Skip to content
NEW: CREATE AN AI-ASSISTED TENDER IN 2 MINUTES — TRY IT FREE
Back to search
Lütronic – Fertigung

Sound measurements, sound reports, sound level limiters and media systems for events and venues.

Lütronic Logo

Lütronic Elektroakustik GmbH

13403 Berlin (Grosskopfstraße 6-7)New on Amplifa

HRB 20927 B, Amtsgericht BerlinCommercial register entry
BerlinLocation
40+ yearsExperience in level calibration and noise limitation
20+ yearsExperience in the design and planning of electroacoustic

About Lütronic Elektroakustik

Lütronic Elektroakustik GmbH, based in Berlin, specialises in sound measurements, noise limitation and the design of electroacoustic systems. With more than 40 years of experience in level calibration and noise limitation of sound systems, the company is one of the first specialised providers in Germany. Its service portfolio includes sound reports and measurement reports for authorities, sound measurements accompanying events, as well as forecasts and consulting on stage and loudspeaker positioning. For over 20 years, the team has also planned and implemented sound, lighting and conference systems for event venues, including acoustic room optimisation, streaming solutions and central site-wide sound distribution via its own 100 V network. In-house electronics development for industrial, medical and control technology complements the portfolio, including the latency-free sound level limiter SPB 422 with simultaneous dB(A) and dB(C) weighting in accordance with DIN EN 61672-1. Reference clients range from clubs such as Berghain and festivals such as the Berlinale to major events such as the Berlin Marathon.

Site
Berlin
Processes
Hardware and software development for industrial, medical and control technology, Sound level limiter SPB 422 (in-house development, analogue signal path, latency-free), Sound measurements, level calibration, sound reports and measurement reports, Planning, implementation and installation of sound, lighting, conference and sound systems, Sound measurements and noise measurements, Sound reports and measurement reports, Level calibration of sound systems, Integration of sound level limiters
Materials
Sound level limiter SPB 422, Connection system LC 100, FlexTester, CCS
Certificates
DIN EN 61672-1 (frequency weighting SPB 422)
Industries
Event technology, Catering/Clubs and bars, Festivals and major events, Sporting events, Medical technology, Energy infrastructure
  1. 01

    Sound forecasts and consulting on stage/loudspeaker positioning

  2. 02

    Sound measurements and sound reports

  3. 03

    Level calibration of sound systems

  4. 04

    Integration of sound level limiters (in-house development SPB 422)

  5. 05

    Planning and implementation of sound, lighting and conference systems

  6. 06

    Maintenance and event-accompanying measurements

Development & Standards Compliance

SPB 422

Sound level limiter SPB 422

In-house developed limiter with a fully analogue, latency-free signal path (<0.0005 ms) and simultaneous A-weighted and C-weighted evaluation in accordance with DIN EN 61672-1.

LC 100

Connection system LC 100

In-house development for connecting the sound systems of individual showmen to the central site-wide sound distribution via a 100 V network.

FlexTester

FlexTester

System for long-term stress testing in medical technology.

CCS

CCS

System for cleaning documentation in the medical field.

Location

Standort Berlin

Berlin

DE

Headquarters, sound measurements, electronics development and system implementation

  • Sound level limiter SPB 422 / SPB 422T (in-house development)
  • Connection system LC 100 for central site-wide sound distribution (in-house development)

Products & Systems

Sound level limiter SPB 422
Sound level limiter SPB 422In-house development · Event technology
Media systems for event venues
Media systems for event venuesSystems engineering · Catering/Institutions

Inside the production

Lütronic Elektroakustik
Lütronic Elektroakustik
Sound measurements and level calibration
Sound measurements and level calibration
Media systems
Media systems
Electronics development
Electronics development
References and projects
References and projects

Industries

Event technologyCatering/Clubs and barsFestivals and major eventsSporting eventsMedical technologyEnergy infrastructureIndustrial/Control technology

Processes & technical limits

ProcessesToleranceMax. partWeightLot sizeMaterials
Hardware and software development for industrial, medical and control technologyEngineering–––––
Sound level limiter SPB 422 (in-house development, analogue signal path, latency-free)Engineering–––––
Sound measurements, level calibration, sound reports and measurement reportsTesting–––––
Planning, implementation and installation of sound, lighting, conference and sound systemsAssembly–––––

2 Anlagen & Maschinen

MachineManufacturer / modelQuantityWorking areaYear builtSite
Sound level limiter SPB 422 / SPB 422T (in-house development)Lütronic Elektroakustik SPB 422–––Berlin
Connection system for central site-wide sound distribution (in-house development)Lütronic Elektroakustik LC 100–––Berlin

Additional services

Sound measurements and noise measurementsSound reports and measurement reportsLevel calibration of sound systemsIntegration of sound level limitersSound forecasts and consulting on stage/loudspeaker positioningPlanning and implementation of sound, lighting and conference systemsAcoustic optimisation of event spacesCentral site-wide sound distribution (100 V network, in-house development LC 100)Streaming solutions for live broadcastsSpeaking-time control systems for conferences/panel discussionsHardware and software development (industrial, medical and control technology)

Reference customers

BVV Friedrichshain-KreuzbergBVV NeuköllnGroße Landesloge der Freimaurer von DeutschlandMoleculeOberhafenkantineTanzschule BroadwayTanzschule KellerTanzschule SeefeldtSpandauer WinterlandLichtenberger WinterzauberFamily WonderlandBerliner WintertraumArena BerlinBerghainClub der VisionäreRevier SüdostPaloma BarBerlinaleBucht der TräumerFestival of LightsKreuzberg-FestivalMellowJamPop-Kultur FestivalSkalar FestivalBeachMitteBerlin-MarathonHighway to HillVelo-City

Quality & Measurement Accuracy

Compliance with official requirements and the maximum sound levels determined by measurement is ensured through the use of sound level limiters or through sound measurements accompanying events. The SPB 422 evaluates signals simultaneously using the A and C weighting curves in accordance with DIN EN 61672-1.

EvidenceBerlin
DIN EN 61672-1 (frequency weighting SPB 422)

Company

  1. More than 40 years of experience in level calibration and noise limitation of sound systems

  2. More than 20 years of experience in the design and planning of electroacoustic systems

Personalised demo

Ready to see Amplifa Marketplace in action?

From a structured request to the right manufacturing partner: AI-assisted matching, verified suppliers and transparent metrics — in one place for industrial companies across the DACH region.

Request a demo