Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
HESTO – Fertigung

Development and manufacture of thermal conductivity measuring instruments (HLC) for insulation material production

HESTO Logo

Hesto Elektronik GmbH

Langen near Frankfurt (DE)New on Amplifa

1970Founded
more than 50Years on the market
±3 %Measurement accuracy according to ISO 8301
20–200 minMeasurement time depending on specimen thickness and

About HESTO

Hesto Elektronik GmbH, based in Langen near Frankfurt, has been developing and manufacturing industrial measurement technology since 1970. Its core business is HLC thermal conductivity measuring instruments as heat flow meter devices in accordance with ISO 8301, EN 12667, EN 1946-3 and EN 12664 for determining the thermal conductivity of insulation materials. The portfolio includes floor-standing and benchtop devices for specimens from 200×200 mm to 500×500 mm as well as automatic specimen feeding systems (RSH2/RSH3/RSH5) for 24-hour continuous operation. The instruments are used in in-house quality control of insulation material production by manufacturers in Europe and beyond, as well as in building-authority-approved testing institutes such as FIW Munich, EMPA and LNE. Electronic modules are sourced from specialists; the functions are programmed and the devices, including the mechanics, are manufactured entirely in-house. In addition to device sales, HESTO offers thermal conductivity measurements as a service, along with consulting, support, maintenance and free software updates under a maintenance contract.

Site
Langen near Frankfurt
Processes
Thermal conductivity measurement (heat flow meter device, ISO 8301/EN 12667/EN, Thermal conductivity measurement as a service, Consulting, support and maintenance from the manufacturer, Software updates, Financing options, Automatic specimen feeding systems (RSH2/RSH3/RSH5)
Materials
Heat Flow Meter method, Automatic specimen feeding systems RSH2/RSH3/RSH5
Certificates
Calibration with reference material from the accredited external monitoring, Long-term stable test specimen for verification, 3-year factory warranty
Founded
1970
Industries
Insulation material production, Materials testing, Testing institutes (MPA, FIW)
  1. 01

    Development and design of the measuring instruments

  2. 02

    Procurement of the electronic modules

  3. 03

    Programming of the functions including proprietary software

  4. 04

    Mechanical manufacturing and device assembly

  5. 05

    Calibration with reference material (FIW, EMPA, LNE)

  6. 06

    Direct sales, support, maintenance and software updates

  7. 07

    Thermal conductivity measurement as a service

Methods & Standards

HFM

Heat Flow Meter method

Measurement in accordance with ISO 8301, EN 12667, EN 1946-3 and EN 12664 with ± 3 % accuracy; two sensors in a symmetric arrangement deliver voltage signals proportional to the heat flow.

RSH

Automatic specimen feeding systems RSH2/RSH3/RSH5

Feeding automation for one or two HLC measuring instruments for decoupled continuous monitoring.

Locations

Standort Langen

Langen

DE

Development, manufacturing and sales

Lot size
Single units and small series, no large series
Materials
Industrial measurement technology
  • HLC X520
  • HLC X310
  • HLC X206
  • HLC T520
  • HLC T310
  • HLC T206
  • HLC A310
  • HLC A206
  • RSH2/RSH3/RSH5

Devices & Systems

HLC X520 thermal conductivity measuring instrument (floor-standing unit, 500×500 mm, 10–50 °C)
HLC X520 thermal conductivity measuring instrument (floor-standing unit, 500×500 mm, 10–50 °C)Heat Flow Meter · Insulation material production
HLC X310 thermal conductivity measuring instrument (floor-standing unit, 300×300 mm, 10–50 °C)
HLC X310 thermal conductivity measuring instrument (floor-standing unit, 300×300 mm, 10–50 °C)Heat Flow Meter · Insulation material production
HLC A310 thermal conductivity measuring instrument (benchtop unit, 300×300 mm, 23 °C)
HLC A310 thermal conductivity measuring instrument (benchtop unit, 300×300 mm, 23 °C)Heat Flow Meter · Materials testing
HLC A206 thermal conductivity measuring instrument (benchtop unit, 200×200 mm, 23 °C)
HLC A206 thermal conductivity measuring instrument (benchtop unit, 200×200 mm, 23 °C)Heat Flow Meter · Materials testing
Automatic specimen feeding system RSH
Automatic specimen feeding system RSHFeeding automation · In-house quality control

Inside the production

Software and evaluation on a laptop
Software and evaluation on a laptop
HLC device family
HLC device family

Industries

Insulation material productionMaterials testingTesting institutes (MPA, FIW)

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Thermal conductivity measurement (heat flow meter device, ISO 8301/EN 12667/ENTestingMeasurement accuracy ± 3 %500 mm × 500 mm × 200 mm (specimen thickness)––Insulation materials
Thermal conductivity measurement as a serviceTesting––––Insulation materials

9 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Thermal conductivity measuring instrument (floor-standing unit)HESTO HLC X520–500*500mm insulation boards between 20...200mm thickness, test temperature 10°C to 50°C–Langen near Frankfurt
Thermal conductivity measuring instrument (floor-standing unit)HESTO HLC X310–300*300mm insulation boards between 15...100mm thickness, test temperature 10°C to 50°C–Langen near Frankfurt
Thermal conductivity measuring instrument (floor-standing unit)HESTO HLC X206–200*200mm insulation boards between 15…60mm thickness, test temperature 10°C to 50°C–Langen near Frankfurt
Thermal conductivity measuring instrument (floor-standing unit)HESTO HLC T520–500*500mm insulation boards between 20...200mm thickness, test temperature 10°C–Langen near Frankfurt
Thermal conductivity measuring instrument (floor-standing unit)HESTO HLC T310–300*300mm insulation boards between 15...100mm thickness, test temperature 10°C–Langen near Frankfurt
Thermal conductivity measuring instrument (floor-standing unit)HESTO HLC T206–200*200mm insulation boards between 15...60mm thickness, test temperature 10°C–Langen near Frankfurt
Thermal conductivity measuring instrument (benchtop unit)HESTO HLC A310–300*300mm insulation boards between 15...100mm thickness, test temperature 23°C–Langen near Frankfurt
Thermal conductivity measuring instrument (benchtop unit)HESTO HLC A206–200*200mm insulation boards between 15...60mm thickness, test temperature 23°C–Langen near Frankfurt
Automatic specimen feeding systemHESTO RSH2/RSH3/RSH5–for one or two HLC measuring instruments–Langen near Frankfurt

Additional services

Thermal conductivity measurement as a serviceConsulting, support and maintenance from the manufacturerSoftware updatesFinancing optionsAutomatic specimen feeding systems (RSH2/RSH3/RSH5)

Reference customers

FIW MunichEMPALNE

Quality & Reproducibility

Calibration is performed using reference material from the accredited external monitoring bodies (FIW, EMPA, LNE, materials testing institutes). In practice, the reproducibility tolerance is well below ± 1 %; correct functioning can be verified at any time by re-measuring a supplied, long-term stable test specimen.

EvidenceLangen
Calibration with reference material from the accredited external monitoring
Long-term stable test specimen for verification
3-year factory warranty

History

  1. 1970

    Start of industrial measurement technology in Langen near Frankfurt with the development and manufacture of in-house amplifiers, analog and microprocessor modules including mechanics.

  2. ca. 1995

    For about 30 years, HLC analyzers have become the standard in in-house quality control of insulation material production at manufacturers in Europe and beyond.

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo