Engineering services for structural plan review, structural diagnostics and structural design in civil and structural engineering

Prof. Stempniewski Beratende Ingenieure PartmbB
Stockach · EttlingenNew on Amplifa
About the engineering office
The engineering office, based in Stockach, has been active in the field of structural engineering since 1996. Its range of services includes structural plan reviews in building construction, industrial construction and bridge construction, structural diagnostics including building monitoring, building fabric analyses, including on historic buildings, as well as expert opinions on building damage and structural dynamics. The core business is structural design and consulting for structures made of reinforced and prestressed concrete, steel, timber, glass and plastics, including fire design (hot-state design) of reinforced concrete columns in accordance with Eurocode 2. For structural diagnostics, methods such as rebar location, load tests, vibration and oscillation measurements and non-destructive material testing are employed. Structural analysis software packages from Dlubal, Sofistik, Friedrich+Lochner and PCAE are used; dynamic load cases are analysed using frequency analysis or time-history calculations. A second office is located in Ettlingen.
- Site
- Stockach
- Processes
- Structural plan reviews (building construction, industrial construction, bridge construction), Structural diagnostics with building monitoring, Rebar location (rebar detector), Bridge investigations, Vibration measurements, Investigation of external tendons, Long-term monitoring, Load tests
- Materials
- Reinforced concrete, Prestressed concrete, Steel, Timber, Glass, Plastics, Reinforced and prestressed concrete, Steel construction
- Certificates
- ISO 9001
- Founded
- 1996
- Industries
- Building construction, Industrial construction, Bridge construction, Preservation of historical monuments, Historic buildings / heritage conservation
- 01
Consulting and project support
- 02
Structural design and structural analysis
- 03
Structural plan review
- 04
Structural diagnostics and monitoring
- 05
Expert reports and expert witness services
Construction methods and software
Reinforced and prestressed concrete
Core business in structural design and review, including fire design of reinforced concrete columns in accordance with Eurocode 2.
Steel construction
Design and structural plan review of steel structures.
Timber construction
Structural design and consulting for timber structures.
Glass
Structural design of glass structures.
Plastics
Structural design of plastic structures.
Locations

Stockach
DEHead office
- Materials
- Reinforced/prestressed concrete, steel, timber, glass, plastics
- Hilti PS 200 Ferroscan
- Dlubal
- Sofistik
- Friedrich+Lochner
- PCAE
Ettlingen
DEOffice
Services



Inside the production


Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Structural plan reviews (building construction, industrial construction, bridge construction)Testing | – | – | – | – | reinforced concrete, prestressed concrete, steel, timber, glass, plastics |
| Structural diagnostics with building monitoringTesting | – | – | – | – | – |
| Rebar location (rebar detector)Testing | – | – | – | – | reinforced concrete |
| Bridge investigationsTesting | – | – | – | – | – |
| Vibration measurementsTesting | – | – | – | – | – |
| Investigation of external tendonsTesting | – | – | – | – | prestressed concrete |
| Long-term monitoringTesting | – | – | – | – | – |
| Load testsTesting | – | – | – | – | – |
| Vibration and oscillation investigationsTesting | – | – | – | – | – |
| Non-destructive material testingTesting | – | – | – | – | – |
| Building fabric analysis / existing building analysis (including historic buildings)Testing | – | – | – | – | – |
| Expert opinions (building damage, structural dynamics)Testing | – | – | – | – | – |
| Structural design in civil and structural engineering (structural analysis, fire design ofEngineering | – | – | – | – | reinforced concrete, prestressed concrete, steel, timber, glass, plastics |
5 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Rebar detector (Ferroscan) | Hilti PS 200 Ferroscan System | – | – | – | Stockach |
| Structural analysis software (software package) | Dlubal | – | – | – | – |
| Structural analysis software (software package) | Sofistik | – | – | – | – |
| Structural analysis software (software package) | Friedrich+Lochner | – | – | – | – |
| Structural analysis software (software package) | PCAE | – | – | – | – |
Additional services
Quality and competence
The engineers receive continuous further training through internal and external training courses. In structural diagnostics, the office works closely with the Institute of Concrete Structures and Building Materials at KIT, the MPA Karlsruhe and local testing institutes.
| Evidence | Stockach |
|---|---|
| ISO 9001 |
History
- 1996
Foundation of the office by Dipl.-Ing. C. Hofmann in Stockach, Ziegelwiese 33
- 2011
Relocation to Goethestraße 33 in Stockach
- 2017
Establishment of Prof. Stempniewski Beratende Ingenieure PartmbB with the partners Prof. Stempniewski and Mr Hauser