Independent testing laboratory for standards-compliant photometric and spectral measurements on light sources and luminaires.

ILUmetriX GmbH
Meschede-HeinrichsthalNew on Amplifa
About ILUmetriX
ILUmetriX GmbH is an independent institute for applied lighting technology based in Meschede in the Sauerland region. Its core business is standards-compliant measurement of light sources and luminaires. Its range of services includes photometric measurements according to EN 13032 and IES LM-79-08, luminous flux measurements, the creation of 3D luminous intensity distributions (LVK, LDT/IES), temperature-dependent measurements on LED modules, flicker measurements and spectral measurements in the 200–3000 nm range. In addition, the company offers photobiological safety testing according to DIN EN 62471 using a double monochromator system, EMC measurements according to EN 55015, EN 61547 and EN 61000-3-2, as well as consulting on European directives, regulations and standards in lighting technology. Founded in 2008, the company set up a modern lighting laboratory with high-quality measurement equipment on a former weaving mill site, including a rotating-mirror goniophotometer with a 15 m measuring distance, integrating spheres (Ulbricht spheres) and a double monochromator IDR 300 PSL. Its customers are manufacturers of lamps, LED modules and luminaires from the lighting industry.
- Site
- Meschede
- Processes
- Photometric measurements according to EN 13032 / IES LM-79-08, Luminous flux measurements on lamps and luminaires, Creation of 3D luminous intensity distributions (LVK), formats LDT/IES; conversion of lighting, Temperature-dependent measurement of photometric and colorimetric parameters on LED modules, Flicker measurements (flicker frequency, flicker percentage, flicker index), Measurement of the spectral light distribution 380–800 nm; spectral measurements 200–3000 nm, Photobiological safety testing according to DIN EN 62471 (300-1400 nm, 200-1400 nm, 200-3000 nm), Measurement of photosynthetically active radiation 400-700 nm on plant lighting (PAR, PPF, PPFD)
- Materials
- LED modules, Lamps/Bulbs, Luminaires
- Certificates
- EN 13032 / IES LM-79-08, DIN EN 62471, EN 60598, EMC EN 55015 / EN 61547 / EN 61000-3-2, ISO 9001
- Founded
- 2008
- Industries
- Lighting technology, LED / luminaire manufacturers
- 01
Order / consulting on standards and directives
- 02
Sample intake in the laboratory
- 03
Photometric measurement (goniophotometer, integrating sphere)
- 04
Spectral measurement / photobiological safety testing
- 05
Evaluation and report (LDT/IES, LVK)
Test Objects & Test Methods
LED modules
Temperature-dependent photometric and colorimetric measurements on LED modules.
Lamps/Bulbs
Luminous flux and photometric measurements including energy efficiency classification.
Luminaires
Determination of gross/net luminous fluxes and luminous intensity distributions.
Locations

Meschede-Heinrichsthal
DELighting technology laboratory / Company headquarters
- Materials
- LED modules, lamps, luminaires
- Rotating-mirror goniophotometer (15 m measuring distance)
- Integrating sphere UL-1650/2250
- Double monochromator IDR 300 PSL
Services


Inside the production


Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Photometric measurements according to EN 13032 / IES LM-79-08Testing | – | – | – | – | – |
| Luminous flux measurements on lamps and luminairesTesting | – | – | – | – | – |
| Creation of 3D luminous intensity distributions (LVK), formats LDT/IES; conversion of lightingTesting | – | – | – | – | – |
| Temperature-dependent measurement of photometric and colorimetric parameters on LED modulesTesting | – | – | – | – | LED modules |
| Flicker measurements (flicker frequency, flicker percentage, flicker index)Testing | – | – | – | – | – |
| Measurement of the spectral light distribution 380–800 nm; spectral measurements 200–3000 nmTesting | – | – | – | – | – |
| Photobiological safety testing according to DIN EN 62471 (300-1400 nm, 200-1400 nm, 200-3000 nm)Testing | – | – | – | – | – |
| Measurement of photosynthetically active radiation 400-700 nm on plant lighting (PAR, PPF, PPFD)Testing | – | – | – | – | – |
| Irradiance and radiance measurementsTesting | – | – | – | – | – |
| Measurements according to EN 60598Testing | – | – | – | – | – |
| EMC measurements (EN 55015:2009, EN 61547:2000, EN 61000-3-2:2009)Testing | – | – | – | – | – |
| Consulting on directives, regulations and standards in lighting technologyEngineering | – | – | – | – | – |
3 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Goniophotometer (rotating mirror) | – | – | Far-field measurement over 15 m measuring distance | – | Meschede-Heinrichsthal |
| Integrating sphere (Ulbricht sphere) | UL-1650/2250 | – | – | – | Meschede-Heinrichsthal |
| Double monochromator system | IDR 300 PSL | – | – | – | Meschede-Heinrichsthal |
Additional services
Quality & Standards
Measurements are performed in accordance with EN 13032, IES LM-79-08, DIN EN 62471, EN 60598 as well as EMC standards such as EN 55015, EN 61547 and EN 61000-3-2.
| Evidence | Meschede-Heinrichsthal |
|---|---|
| EN 13032 / IES LM-79-08 | |
| DIN EN 62471 | |
| EN 60598 | |
| EMC EN 55015 / EN 61547 / EN 61000-3-2 | |
| ISO 9001 |
History
- 2008
Foundation of ILUmetriX GmbH; company headquarters in Meschede in the Sauerland on a former weaving mill site, converted into a modern lighting laboratory