
Planning, installation and maintenance of heat tracing, leak detection systems and infrared heating for industry and building services

K&T Begleitheizungsgesellschaft GmbH
Hofheim am Taunus (Headquarters)New on Amplifa
About K&T Begleitheizungsgesellschaft
K&T Begleitheizungsgesellschaft GmbH is a system provider for industrial heat and safety systems based in Hofheim am Taunus. The company plans, installs and maintains electric heat tracing for pipes, tanks, vessels and special constructions – from thermal calculation and design through standards-compliant installation by qualified electricians to DGUV-compliant documentation. A second pillar is sensor-based leak detection systems with point, line and cable sensors, which are integrated into existing PLC, BMS and building management systems via Modbus, BACnet or OPC UA. The portfolio is complemented by infrared heaters for residential, office and commercial spaces as well as halls. Customers come from the chemical, petrochemical, energy and utility sectors, data centers, food and pharma, mechanical engineering, and infrastructure and building services. As an nVent Raychem system partner, the company uses heating cables in compliance with standards and offers around-the-clock emergency support. Founded in 2019, the company combines over 20 years of industry experience of its managing director with certified, operational personnel according to SCC Document 017.
- Site
- Hofheim am Taunus
- Processes
- Electric heat tracing (frost protection & temperature maintenance), Heat tracing for pipework, Tank and silo heating, Heat tracing in Ex areas (ATEX), Heat tracing for gas pressure regulating and metering stations, Heat tracing for district heating transfer stations, Frost protection for sprinkler and fire-fighting water lines, Frost protection for roof gutter and drainage systems
- Materials
- Water, Oil, Acids, Alkalis, Coolant, Chocolate, Fats, Syrups
- Certificates
- SCC (Safety Certificate for Contractors, SCC Document 017), nVent Raychem system partner / heating cable installation training, SCC Document 017, nVent Raychem system partner / installation training, DGUV-compliant function testing, Scaffolding inspection according to BG-BAU guidelines, VDE / IEC 60529
- Founded
- 2019
- Industries
- Chemical & Petrochemical, Energy & Utilities, Data Centers & Building Services, Food & Pharma, Industry & Mechanical Engineering, Infrastructure & Construction
- 01
Consultation and inquiry review
- 02
Thermal calculation and design
- 03
Risk analysis and sensor selection
- 04
Planning of system and wiring diagrams
- 05
Standards-compliant installation and assembly
- 06
Integration into PLC/BMS/building management systems
- 07
Function testing, calibration, acceptance
- 08
Documentation and annual maintenance
- 09
24/7 emergency support
Media and System Technology
Leak sensors for water
Point, line and cable sensor technology for early detection of water leaks, e.g. in raised floors of data centers.
Leak sensors for oil and coolant
Sensor-specific design for oil, coolant and process media in industrial plants.
Leak sensors for acids and alkalis
Material-resistant sensor technology for aggressive media in chemical and process plants.
nVent Raychem heating cables
Self-regulating heating cables for frost protection and temperature maintenance, installed in compliance with standards as a system partner.
Infrared heating
Radiant heat for workstations, halls and outdoor areas without air circulation.
Locations

Hofheim am Taunus
DEHeadquarters, planning and sales
- Materials
- Heating cables, sensor technology, infrared heating
- Point and line sensor technology
- Cable sensor technology
- nVent Raychem heating cables
- Intelligent evaluation units (Modbus RTU/TCP, BACnet, OPC UA)
Systems and Applications



Inside the production



Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Electric heat tracing (frost protection & temperature maintenance)Installation | – | – | – | – | – |
| Heat tracing for pipeworkInstallation | – | – | – | – | Water, viscous media, chemical media, chocolate, fats, syrups |
| Tank and silo heatingInstallation | – | – | – | – | – |
| Heat tracing in Ex areas (ATEX)Installation | – | – | – | – | – |
| Heat tracing for gas pressure regulating and metering stationsInstallation | – | – | – | – | – |
| Heat tracing for district heating transfer stationsInstallation | – | – | – | – | – |
| Frost protection for sprinkler and fire-fighting water linesInstallation | – | – | – | – | Water |
| Frost protection for roof gutter and drainage systemsInstallation | – | – | – | – | Water |
| Frost protection for parking garages and rampsInstallation | – | – | – | – | – |
| Heating of safety showers (ANSI Z358.1)Installation | – | – | – | – | Water |
| Heating of dosing and filling systems, extruders and special valvesInstallation | – | – | – | – | – |
| Leak detection systems (point, line and cable sensor technology)Testing | Localization ±1 m | – | – | – | Water, oil, acids, alkalis, coolant |
| Early leak detection in raised floors & cable ducts (data centers)Testing | – | – | – | – | Water |
| Integration of leak sensors into PLC/BMS/building management systems (Modbus RTU/TCP, BACnet, OPCEngineering | – | – | – | – | – |
| Automatic valve control & pump shutdown on leak alarmEngineering | Response time < 5 seconds | – | – | – | – |
| Infrared heating (radiant heat for rooms, halls & outdoor areas)Installation | – | – | – | – | – |
| Thermal calculation & design of heating cable typesEngineering | – | – | – | – | – |
| DIN-compliant installation by qualified electriciansInstallation | – | – | – | – | – |
| Scaffolding inspection according to BG-BAU guidelinesTesting | – | – | – | – | – |
| DGUV-compliant function testing, maintenance & calibrationTesting | – | – | – | – | – |
5 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Point sensor technology | – | – | – | – | – |
| Line sensor technology | – | – | – | – | – |
| Cable sensor technology | – | – | – | – | – |
| Heating cables | nVent Raychem | – | – | – | – |
| Intelligent evaluation units | – | – | – | – | – |
Additional services
Reference customers
Quality and Safety
Installation is carried out in compliance with DIN and VDE standards by qualified electricians with SCC-certified operational personnel (SCC Document 017). Testing and documentation follow DGUV requirements, including test reports, as-built documentation, annual maintenance and calibration.
| Evidence | Hofheim am Taunus |
|---|---|
| SCC Document 017 | |
| nVent Raychem system partner / installation training | |
| DGUV-compliant function testing | |
| Scaffolding inspection according to BG-BAU guidelines | |
| VDE / IEC 60529 |
Company History
- 2019
Founding of K&T Begleitheizungsgesellschaft GmbH
The managing director has more than 20 years of experience in the heat tracing industry