SCHICO manufactures the M2000 microbe sampler for detecting microorganisms in compressed gases as well as sterile small apparatuses for medical-pharmaceutical applications.

SCHICO Ingenieurbüro für chemische, pharmazeutische und biomedizinische Anlagen und Verfahren GmbH
Ruffinistrasse 8, 80637 MünchenNew on Amplifa
About SCHICO
SCHICO Ing.-Büro GmbH was founded in Munich in 1976 and specializes in sterile apparatus engineering for chemical, pharmaceutical and biomedical applications. Its core product is the in-house developed M2000 microbe sampler, a portable measuring system for detecting microorganisms in compressed gases using the membrane filter method in accordance with ISO 14698, whose manufacture, distribution and annual aftercare (calibration and function test) are carried out by the company. Another in-house development is the M2000DUO, which fills two different medical gases into a syringe with high precision and sterility. Previously, SCHICO developed the ZYCLODEST thermal water distillation systems and the ZYCLODAMPF pure steam generators; around 100 systems of this type were delivered worldwide, but the plant business was divested. Today, the company works in small-scale apparatus construction for medical-pharmaceutical purposes at its Munich location.
- Site
- München
- Processes
- Small-scale apparatus construction for medical-pharmaceutical purposes (manufacture of the M2000, Calibration and function test (annual aftercare of the M2000 microbe sampler), Development of sterile apparatus engineering and processes (ZYCLODEST thermal water distillation,, Sterile filling of medical gases (M2000DUO: two medical gases filled sterile into one syringe), Manufacture, distribution and annual aftercare (calibration and function test) of the microbe, Development and distribution of medical-pharmaceutical small apparatuses, Development of thermal water distillation systems (ZYCLODEST) and pure steam generators (ZYCLODAMPF)
- Materials
- M2000 Microbe Sampler, M2000DUO Microbe Sampler, Thermal Water Distillation System, Pure Steam Generator, Autoclavable Part, Pall-Gelmann Type, Membrane Filter Method
- Founded
- 1976
- Industries
- Pharmaceutical industry, Chemical industry, Biomedical/Medical technology, Cleanroom technology
- 01
Development and design
- 02
Manufacturing in small-scale apparatus construction
- 03
Assembly and distribution
- 04
Annual aftercare: calibration and function test
Developments and Products
M2000 Microbe Sampler
Portable measuring system for detecting microorganisms in compressed gases using the membrane filter method, in accordance with ISO 14698, with German Patent No. 198 12 551.
M2000DUO Microbe Sampler
Fills two different medical gases, e.g. oxygen and carbon dioxide, into a syringe with high precision and sterility.
Thermal Water Distillation System
Distillation system with a second circuit, separate from the distillate, for the heat pump compressor.
Pure Steam Generator
In-house development for pure steam generation for pharmaceutical applications.
Autoclavable Part, Pall-Gelmann Type
Accessory part for holding the membrane filter, sterilized in the autoclave at 121 °C for 20 minutes before each measurement.
Membrane Filter Method
Gas testing at the pressure at which the gas is used in production; slow pressure release protects the cell membranes.
Location

Munich
DEHeadquarters, manufacturing, distribution and aftercare
- M2000 Microbe Sampler
- M2000DUO Microbe Sampler
Components and Accessories


Inside the production



Industries
Processes & technical limits
| Processes | Tolerance | Max. part | Weight | Lot size | Materials |
|---|---|---|---|---|---|
| Small-scale apparatus construction for medical-pharmaceutical purposes (manufacture of the M2000Assembly | – | – | – | – | – |
| Calibration and function test (annual aftercare of the M2000 microbe sampler)Testing | – | – | – | – | – |
| Development of sterile apparatus engineering and processes (ZYCLODEST thermal water distillation,Engineering | – | – | – | – | – |
| Sterile filling of medical gases (M2000DUO: two medical gases filled sterile into one syringe)Testing | high precision (not quantified) | – | – | – | – |
2 Anlagen & Maschinen
| Machine | Manufacturer / model | Quantity | Working area | Year built | Site |
|---|---|---|---|---|---|
| Microbe sampler M2000 (measuring system for detecting microorganisms in compressed gases, membrane | SCHICO M2000 | – | – | – | Munich |
| Microbe sampler M2000DUO (sterile filling of two medical gases) | SCHICO M2000DUO | – | – | – | Munich |
Additional services
Reference customers
History
- 1976
Founding of SCHICO Ing.-Büro GmbH, Munich
- 2008
SCHICO microbe sampler M2000, specially designed for detecting microorganisms in compressed gases, German Patent No. 198 12 551 granted
- 2012
New accessories for the SCHICO microbe sampler M2000 presented
- 2016
M2000 as a proven measuring system for detecting microorganisms in compressed gases in accordance with ISO 14698
- 2020
Technical article on the collection of vegetative microorganisms in gases
- 2024
SEEKING SUCCESSOR: Search for a successful successor for the small company
Divestment of the plant business (ZYCLODEST/ZYCLODAMPF, around 100 systems delivered worldwide); today active in small-scale apparatus construction for medical-pharmaceutical purposes