PhysChem Analytics GmbH, based in Feucht near Nuremberg, is a service company for physical-chemical materials analysis. The laboratory characterizes plastics, lubricants, (cosmetic) emulsions, suspensions, adhesives, resins as well as paints and coatings with regard to purity, composition, additive and filler content and physical properties. The range includes FT-IR and UV/Vis spectroscopy, thermal analysis (DSC, TG, DMTA), rheology, tensiometry, gas chromatography (pyrolysis GC-MS, FID/WLD), dispersion and stability analysis, microscopy as well as density, refractometry, calorimetry and BET measurements. Typical applications are material characterization, failure analysis, batch and incoming goods inspections, storage tests, process optimization as well as contract research and product development, complemented by customized seminars. To this end, the company cooperates with universities and research institutions and carries out all measurements in accordance with recognized rules of technology.
- Site
- Feucht
- Processes
- FT-IR spectroscopy (identification of foreign substances/contaminants, IR mapping, ATR), Thermal analysis (DSC, TG, DMTA), Rheology (flow curves, viscoelasticity, torsion measurements, tribology, curing behavior), Material characterization – identification and composition, Failure analysis (trace analysis, contamination, thermal/mechanical damage), Quality control (batch and incoming goods inspections, storage tests), Process optimization, Contract research and product development
- Materials
- Plastics, Lubricants, (Cosmetic) emulsions, Suspensions, Adhesives, Resins, Paints, Coatings
- Certificates
- Recognized rules of technology
- Industries
- Plastics, Lubricants, Cosmetics (emulsions), Adhesives, Resins, Paints and Coatings
- 01
Inquiry and consultation on analysis methods
- 02
Sample receipt
- 03
Material characterization with spectroscopy, thermal analysis, rheology etc.
- 04
Evaluation and failure analysis
- 05
Report and process optimization
- 06
Quality control/seminars as follow-up services
Materials and Analysis Methods
Plastics
Characterization by means of thermal analysis, DMTA, FT-IR and Shore hardness/impact strength tests.
Lubricants
Determination of viscosity, density and thermal properties.
Emulsions (cosmetic)
Stability and rheological investigations including rock tests.
Suspensions
Dispersion and segregation analysis with an analytical centrifuge.
Adhesives
Curing behavior and contaminant identification.
Resins (epoxy, phenol/formaldehyde)
Rheological reactivity and curing measurements incl. UV curing.
Paints and Coatings
Identification of components and physical-chemical properties.
FT-IR Spectroscopy
Identification of foreign substances, IR mapping and ATR including microscopy of small samples.
Thermal Analysis (DSC, TG, DMTA)
Melting point, glass transition, thermal stability and crosslinking behavior.
Rheology
Flow curves, viscoelasticity, tribology and curing behavior on melts, emulsions and GRP.
Tensiometry
Contact angle, surface energy and bubble pressure measurement.
Pyrolysis GC-MS / GC (FID, WLD)
Quantification and composition analysis.
Locations
Feucht
DEHeadquarters and analytics laboratory
- Materials
- Plastics, lubricants, emulsions, suspensions, adhesives, resins, paints/coatings
Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| FT-IR spectroscopy (identification of foreign substances/contaminants, IR mapping, ATR)Testing | – | – | – | – | Plastics, Lubricants, Emulsions, Suspensions, Adhesives, Resins, Paints, Coatings |
| Thermal analysis (DSC, TG, DMTA)Testing | – | – | – | – | Plastics, Polymers |
| Rheology (flow curves, viscoelasticity, torsion measurements, tribology, curing behavior)Testing | – | – | – | – | Polymer melts, Emulsions, Suspensions, Epoxy resins, Phenol/formaldehyde resins, GRP |
| Material characterization – identification and compositionTesting | – | – | – | – | Plastics, Lubricants, Cosmetic emulsions, Suspensions, Adhesives, Resins, Paints, Coatings |
| Failure analysis (trace analysis, contamination, thermal/mechanical damage)Testing | – | – | – | – | – |
| Quality control (batch and incoming goods inspections, storage tests)Testing | – | – | – | – | – |
| Process optimizationEngineering | – | – | – | – | – |
| Contract research and product developmentEngineering | – | – | – | – | – |
| Tensiometry (contact angle, surface energy, bubble pressure)Testing | – | – | – | – | – |
| UV/Vis and fluorescence spectroscopyTesting | – | – | – | – | – |
| Pyrolysis GC/MS and GC (FID/WLD)Testing | – | – | – | – | – |
| Dispersion and stability analysis (analytical centrifuge, 4–60 °C)Testing | – | – | – | – | – |
| Plastics characterization (DMTA, Shore hardness A/D, impact strength)Testing | – | – | – | – | Plastics |
| Viscosimetry (kinematic and dynamic viscosity)Testing | – | – | – | – | – |
| Density measurement, refractometry, boiling diagrams, combustion calorimetry, BET adsorptionTesting | – | – | – | – | – |
| Microscopy (digital microscope 100x–1000x, incident/transmitted light)Testing | – | – | – | – | – |
| Seminars/training (rheology, thermal analysis, FT-IR, physical-chemical parameters)Engineering | – | – | – | – | – |
29 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| FT-IR spectrometer | Thermo Scientific Nicolet 6700 | 1 | – | – | Feucht |
| FT-IR microscope | Thermo Scientific Nicolet iN 10 MX | 1 | – | – | Feucht |
| Digital microscope (100x–1000x, incident/transmitted light) | Keyence VHX-1000 | 1 | – | – | Feucht |
| UV/Vis spectrometer with temperature-controlled sample changer | Varian Cary 100 | 1 | – | – | Feucht |
| Fluorescence spectrometer with temperature-controlled sample changer | Varian Cary Eclipse | 1 | – | – | Feucht |
| Dispersion analyzer (analytical centrifuge), 4–60 °C | LUM Limisizer (Lumisizer) | 1 | – | – | Feucht |
| Pyrolysis gas chromatograph with mass spectrometer | Shimadzu QP5050 | 1 | – | – | Feucht |
| Gas chromatograph with FID and WLD | Shimadzu GC2010 Plus | 1 | – | – | Feucht |
| DSC with liquid nitrogen cooling, –150 to 600 °C | Netzsch F1 Phoenix | 1 | – | – | Feucht |
| DSC with sample changer, –80 to 600 °C | Netzsch F1 Phoenix | 1 | – | – | Feucht |
| DSC, RT–550 °C | Mettler Toledo DSC 30 | 1 | – | – | Feucht |
| Thermobalance (TG), 0–1000 °C | Netzsch F1 Iris TG | 1 | – | – | Feucht |
| Thermobalance (TG), RT–1000 °C | Mettler Toledo TG 50 | 1 | – | – | Feucht |
| Viscometer | Lauda DC 15 | 1 | – | – | Feucht |
| Fully automatic viscometer | Herzog HVM 482 | 1 | – | – | Feucht |
| Rheometer (with Peltier and electric temperature chamber, DMTA, UV, tribology accessories) | Anton Paar MCR 301 | 1 | – | – | Feucht |
| Rheometer with second motor (counter-rotating/co-rotating), –40 to 400 °C per measuring system | Anton Paar MCR 702 | 1 | – | – | Feucht |
| Bubble pressure tensiometer | Krüss BP2100 Pocket Dyne | 1 | – | – | Feucht |
| Tensiometer (ring and plate), –10 to 80 °C | Krüss K100C | 1 | – | – | Feucht |
| Drop Shape Analyzer (contact angle, surface energy) | Krüss DSA 30 | 1 | – | – | Feucht |
| Programmable heating oven, RT–250 °C | – | – | – | – | Feucht |
| Vacuum drying oven, RT–250 °C, vacuum down to 0.1 mbar | – | – | – | – | Feucht |
| Climate chamber (temperature/humidity) | – | – | – | – | Feucht |
| Density meter, 10–90 °C | Anton Paar DMA 4500 | 1 | – | – | Feucht |
| Refractometer, 10–70 °C | Anton Paar Abbemat WR | 1 | – | – | Feucht |
| Automatic boiling apparatus (boiling diagrams) | – | – | – | – | Feucht |
| Combustion calorimeter | IKA C200 | 1 | – | – | Feucht |
| Adsorption apparatus BET method | – | – | – | – | Feucht |
| Apparatus for gas solubility and vapor pressure measurement | – | – | – | – | Feucht |
Additional services
Quality
The measurements are carried out according to recognized rules of technology and methods performed at the state of the art; the equipment includes calibrated measuring systems from Thermo Scientific, Netzsch, Anton Paar, Krüss and other manufacturers.
| Evidence | Feucht |
|---|---|
| Recognized rules of technology |