Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search

Engineering consultancy for structural dynamics: vibration measurements, vibration monitoring according to DIN 4150 and dynamic calculations

IF

iff – Ingenieurbüro für Dynamik und Erschütterungen Dr.-Ing. Matthias Fritsche

BerlinNew on Amplifa

1996Founded
Mandatory member Berlin Chamber ofChamber membership
Sole proprietorshipLegal form
30 sensors in parallel (referenceMeasurement equipment scope

About the engineering consultancy

The engineering consultancy iff has been working in the field of structural dynamics since 1996 with vibration measurements, calculations and consulting. Core services include Class 1 vibration measurements according to DIN 4150/45669 as well as vibration monitoring of buildings and structures according to DIN 4150-3 and DIN 4150-2, for example during demolition, vibration, compaction and foundation works. For planned construction projects, vibration forecasts are prepared based on site measurements; where exceedances are expected, structural measures or active and passive vibration isolation using spring elements and elastomers are calculated and systems planned. In addition, the consultancy offers pile integrity testing, structure-borne-sound-intensive building acoustics analyses, structural and foundation dynamics calculations of stiffnesses, natural frequencies and damping, as well as site investigations. Clients come from construction, rail transport, public building, trade fairs and laboratory or production technology. The consultancy is based in Berlin and is led by founder Dr.-Ing. Matthias Fritsche.

Site
Berlin
Processes
Class 1 vibration measurements according to DIN 4150/45669, Vibration monitoring of buildings/structures according to DIN 4150, Vibration forecasts, calculations, system planning, Site investigations / immission forecasts for construction projects, Calculation of active/passive vibration isolation, Pile integrity testing, Structure-borne sound analyses / building acoustics measurements, Serviceability measurements on bridges
Materials
Vibrations in buildings – Effects on structures, Vibrations in buildings – Effects on people in buildings, Measurement equipment for vibration measurements (Class 1)
Certificates
Measurement equipment according to DIN 45669 (Class 1), Certified quality management system
Founded
1996
Industries
Construction/geotechnics, Rail transport, Trade fairs/events, Laboratory and production technology, Public construction, Public construction (Bundestag, museums)
  1. 01

    Site investigation or on-site vibration measurement

  2. 02

    Evaluation and derivation of dynamic parameters or immissions

  3. 03

    Vibration forecast or assessment according to DIN 4150-2/-3

  4. 04

    Calculation of measures (isolation, structural modifications)

  5. 05

    Vibration monitoring with alarm during construction works

  6. 06

    Report and documentation

Measurement methods and standards

DIN 4150-3

Vibrations in buildings – Effects on structures

Guide values and procedures for verifying the protection of neighbouring buildings during construction works.

DIN 4150-2

Vibrations in buildings – Effects on people in buildings

Assessment and avoidance of significant vibration nuisance to people in residential premises.

DIN 45669

Measurement equipment for vibration measurements (Class 1)

Normative basis for the monitoring systems and amplifiers used.

Location

Berlin

DE

Office

Materials
Class 1 vibration measurements according to DIN 4150/45669, vibration monitoring according to DIN 4150-2/-3,
  • Monitoring systems DIN 45669-C15HV80/1
  • Amplifiers DIN 45669-A12HV80/1

Industries

Construction/geotechnicsRail transportTrade fairs/eventsLaboratory and production technologyPublic constructionPublic construction (Bundestag, museums)

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Class 1 vibration measurements according to DIN 4150/45669Testing–––––
Vibration monitoring of buildings/structures according to DIN 4150Testing–––––
Vibration forecasts, calculations, system planningEngineering–––––
Site investigations / immission forecasts for construction projectsEngineering–––––
Calculation of active/passive vibration isolationEngineering–––––
Pile integrity testingTesting–––––
Structure-borne sound analyses / building acoustics measurementsTesting–––––
Serviceability measurements on bridgesTesting–––––
Structural dynamics calculations and consulting (dynamics, foundation engineering/soil dynamics)Engineering–––––

4 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Monitoring system according to DIN 45669DIN 45669-C15HV80/12––Budapester Straße 35 Berlin (deployment)
Amplifier according to DIN 45669DIN 45669-A12HV80/11––EÜ Wiesenweg (deployment)
Monitoring system according to DIN 45669DIN 45669-C15HV80/13––EÜ Wiesenweg (deployment)
Monitoring system according to DIN 45669DIN 45669-C15HV80/13––Demolition of Deutschlandhalle (deployment)

Additional services

Vibration measurements (Class 1 according to DIN 4150/45669)Vibration monitoring according to DIN 4150-3 and DIN 4150-2Vibration forecasts for construction projectsStructural dynamics calculations (stiffnesses, natural frequencies, damping)Calculation of active/passive vibration isolation (spring elements, elastomers)Consulting on dynamic problemsPile integrity testingBuilding acoustics/structure-borne sound analyses (e.g. elevator systems)Site investigations

Reference customers

AVG Nord GmbHEchterhoff Bau GmbH & Co. KG, NL BerlinDB Netze AG, Regionalbereich OstFederal Office for Building and Regional Planning (BBR)Messe BerlinState Museums of Berlin (SMB)

Measurement and testing technology

The measurements are carried out with monitoring systems and amplifiers according to DIN 45669 Class 1; continuous monitoring uses UPS backup, alarm circuits and empirical evaluation methods based on long-term experience.

EvidenceBerlin
Measurement equipment according to DIN 45669 (Class 1)
Certified quality management system

History

  1. 1996

    Foundation of the engineering consultancy faust & fritsche (iff) with a focus on dynamics and foundation engineering/soil dynamics

  2. 2000

    Addition of the acoustics and noise protection fields (today only in connection with dynamic problems)

  3. 2010–2011

    Vibration measurements for the demolition of the Deutschlandhalle (lantern) with three DIN 45669-C15HV80/1 monitoring systems

  4. 2017–2018

    Vibration monitoring during the demolition of Budapester Straße 35, Berlin, with two monitoring systems and 30 sensors

  5. 2019

    Withdrawal of Bernhard Faust; continuation as a sole proprietorship under 'iff – Ingenieurbüro für Dynamik und Erschütterungen' by Dr.-Ing. Matthias Fritsche

Try it now

Test Amplifa Marketplace – no appointment needed.

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — sign up in minutes and start on your own.

Create your free account