Designs and installs security technology: fire alarm, intrusion detection, alerting and video surveillance systems.

KHL Elektroanlagen GmbH
Taufkirchen (headquarters)New on Amplifa
About KHL Elektroanlagen
KHL Elektroanlagen GmbH is an electrical company specialised in security technology, headquartered in Taufkirchen near Munich. The company designs and installs customised security systems for private, public and commercial buildings and facilities. Its service portfolio covers fire alarm systems according to DIN 14675, electroacoustic alerting and voice alarm systems, intrusion and hold-up alarm systems, video surveillance systems, access control systems, fire protection and emergency exit door controls according to DIN EN 13637, as well as smoke and heat extraction systems according to DIN 18232. In addition, perimeter security systems, remote control technology and VPN connections are implemented. Alongside consulting, planning and installation, KHL provides standard-compliant maintenance and servicing of the systems, including smoke detector replacement according to DIN 14675, as well as a 24-hour on-call service. For electroacoustic alerting systems – from small compact systems to large public address systems for sports venues and industrial facilities – the company works with the partners Dynacord and Hekatron. Target industries include, among others, schools, sports venues and department stores.
- Site
- Taufkirchen
- Processes
- Security technology – design and installation of customised security systems, Fire protection technology / fire alarm systems (fire alarm control panel, fire scenario control), Intrusion detection systems / intrusion and hold-up alarm systems, Video surveillance / video systems, Electroacoustic alerting systems (compact systems up to large public address systems), Voice alarm systems / voice alarm (VdS recognition as installer according to DIN 14675), Standard-compliant maintenance and servicing of hazard detection systems incl. smoke detector, Fire protection/emergency exit door controls according to DIN EN 13637
- Materials
- Fire alarm systems, Voice alarm systems, Intrusion and hold-up alarm systems, Video surveillance systems, Access control systems, Smoke and heat extraction systems
- Certificates
- VdS recognition as installer of voice alarm systems DIN 14675, DIN 14675 (VdS recognition for voice alarm systems), VDE 0833, DIN EN 62676 Part 4, DIN EN 60839, DIN EN 13637, DIN 18232
- Industries
- Private buildings, Public buildings, Commercial buildings and facilities, Schools, Sports venues, Department stores
- 01
Consulting and requirements analysis
- 02
Planning and detailed design
- 03
Quotation and specification of services
- 04
Assembly and installation
- 05
Programming and commissioning
- 06
Standard-compliant maintenance and servicing
Systems and Technologies
Fire alarm systems
Fire alarm control panel with fire scenario control according to DIN 14675 and VDE 0833 Part 1 and 2 as the core of system-based fire protection.
Voice alarm systems
Electroacoustic alerting and voice alarm systems according to DIN VDE 0833 Part 4, coupled solutions linked to fire detection.
Intrusion and hold-up alarm systems
Hazard detection systems according to DIN VDE 0833 Part 3 for the protection of buildings and property.
Video surveillance systems
Video systems according to DIN EN 62676 Part 4 / VDE 0830-71 Part 4 for commercial and public buildings.
Access control systems
Access systems according to DIN EN 60839 and DIN VDE 0830 including fire protection/emergency exit door controls according to DIN EN 13637.
Smoke and heat extraction systems
System-based fire protection according to DIN 18232.
Locations
Taufkirchen
DEHeadquarters, planning and installation
- Materials
- Fire alarm, voice alarm, intrusion detection, video, access control and smoke and heat extraction systems
Systems





Inside the production



Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Security technology – design and installation of customised security systemsEngineering | – | – | – | – | – |
| Fire protection technology / fire alarm systems (fire alarm control panel, fire scenario control)Assembly | – | – | – | – | – |
| Intrusion detection systems / intrusion and hold-up alarm systemsAssembly | – | – | – | – | – |
| Video surveillance / video systemsAssembly | – | – | – | – | – |
| Electroacoustic alerting systems (compact systems up to large public address systems)Assembly | – | – | – | – | – |
| Voice alarm systems / voice alarm (VdS recognition as installer according to DIN 14675)Assembly | – | – | – | – | – |
| Standard-compliant maintenance and servicing of hazard detection systems incl. smoke detectorAssembly | – | – | – | – | – |
| Fire protection/emergency exit door controls according to DIN EN 13637Assembly | – | – | – | – | – |
| Smoke and heat extraction systems (system-based fire protection) according to DIN 18232Assembly | – | – | – | – | – |
| Perimeter security systemsAssembly | – | – | – | – | – |
| Access control systems according to DIN EN 60839 and DIN VDE 0830Assembly | – | – | – | – | – |
| Repair and restoration of hazard detection and security technology systemsAssembly | – | – | – | – | – |
| Programming and commissioning of hazard detection systemsAssembly | – | – | – | – | – |
Additional services
Quality and Standards
KHL is recognised by VdS as an installer of voice alarm systems according to DIN 14675 and implements hazard detection systems in accordance with the relevant DIN and VDE standards. Standard-compliant maintenance and servicing is supplemented by trained personnel and a 24-hour on-call service.
| Evidence | Taufkirchen |
|---|---|
| DIN 14675 (VdS recognition for voice alarm systems) | |
| VDE 0833 | |
| DIN EN 62676 Part 4 | |
| DIN EN 60839 | |
| DIN EN 13637 | |
| DIN 18232 |