC and AC voltage applications)Assembly–––––
Energy management systems (PQA series, PQM, EM-MC2200, EMVIS software)Engineering–––––
Grid analysis / power quality measurement (certified PQ analyses according to VDE)Testing–––––
Project planning, design and commissioning of compensation systems, filters, sinus/IHF filters,Engineering–––––
Capacitor final inspection (routine tests according to IEC/EN 60831, type tests, release tests,Testing–––––
Commissioning service, maintenance, repair, spare parts, retrofit andAssembly–––––

1 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
System construction / switch cabinet manufacturing (production hall for capacitor manufacturing)FRAKO––2005Teningen

Additional services

ConsultingGrid analysis / power quality measurement (VDE-certified experts)Project planning and design of compensation, filter and energy management systemsCommissioning serviceInspection and maintenance serviceRepair service (also for systems from other manufacturers)Spare parts serviceRetrofit serviceCondition monitoring serviceRemote maintenance / technical supportTrainingFilter loan test

Reference customers

Siemens Mobility (Bulgaria)Badische Staatsbrauerei RothausRavago Plastics Deutschland GmbH

Quality

Every production stage is subject to quality controls: capacitors undergo routine tests in accordance with IEC/EN 60831, type tests, FRAKO release tests, and inspections before, during and after production; each capacitor is linked via an individual serial number to the test results of the final inspection.

EvidenceTeningen
ISO 9001
ISO 14001
ISO 50001

History

  1. 1928

    Founded in Frankfurt as 'Frankfurter Kondensatorenfabrik'

  2. 1932

    Relocation of headquarters to Teningen

  3. 1949

    Start of production of capacitors for fluorescent lamps and power capacitors

  4. 1957

    Start of manufacturing automatically controlled reactive power compensation systems

  5. 1975

    Introduction of the first electronic reactive power controller

  6. 1984

    Introduction of the LKI power capacitor, PCB-free with overpressure disconnect protection

  7. 1989

    Discontinuation of electrolytic capacitor production, sale to Roederstein

  8. 1992

    Presentation of the first energy management system

  9. 1995

    Patent for screwless terminal with spring clamp technology; subsidiary of Berliner Elektro Holding AG

  10. 1998

    Market launch of dynamic compensation systems with thyristor switches

  11. 1999

    Introduction of the 'dry' high-power capacitor LKT; ISO-14001 certification

  12. 2002

    Introduction of the FRAKO C module

  13. 2005

    New production hall for capacitor manufacturing; acquisition by BET GmbH / AdCapital AG

  14. 2012

    Certification of energy management to ISO 50001; UL certification of LKT capacitors for North America

  15. 2013

    Founding of frako power systems GmbH & Co. KG (CHP)

  16. 2015

    Patented contact technology for power capacitors

  17. 2016

    Introduction of the Power Quality Controller PQC

  18. 2017

    Introduction of the Power Quality Manager PQM 1588 (Industry 4.0 / OPC UA)

  19. 2020

    Market launch of power electronics capacitors (LKT-F)

  20. 2023

    Delivery of a dynamic reactive power compensation system to Siemens Mobility in Bulgaria

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo