Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
Pro Aqua Aeria – Fertigung

Services for water damage, leak detection, building drying and measurement technology in the Augsburg-Munich region.

Pro Aqua Aeria Logo

Pro Aqua Aeria GmbH & Co. KG

Dasing · Dasing (warehouse and office)New on Amplifa

1998Founded
GmbH & Co. KGLegal form
Augsburg-Munich regionOperating area

About us

Pro Aqua Aeria is a family-owned, owner-managed company founded in 1998, headquartered in Dasing in the district of Aichach-Friedberg and operating in the Augsburg-Munich region. Its service portfolio includes leak detection in supply and wastewater systems, water damage remediation including insurance handling, technical building drying, construction and hall heating, mobile construction dust extraction, and measurement-based diagnostics such as moisture measurement, blower-door testing in accordance with DIN EN 13829, thermography and mould analysis. In addition, the company offers odour neutralisation, air purification with class H13 HEPA filters, room humidification, and an equipment rental fleet with sales. The company relies on a modern, sound-insulated and energy-efficient machine fleet; managing director Dipl.-Ing. Markus Schadl is a certified air-tightness tester under ISO 20807 and a Level 1 thermographer under ISO 9712.

Site
Dasing
Processes
Water damage remediation and leak detection, Drying of affected rooms, ceilings, walls and screed insulation layer (room drying,, Leak detection (pressure test, acoustic detection/listening device, tracer gas detection, pipe, Technical building drying (dehumidification), Construction and hall heating (electric construction heating, 3.3 to 15 kW, 230 V and 400 V), Mobile construction dust extraction, CM measurement of screed, Air-tightness testing of buildings (blower-door test) in accordance with DIN EN 13829 (pressure
Certificates
Certified air-tightness tester (ISO 20807), Thermographer Level 1 (ISO 9712)
Founded
1998
Industries
Construction/Renovation, Remediation, Real estate/Property management, Museum/Historical monument/Church
  1. 01

    Damage analysis and documentation

  2. 02

    Leak detection

  3. 03

    Drying and remediation

  4. 04

    Measurement and report

  5. 05

    Insurance handling

Locations

Standort Dasing, Alpenstraße 7

Dasing, Alpenstraße 7

DE

Headquarters and office

  • Building dryers (up to 82 l/day)
  • Electric construction and heating units (3.3–15 kW)
  • Infrared heating plates and STIR radiant heaters
  • Pipe inspection camera
  • Acoustic listening device
  • Tracer gas detection equipment
  • Thermal imaging camera
  • Blower door measuring device
  • HEPA air purifiers (H13)

Dasing, Taitinger Str. 62

DE

Warehouse and office

Services

Building drying of a large construction site
Building drying of a large construction siteTechnical building drying · Construction
Ceiling and wall drying after water damage
Ceiling and wall drying after water damageWater damage remediation · Renovation
Blower-door test
Blower-door testAir-tightness testing · New building

Inside the production

Electric construction heating
Electric construction heating
Measurement technology diagnostics
Measurement technology diagnostics
Freshly laid screed before drying
Freshly laid screed before drying

Industries

Construction/RenovationRemediationReal estate/Property managementMuseum/Historical monument/Church

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Water damage remediation and leak detectionTesting–––––
Drying of affected rooms, ceilings, walls and screed insulation layer (room drying,Other–––––
Leak detection (pressure test, acoustic detection/listening device, tracer gas detection, pipeTesting–––––
Technical building drying (dehumidification)Other–––––
Construction and hall heating (electric construction heating, 3.3 to 15 kW, 230 V and 400 V)Other–––––
Mobile construction dust extractionOther–––––
CM measurement of screedTesting–––––
Air-tightness testing of buildings (blower-door test) in accordance with DIN EN 13829 (pressureTesting–––––
Building moisture measurement (non-destructive up to 30 cm depth)Testing–––––
Building and system thermography (thermal imaging, thermal bridges, dew point analysis,Testing–––––
Climate/room humidity (instantaneous and long-term measurement with data loggers)Testing–––––
Mould analysis (imprint samples, material samples)Testing–––––
Odour neutralisation (fogging device/spray mist, ozone generator)Other–––––
Air purification (HEPA filter class H13, separation efficiency 99.95 %)Other–––––
Humidification of rooms (humidifiers, e.g. museum/historical monument/church)Other–––––
Equipment rental fleet & sales: dehumidifiers/humidifiers/party heaters/air purifiersOther–––––

14 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Building dryers (dehumidification capacity up to 82 litres/day)––––Dasing
Electric construction/hall heating units (230 V and 400 V, 3.3 to 15 kW)––––Dasing
Infrared heating plates (max. 90 °C) and STIR radiant heaters (100–250 °C) for ceiling & wall drying––––Dasing
Pipe inspection camera with 20 m cable and locator transmitter in the camera head––––Dasing
Endoscope––––Dasing
Acoustic listening device (acoustic detection)––––Dasing
Tracer gas detection equipment––––Dasing
Thermal imaging camera––––Dasing
Blower door measuring device––––Dasing
Data loggers for indoor climate––––Dasing
Fogging device (spray mist) and ozone generator––––Dasing
HEPA air purifiers (filter class H13)––––Dasing
Mobile construction dust extractors––––Dasing
Anemometer and fog generator (leak search with blower door)––––Dasing

Additional services

Leak detectionWater damage remediation/room dryingScreed insulation layer dryingCeiling and wall dryingTechnical building drying (dehumidification)Construction and hall heatingMobile construction dust extractionCM measurement of screedBlower-door test (air-tightness testing in accordance with DIN EN 13829)Building moisture measurementBuilding and system thermographyClimate/room humidity measurement (instantaneous and long-term)Mould analysisOdour neutralisationAir purification (HEPA filters)Humidification of roomsEquipment rental fleet & sales (dehumidifiers/air purifiers/party heaters)Damage analysis/documentationInsurance handling

Quality

Measurements are documented; damage reports with photo documentation are prepared for property management and insurance companies. Qualified certifications of the management (ISO 20807, ISO 9712) ensure the proper conduct of testing.

EvidenceDasing
Certified air-tightness tester (ISO 20807)
Thermographer Level 1 (ISO 9712)

History

  1. 1998

    Founded as an owner-managed family business with services related to buildings

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo