Development and manufacture of hydrogen reference electrodes, pH electrodes, electrochemical measuring cells and measuring systems.

Gaskatel Gesellschaft für Gassysteme durch Katalyse und Elektrochemie mbH
Kassel (Headquarters)New on Amplifa
About Gaskatel
Gaskatel GmbH, based in Kassel, develops and manufactures electrochemical measuring products: hydrogen reference electrodes (HydroFlex, Mini-HydroFlex, Mini-HydroFlex Pro), pH electrodes without glass membrane (pHydrunio), electrochemical test cells (FlexCell-PTFE, FlexCell-PP, ElyFlow), gas diffusion electrodes as well as measuring and control units such as ElyControl and Temperature Control Box. The company's reference electrode is the only commercially available hydrogen reference electrode that complies with the IUPAC recommendations. Founded in 1997 by members of Prof. Winsel's working group at the University of Kassel, the company combines expertise from physics, chemistry and engineering and serves universities, research institutes and industrial R&D laboratories worldwide. In addition to its standard products, Gaskatel develops customized electrochemical measuring systems and offers measuring and testing services, from conducting experiments to result interpretation, including corrosion measurements. Products are sold via an online shop and an international distributor network.
- Site
- Kassel
- Processes
- Development and manufacture of hydrogen reference electrodes (HydroFlex, Mini-HydroFlex,, Development and manufacture of electrochemical measuring cells (FlexCell-PTFE, FlexCell-PP, ElyFlow), Development and manufacture of pH electrodes (pHydrunio, hydrogen pH electrode without glass, Development and manufacture of gas electrodes/gas diffusion electrodes (NiH33, MOC, PerOx, Pla-CC), Development and manufacture of electrochemical measuring systems and control units (Control Box, Custom electrochemical measuring systems (Custom Electrochemical Systems), Electrochemical measuring and testing services (conducting experiments, interpretation of, Measuring and testing services
- Materials
- Polypropylene (PP), PTFE, PFA, Platinum, Nickel catalyst, Nafion membrane N424, TPE (hose material), FEP (insulated Pt-100 temperature sensors)
- Certificates
- CE conformity (products)
- Founded
- 1997
- Industries
- Research and universities, Industrial R&D, Electrochemistry, Corrosion research
- 01
Development and design
- 02
Manufacturing of measuring cells and electrodes
- 03
Assembly of measuring systems and control units
- 04
Testing and calibration
- 05
Distribution via online shop and distributors
- 06
Technical support and measuring services
Materials and Construction Materials
Polypropylene (PP)
Used for housing heads of the reference electrodes and the FlexCell-PP test cell, offering good resistance and durability.
PTFE
Highly chemically resistant material for test cells such as FlexCell-PTFE and electrode components.
PFA
Insulating and construction material for cell components and temperature sensors in contact with the electrolyte.
Platinum
Catalyst and electrode material of the hydrogen reference electrodes and platinum catalyst electrodes (Pla-CC).
Nickel catalyst
Catalyst material of the gas diffusion electrodes such as NiH33.
Nafion membrane N424
Standard separator for separating the anolyte and catholyte chambers in the ElyFlow test cell.
TPE (hose material)
Hose material for electrolyte pumps in the measuring systems.
FEP
Insulation of the Pt-100 temperature sensors in the control units.
Locations

Kassel
DEHeadquarters, development, manufacturing and sales
- Materials
- Polypropylene (PP), PTFE, PFA, platinum, nickel catalyst
Products and Components






Inside the production






Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Development and manufacture of hydrogen reference electrodes (HydroFlex, Mini-HydroFlex,Engineering | – | – | – | – | Polypropylene (PP), PTFE, Platinum |
| Development and manufacture of electrochemical measuring cells (FlexCell-PTFE, FlexCell-PP, ElyFlow)Engineering | – | – | – | – | PTFE, PFA, Polypropylene (PP) |
| Development and manufacture of pH electrodes (pHydrunio, hydrogen pH electrode without glassEngineering | – | – | – | – | – |
| Development and manufacture of gas electrodes/gas diffusion electrodes (NiH33, MOC, PerOx, Pla-CC)Engineering | – | – | – | – | Nickel catalyst, Platinum |
| Development and manufacture of electrochemical measuring systems and control units (Control BoxEngineering | – | – | – | – | – |
| Custom electrochemical measuring systems (Custom Electrochemical Systems)Engineering | – | – | – | – | – |
| Electrochemical measuring and testing services (conducting experiments, interpretation ofTesting | – | – | – | – | – |
Additional services
Quality
The products are developed, manufactured and tested on the basis of the company's own laboratory experience; CE declarations of conformity for reference electrodes, pH electrodes, cells and control units are available. Analytical measurements and a highly experienced specialist team ensure reliable measurement results and support by telephone and e-mail.
| Evidence | Kassel |
|---|---|
| CE conformity (products) |
History
- 1997
Founding of Gaskatel GmbH by members of Prof. Winsel's working group at the University of Kassel.
Development of the world's only commercially available IUPAC-compliant hydrogen reference electrode.
- 2025
Introduction of the Mini-HydroFlex Pro with a more pressure-resistant design, 1/4"-28-UNF thread and PP head.