Flow measurement technology for liquids and gases: measuring instruments, valves, display electronics and mobile measurement services.

H. Hermann Ehlers GmbH
Oyten (28876, An der Autobahn 45)New on Amplifa
About us – Flow measurement technology since 1865
H. Hermann Ehlers GmbH is a specialist wholesaler and system provider for flow measurement technology headquartered in Oyten near Bremen. The product range includes flow meters such as electromagnetic flow meters (MID), ultrasonic flow meters in clamp-on and inline versions, nutating disc meters, oval gear meters, paddle wheel and Woltman meters, turbine and variable-area flow meters as well as oscillating piston and shunt rotor meters. The range is complemented by valves (control valves, backflow prevention devices, shut-off valves, pinch valves), display electronics and dosing/filling controls, totalizing counters, heat meters as well as filters and pumps. In addition to consulting and sales, the company offers mobile ultrasonic clamp-on measurement services and rental devices, dosing controls, repairs and energy management software. Main applications are fuel measurement and viscosity control in shipbuilding, drinking water and wastewater technology, power plants, petrochemicals, building and HVAC technology as well as municipalities.
- Site
- Oyten
- Processes
- Mobile ultrasonic clamp-on flow measurement (measurement service, transit-time method), Rental of the FLUXUS F601 mobile ultrasonic flow meter, Consulting and sales of flow measurement technology (measuring, controlling, pumping), Installation of SL13 backflow flap (Stop Silent Light) in inspection shaft, Repairs of flow meters, Consulting on flow measurement, control and pumping, Mobile ultrasonic flow measurement service (clamp-on, FLUXUS F601), Rental of mobile ultrasonic flow meters
- Materials
- Stainless steel, Grey cast iron, Brass, Cast, Aluminium, Spheroidal graphite iron GGG-50, Kynar, Ryton
- Founded
- 1865
- Industries
- Shipbuilding (fuel measurement, viscosity control), Drinking water and wastewater, Power plants, Petrochemicals, Food industry, Building/HVAC, climate control and refrigeration technology
- 01
Consulting on the measurement task
- 02
Selection and distribution of measuring instruments and valves
- 03
Accessories and display electronics/dosing controls
- 04
Mobile measurement services or rental devices
- 05
Installation (e.g. SL13 backflow prevention)
- 06
Repair and service services
Materials
Stainless steel
Housing material of nutating disc meters for heating oil and industry.
Spheroidal graphite iron GGG-50
Material of the KSF single filter for gaseous and liquid media.
Grey cast iron
Housing material of oil meters (VZO series).
Brass
Housing material of oil meters, up to 180 °C and 40 bar.
Aluminium
Piston material in nutating disc meters.
Kynar (PVDF)
Piston material for chemically demanding media.
Ryton (PPS)
Piston material for the OP series.
Ultem (PEI)
Piston material for the OP series.
Teflon (PTFE)
Piston material in the ARD series.
Solid rubber / membrane
Material of pinch valves and backflow flaps (TideFlex, SL13).
Graphite / hard rubber
Piston material in the ARD series.
Locations

Oyten
DEHeadquarters, sales and service
- FLUXUS F601 mobile clamp-on ultrasonic flow meter (Flexim)
- FLUXUS F631 mobile ultrasonic flow and heat metering device
Components and products






Inside the production


Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Mobile ultrasonic clamp-on flow measurement (measurement service, transit-time method)Testing | Measurement accuracy typically 1–3 % of measured value | – | – | – | Liquids |
| Rental of the FLUXUS F601 mobile ultrasonic flow meterTesting | – | – | – | – | Liquids |
| Consulting and sales of flow measurement technology (measuring, controlling, pumping)Engineering | – | – | – | – | – |
| Installation of SL13 backflow flap (Stop Silent Light) in inspection shaftAssembly | Backflow prevention up to 0.5 bar (5 m backflow head) | – | under 1 KG (valve weight) | – | – |
| Repairs of flow metersTesting | – | – | – | – | – |
2 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Mobile clamp-on ultrasonic flow meter | Flexim FLUXUS F601 | 1 | Pipe inner diameter up to DN 250 (fuel measurement); temperature -40...+200 °C, with WaveInjector | – | Oyten |
| Mobile ultrasonic flow and heat metering device | Flexim FLUXUS F631 | – | Pipe inner diameter 6 to 6500 mm | – | – |
Additional services
History
- 1865
First registration of the Ehlers company on 18 September 1865 by Hermann Heinrich Ehlers in the Bremen commercial register.
- 1909
Johannes Ferdinand Ehlers takes over the company and runs it until his death in 1947.
- 1950
Hermann Ehlers becomes a member of the CDH on 01.07.1950 (over 50 years of membership).
- 1960
Due to proximity to the port, contacts with shipbuilding; worldwide contacts especially in fuel measurement up to DN 250 and viscosity control.
- 1980
Hermann Ehlers dies; previously the company had focused on its core business of flow measurement of liquids and gases, cooperating among others with Aquametro AG.
- 1981
Foundation of H. Hermann Ehlers GmbH on 01.01.1981 by Etta Blecker and Gisa Dohmeier.
- 2001
Marc Blecker becomes a member of the management.
- 2011
After the death of Etta Blecker, Marc Blecker becomes sole managing director/shareholder.